• Title/Summary/Keyword: indoor relative humidity

Search Result 207, Processing Time 0.026 seconds

Distribution of airborne microorganism in the feedstuff manufacture factory (사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구)

  • Kim, Ki-Youn;Jeong, Youn-Il;Kim, Chi-Nyon;Won, Jong-Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.335-342
    • /
    • 2007
  • The objective of the study is to investigate the distribution patterns of airborne bacteria and fungi in the feedstuff manufacture factory. The mean levels of airborne bacteria and fungi in the feedstuff manufacture factory were $113({\pm}18)cfu/m^3$ and $89({\pm}5)cfu/m^3$ for pelleting process and $198({\pm}5)cfu/m^3$ and $124({\pm}12)cfu/m^3$ for powdering process, respectively. The percentage of respirable and total concentration of airborne bacteria and fungi in the feedstuff manufacture factory ranged from 60% to 90% and were higher in pelleting process than powdering process. The ratio of indoor and outdoor airborne microorganism exceeded 1.0 regardless of types of feedstuff manufacture process. Based on the result of the study, there would be an association between environmental factors such as relative humidity and carbon dioxide and airborne microorganism's bioactivity.

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구)

  • Chung Min-Ho;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.

Numerical Simulation of the Thermal Environment inside an Opened Tomb (개방된 고분내부의 열 환경 수치모사)

  • Lee, Kum-Bae;Youn, Young-Muk;Jun, Hee-Ho;Park, Jin-Yang;Ko, Seok-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.872-878
    • /
    • 2006
  • In recent years the importance of the preservation of cultural artefacts like ancient tombs has been widely accepted domestically and internationally as the quality of life improves. However not much technical attention has been paid for the facilities and systems to preserve those artefacts. Even the general understanding of the preservatory environment of the underground space as tombs is poor. As a part of the present study, the temperature and relative humidity inside a selected artefact, Shinkwan-ri tomb, have been monitored for a year round by the present author to improve the understanding of the indoor thermal environment, is pursued to provide a predictive tool of numerical modelling of Shinkwan-ri tomb the opened underground space thermal environment. In this study, predictive numerical modelling of Shinkwan-ri tomb using the Computational Fluid Dynamics, calculate the velocity and temperature distribution and offer basic data which are necessary for the best fitted design of tomb air-conditioning device.

  • PDF

Fungal Distribution of the Janggyeong Panjeon, the Depositories for the Tripitaka Koreana Woodblocks in the Haeinsa Temple

  • Hong, Jin Young;Kim, Young Hee;Lee, Jeong Min;Kim, Soo Ji;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.38 no.1
    • /
    • pp.64-71
    • /
    • 2022
  • Many investigations have been conducted on the biological damage and environmental conditions necessary to preserve the Janggyeong Panjeon and Daejanggyeongpan (woodblocks). We performed a survey on the concentration and diversity of airborne fungi in the Janggyeong Panjeon and compared them with the results of a survey from 2012. The temperature of the Beopbojeon building was slightly lower, while the relative humidity was higher than those found at the Sudarajang building. The concentration of airborne fungi in the Beopbojeon was 1.44-fold that of the Sudarajang. It was confirmed that the concentration and diversity of airborne fungi in the Janggyeong Panjeon differed depending on the sampling site. In total, 23 fungal genera were identified from the air samples, and 11 fungal and 1 bacterial genera were identified from the surface of the woodblocks. Among these, only five types of fungi were commonly distributed in the indoor air and surface of the Daejanggyeongpan; however, 58.3% of the fungi identified on the surface of the woodblocks were not observed in the in the air samples. The surface-dwelling fungi may accumulate dust to form microbial communities over time.

Seasoning of Commercial Wood Using Solar Energy (태양에너지를 이용한 유용목재의 건조)

  • Jung, Hee-Suk;Lee, Hyoung-Woo;Lee, Nam-Ho;Lee, Sang-Bong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.10-39
    • /
    • 1988
  • This study investigated the temperatures and relative humidities in the semi-greenhouse type solar dryer with a black rock-bed heat storage and without heat storage and outdoor temperature and relative humidity at 9 a.m. and 2 p.m.. A comparison was made of the drying rates, final moisture contents, moisture content distributions, casehardening stresses, drying defects, volumetric shrinkage of dried lumber for solar- and air-drying from the green condition of mixtures of Douglas-fir, lauan, taun, oak and sycamore 25mm- and 50 mm-thick lumber during the same period for four seasons, and heat efficiencies for solar dryer with and without the heat storage for saving of heat energy and the cost of lumber drying using the solar energy. The results from this study were summarized as follows: I. The mean weekly temperatures in the solar dryers were 3 to $6^{\circ}C$ at 9 a.m. and 9 to $13^{\circ}C$ at 2 p.m. higher than mean outdoor temperature during all the drying period. 2. The mean weekly relative humidities in the solar dryers were about 1 to 19% at 9 a.m. higher than the outdoor relative humidity. and the difference between indoor and outdoor relative humidity in the morning was greater than in the afternoon. 3. The temperatures and relative humidities in the solar dryer with and without the heat storage were nearly same. 4. The overall solar insolation during the spring months was highest and then was greater in the order of summer, atumm, and winter month. S. The initial rate of solar drying was more rapid than that of air drying. As moisture content decreased, solar drying rate became more rapid than that of air drying. The rates of solar drying with and without heat storage were nearly same. The drying rate of Douglas-fir was fastest and then faster in the order of sycamore, lauan, taun and oak. and the faster drying rate of species, the smaller differences of drying rates between thicknesses of lumber. The drying rates were fastest in the summer and slowest in the winter. The rates of solar drying during the spring were more slowly in the early stage and faster in the later stage than those during the autumn. 6. The final moisture contents were above 15% for 25mm-thick air dried and about 10% for solar dried lumber, but the mean final MCs for 50mm-thick lumber were much higher than those of thin lumber. The differences of final MC between upper and lower course of pile for solar drying were greater than those of pile for air drying. The differences of moisture content between the shell and the core of air dried lumbers were greater than those of solar dried lumber, smallest in the drying during summer and greatest in the drying during winter among seasons. 7. Casehardening stresses of 25mm- and 50mm-thick dried lumber were slight, casehardening stress of solar dried lumber was severer than that of air dried lumber and was similar between solar dried lumber with and without heat storage, Casehardening stresses of lumber dried during spring were slightest and then slighter in the order of summer, autumn, and winter. Casehardening stresses of Douglas -fir, sycamore and lauan were slight, comparing with those of taun and oak. 8. Maximum initial checks of 25mm-thick lumber occurred above and below fiber saturation point and those of 50mm-thick lumber occurred in the higher moisture content than thin lumber. As the moisture content decreased, most of checks were closed and didn't show distinct difference of the degree of checks among drying methods. The degree of checks were very slight in case of Douglas-fir and lauan, and severe in case of taun and oak. The degree of checks for 50mm-thick lumber were severer than those for 25mm-thick lumber. 9. The degree of warpage showed severe in case of oak and sycamore lumber, but no warping was found in case of Douglas-fir, lauan and taun. 10. The volumetric shrinkages of taun and oak were large and medium in case of Douglas-fir, lauan and sycamore. 11. Heat efficiencies of solar dryer with heat storage were 6.9% during spring, 7.7% during summer, 12.1% during autumn and 4.1% during winter season. Heat efficiency of solar dryer with heat storage was slightly greater than that of without heat storage. As moisture content of lumber decreased, heat efficiency decreased.

  • PDF

Detailed Deterioration Evaluation and Analysis of Conservation Environment for the Seosanmaaesamjonbulsang (Rock-carved Triad Buddha in Seosan), Korea (서산마애삼존불상의 정밀 손상도 평가와 보존환경 분석)

  • Lee, Sun-Myung;Lee, Chan-Hee;Kim, Ji-Young
    • Journal of Conservation Science
    • /
    • v.26 no.3
    • /
    • pp.277-294
    • /
    • 2010
  • The Seosanmaaesamjonbulsang (National Treasure No. 84) consists of light gray and coarse to mediumgrained biotite granite with partly developed pegmatite and quartz vein. The host rock is divided into dozens of rock blocks with various shape along irregular discontinuity plane. The evaluation results of discontinuity systems reveal that the host rock were exposed to instable sloping environments. Results of deterioration diagnosis show that the degree of damage has been made worse by physical weathering and surface discoloration laying stress on part that vertical and horizontal joints are massed. Generally, deterioration rate of the triad Buddha surface cover with 42.7%, however, the rate of physical weathering and surface discoloration are subdivided to 9.6% and 33.1%, respectively. Ultrasonic measurements indicate that the triad Buddha was reached highly weathered grade in general. And the rock material was weaken to show low velocity zone of 1,000m/s along irregular joint systems. Indoor and outdoor mean relative humidity of the shelter was recorded more than 70% during every season, and high frequency appears in high relative humidity range over 95%. Such environments seem to have produced dew condensation on the rock surface with rainfall and supply water, promoted physical, chemical and biological weathering along crack and joint, resulting in high permeation of water and percentage of water content. Therefore, it is judged that for scientific conservation of the triad Buddha it needs environment control through persistent preservation environment monitoring including water problem.

Environment in Apartment Verandas at Three Floors, and Change in Growth of Selected Ornamental Plants under Simulated Light Intensities (아파트 베란다 층별 기상환경 측정과 이에 따른 모의 광도가 오색마삭줄과 피토니아의 생육에 미치는 영향)

  • Son, Moon-Sook;Song, Ju-Yeon;Jeong, Byoung-Ryong
    • Journal of agriculture & life science
    • /
    • v.45 no.3
    • /
    • pp.43-51
    • /
    • 2011
  • This project was conducted to measure actual temperature, relative humidity (RH), and light intensity at different apartment floors and to suggest suitable indoor plants by investigating morphological changes of Treophelosparmum asiatioum and Fittonia verchaffeltii var. argyroneura as affected by light intensity. Temperature and RH in apartment verandas were measured in three different (2nd, 9th, and 16th) floors on three different buildings for 30 days seasonally. The light intensity, temperature, and RH were recorded outside (parking area) and inside apartment verandas for 24 hours on a selected sunny summer day (between Aug. 19 and Sept. 14, 2008). Based on the first study, we investigated effect of simulated light intensity (40, 70, 100, and $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) on changes in growth and development of T. asiatioum and F. verchaffeltii var. argyroneurain growth chambers. However, daily mean light intensity of 2nd, 9th, and 16th floors was different each other as it was about 40, 70, and $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. In the growth chamber experiment, plant height, internode length, and leaf length and width were not affected significantly by light intensity, but changes in leaf color were apparent in the new leaves with the increasing light intensity. The results suggest that T. asiatioum could be best fit to high, and F. verchaffeltii var. argyroneura to lower floor verandas, considering their aesthetic values.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Analysis of Hygrothermal Performance for Standard Wood-frame Structures in Korea (국내 농어촌 표준 목조주택의 hygrothermal 성능 분석)

  • Chang, Seong Jin;Kang, Yujin;Wi, Seunghwan;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.440-448
    • /
    • 2016
  • As recent buildings become more air tight, the natural ventilation rate is significantly reduced and it leads to difficulty in removing accumulated moisture in buildings. Hot and humid weather in summer and the large amount of moisture caused by indoor activity are the major factors of moisture problem in Korea. The hygrothermal behavior of building environment has to be considered carefully to reduce condensation risk and mold growth potential, and comfortable indoor environment. In this study, we evaluated hygrothermal behavior of Standard Wood-frame Structure published in the Korea Rural Community Corporation Using WUFI simulation program. The results indicated that the total water contents of wood wall measured in 2014 was lower than wood wall in 2010. As a result of evaluation by separating the farming and fishing areas, Moisture problems in fishing area became larger. The walls had a significant impact on the relative humidity than the temperature each areas. Furthermore, excessive water content problem of the wood-based material was reduced in the wall that could be applied in the fishing villages by changing the outdoor finishing materials. And Mold growth risk on the interior materials could be removed through the different setting of the indoor temperature during summertime.