• 제목/요약/키워드: indoor radon

검색결과 157건 처리시간 0.036초

Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon

  • Joseph Emmanuel Ndjana Nkoulou II;Louis Ngoa Engola;Guy Blanchard Dallou;Saidou;Daniel Bongue;Masahiro Hosoda;Moise Godefroy Kwato Njock;Shinji Tokonami
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.59-67
    • /
    • 2023
  • Background: This study aims to reevaluate natural radiation exposure, following up on our previous study conducted in 2019, and to assess the associated risk of lung cancer to the public residing in the gold mining areas of Betare-Oya, east Cameroon, and its vicinity. Materials and Methods: Gamma-ray spectra collected using a 7.62 cm×7.62 cm in NaI(Tl) scintillation spectrometer during a car-borne survey, in situ measurements and laboratory measurements performed in previous studies were used to determine the outdoor absorbed dose rate in air to evaluate the annual external dose inhaled by the public. For determining internal exposure, radon gas concentrations were measured and used to estimate the inhalation dose while considering the inhalation of radon and its decay products. Results and Discussion: The mean value of the laboratory-measured outdoor gamma dose rate was 47 nGy/hr, which agrees with our previous results (44 nGy/hr) recorded through direct measurements (in situ and car-borne survey). The resulting annual external dose (0.29±0.09 mSv/yr) obtained is similar to that of the previous study (0.33±0.03 mSv/yr). The total inhalation dose resulting from radon isotopes and their decay products ranged between 1.96 and 9.63 mSv/yr with an arithmetic mean of 3.95±1.65 mSv/yr. The resulting excess lung cancer risk was estimated; it ranged from 62 to 216 excess deaths per million persons per year (MPY), 81 to 243 excess deaths per MPY, or 135 excess deaths per MPY, based on whether risk factors reported by the U.S. Environmental Protection Agency, United Nations Scientific Committee on the effects of Atomic Radiation, or International Commission on Radiological Protection were used, respectively. These values are more than double the world average values reported by the same agencies. Conclusion: There is an elevated level of risk of lung cancer from indoor radon in locations close to the Betare-Oya gold mining region in east Cameroon. Therefore, educating the public on the harmful effects of radon exposure and considering some remedial actions for protection against radon and its progenies is necessary.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권1호
    • /
    • pp.117-124
    • /
    • 2020
  • 본 연구는 실내공기질의 실시간 농도변화 분석을 통하여 일시적으로 기준값을 초과하는 항목에 대하여 원인 분석을 통하여 요양원의 쾌적한 실내공기질을 유지하기 위한 방안을 제안하고자 실시하였다. 요양원에서 미세먼지(PM10), 이산화탄소(CO2), 일산화탄소(CO), 휘발성유기화합물(VOC), 라돈(Radon) 등 5개 항목에 대하여 다목적 홀에서 봄(4월), 가을(9월)에 각1회 측정을 실시한 결과 측정 항목 모두 실내공기질 관리법에서 정한 기준을 만족하는 것으로 분석되었다. 실시간 농도 변화에 대한 분석 결과 병실의 경우 이산화탄소의 농도가 재실자 수에 의하여 기준치에 근접하는 수준을 보였으며 다목적 홀의 경우 이산화탄소 및 미세먼지는 주간보호 대상 어르신 및 근무자의 프로그램 활동과 휘발성유기화합물의 경우 식탁을 소독하기 위하여 사용하는 소독제(알코올) 및 만들기, 색칠하기 등의 프로그램 운용시 사용되는 보조도구(접착제)로 인하여 일시적으로 기준치를 초과하는 것으로 분석되었다. 결국 측정 대상 요양원에서는 온열환경을 고려하여 주기적인 환기, 천연소독제 사용 및 친환경 접착제 사용 등을 실시한다면 쾌적한 실내공기질 제공이 가능하고 요양원의 경쟁력 확보에도 기여할 것으로 판단된다.

홍콩지하철의 실내공기질 개선사례 연구 (Case Study of Hong Kong Metro for Improving Indoor Air Quality)

  • 권순박;조영민;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1561-1565
    • /
    • 2008
  • More than 3.4 million people use Hong Kong metro a day. It was first constructed in 1979, and extended to 9 operating lines with 168.1km length operated by Hong Kong Mass Transit Railway Corporation (MTR). In Hong Kong, airborne viruses such as avian influenza (bird's flu) and severe acute respiratory syndrome (SARS), air pollution by high-density traffics, bacteria and mold due to relatively high humidity are major concerns on air quality management. In this study, we focused on the cases for improving indoor air quality conducted by Hong Kong MTR currently. The case includes the photocatalytic coatings on knobs (or hand straps) to prevent outbreak of bird's flu and SARS, the high voltage ionizers installed at metro platform, and the periodical radon monitoring.

  • PDF

라돈 환경계통의 제어 매개변수 모델링 (Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters)

  • 주운표;김건중;장시영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

국내 일부학교 건축물의 실내공기질 평가 (The Assessment of Survey on the Indoor Air Quality at Schools in Korea)

  • 손종렬;노영만;손부순
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

한국인의 실내 라돈-222 자핵종 피폭으로 인한 초과 폐암위험 (Evaluation of Excess Lung Cancer Risk in Korean due to Indoor Exposure to Natural $^{222}Rn$ Progenies)

  • 장시영;하정우;이병헌
    • Journal of Radiation Protection and Research
    • /
    • 제17권1호
    • /
    • pp.57-70
    • /
    • 1992
  • 실내 라돈-222 자핵종의 농도에 피폭되므로서 유발될 수 있는 한국인의 초과 폐암위험을 방사선피폭의 확율론적 위험예측 모형을 이용하여 정량적으로 평가하였다. 1989년 기준 표준 생명표와 사망원인 통계연보 자료로부터 유도한 한국인의 폐암 사망률은 남, 여별로 각각 $22.4/10^5-$년 및 $9.5^/10^5-$년으로 추정 되었다. 이 폐암 사망율을 근거로 수학적으로 예상한 한 모든 사망원인하의 기저 폐암사망위험은 남, 여별로 각각 0.047(4.7%) 및 0.019(1.9%)로 1984년도 미국의 0.067(6.7%) 및 0.025(2.5%)보다 낮았다. 방사선 피폭의 확률론적 수정 상대위험 예측모형을 사용하여 예상한 한국인의 라돈자핵종 피폭당의 초과 폐암위험 계수는 남자 : 0.022/WLM, 여자 : 0.009/WLM 및 평균 : 0.017/WLM로 나타났으며 이로부터 추정한 한국인의 평균 수명중 라돈자핵종 피폭유발 초과 폐암의 사망빈도는 $230/10^6$인-WLM으로 최근 외국의 관련연구에서 보고한 $120{\sim}450/10^6-WLM$의 거의 중간치(median)정도에 해당하는 것으로 평가되었다.

  • PDF

가계의 이질적 선호가 비시장재 가치의 추정에 미치는 영향 (The Effect of Heterogeneous Preference on Non-market Valuation)

  • 김용주
    • 자원ㆍ환경경제연구
    • /
    • 제16권4호
    • /
    • pp.873-900
    • /
    • 2007
  • 비시장재의 가치를 추정하는 많은 연구들은 비시장재에 대한 선호가 모든 경제주체에 있어서 동질적이라고 가정한다. 그러나 현실적으로 비시장재에 대한 선호가 경제주체마다 다를 수 있기 때문에 경제주체간 선호의 이질성을 가정하는 것이 합리적이며 가치추정의 편의를 감소시키게 될 것이다. 본 연구는 방사성 오염 물질인 라돈 가스 농도의 저감에 대한 선호와 도로교통 및 원자력발전의 안전에 대한 선호가 각각 가계들 사이에 이질적일 것인지, 그리고 가계들의 선호가 동질적임을 가정하는 경우에 비해 모형 및 비시장재 가치 추정에 어떠한 영향을 미치는지 분석하였다. 속성가치선택법(choice experiments)과 중첩로짓(mixed logit) 모형을 이용한 결과, 이질적 선호를 허용하는 것이 이를 배제하는 것보다 설명력 있는 모형을 가져다 주었다. 그리고 라돈 농도 저감 및 도로교통 안전 각각에 대하여 이질적 선호가 가계들 사이에 뚜렷이 존재하는 것으로 나타났다. 그러나 원자력발전 안전에 대한 선호의 이질성은 뚜렷이 존재하지 않았다. 이질적 선호를 배제하는 경우와 비교할 때 이를 허용하는 경우의 지불의사액은 라돈 농도 저감의 경우에 평균 2.44배 증가하였으며, 도로교통 안전의 경우에는 1.74배 증가하였다.

  • PDF

커피 찌꺼기 혼합물을 활용한 라돈 저감 효과 분석 (Analysis of Radon Reduction Effect Using Coffee Waste Mixture)

  • 제재용;김경민;김율민;이현우;박지우
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.855-860
    • /
    • 2021
  • 커피는 국내뿐만 아니라 전 세계인들에게 인기 있는 음료로서 그 소비는 점점 늘어나는 추세에 있다. 커피 소비 증가는 커피를 추출하고 발생되는 커피 찌꺼기 또한 증가하고 있으며, 다양한 분야로 재활용을 시도하고 있다. 그러나 이러한 재활용 방법들은 재활용 과정들이 복잡하고 전문적인 기술을 필요로 한다. 하지만 본 연구에서는 커피 찌꺼기, 한천분말, 가루풀을 적정 비율로 배합하여 시멘트 건축마감 재료로 활용하였다. 본 재활용 방법은 제조 방법이 간단하고 시멘트벽에서 방출되는 라돈을 1회 바름으로 2.5시간, 2회 바름으로 3.9시간을 지연시켜 실내 공기질을 향상시킬 수 있는 것으로 나타났다. 또한 커피 찌꺼기 혼합물을 바른 후 건조과정에서 발생하는 균열을 매우기 위하여 2회 바름으로서 미관적인 완성도와 벽면에서 커피 찌꺼기가 탈락되는 것을 방지할 수 있는 것으로 나타났다.

의료기관 맞춤형 실내 공기 모니터링 IoT 시스템 연구 (A Study of Indoor Air Monitoring IoT System Customized for Medical Institutions)

  • 이효승;오재철
    • 한국전자통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.1217-1222
    • /
    • 2020
  • 현재 우리나라를 포함하여 전 세계적으로 환경오염에 관한 연구가 지속으로 진행되고 있으며 그중에서도 다수의 사용자가 이용하는 다양한 시설의 실내 공기를 청정하게 유지, 관리하여 국가적으로 국민의 건강과 환경오염을 예방하기 위해 관련 법령을 시행 등 다양한 노력 들이 이루어지고 있다. 특히 의료기관의 경우 방문하는 다수의 사람이 질환이나 질병을 갖고 있으며 실내 공기 오염과 관련하여 두통, 우울증, 신경과민, 심장병, 암 등의 만성질환에 유의한 영향을 미칠 수 있음이 시사되고 있다. 이러한 상황을 고려하여 본 논문에서는 의료기관에 적용하기 위한 실내 공기 모니터링 IoT 시스템을 통해 공기 오염도에 대한 중앙 모니터링 및 담당자 자동 호출 기능 등을 제공하여 재실자에게 쾌적하고 청정한 실내 환경을 제공할 수 있기를 기대한다.

전주시 공동주택 지하주차장의 실내환경 개선에 관한 연구 (A Study on the Improvement of Indoor Environment in the Underground Parking Lot of Apartments in Jeonju City)

  • 정재연;정인수;포위
    • 한국농촌건축학회논문집
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2020
  • The main purpose of the research is to prevent residents who are using underground parking lot from being exposed to pollusion, and to allow them to enjoy clean indoor environment. The study subject for the research are underground parking lots in 20 different apartments, 4 of them were constructed before 2000, 10 were constructed from 2000-2010, and the rest were constructed after 2010. By analyzing the air quality in these underground parking lots, we found out that O3, NO2, CO, PM10, Radon in all parking lots were not excessive compared to the standard limit. TVOC rate was measured with the value in between 312 ~ 2,137㎍/m3, with CO2 value in between 193~1,824 ppm, and HCHO with the value in between 0.01~1.52ppm. The lightning system in underground parking lots in apartments constructed before 2000 were using manual light control system, while automatic light control system was used in all apartments constructed after 2000, and the brightness of parking lots in apartments constructed before 2000 was quite low. The apartments constructed after 2000 are performing cleaning and ventilation due to management agreement, while the apartments constructed before 2000 are not performing regular cleaning and there was no mechanical ventilation system installed. The difference of indoor air quality was significant seasonally, daily, and yearly (year of construction), while illuminance was significantly different yearly.