• Title/Summary/Keyword: indoor model test

Search Result 111, Processing Time 0.028 seconds

An Experimental Study on the Detection of Loosened Areas in a Ground cavity Using a Micro Penetration Test (초소형 관입시험기를 이용한 지반공동 주변지반의 이완영역탐지를 위한 실험적 연구)

  • Kim, Ho-Youn;Kim, Young-Ho;Park, Yoon-Suk;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.299-306
    • /
    • 2019
  • In this study, a model experiment that simulates the behaviour of the ground composed of several compacted layer was intended to measure the loosened area in the event of a ground cavity through a LAD (Loosened area detector). It was confirmed that the size of the cone diameter was affected by the ground composed of fine grain + granulated soil layered through the model soil. In order to select the appropriate cone type, a scale effect experiment was conducted. From the test results, a micro-cone was chosen for the most suitable indoor model experiment. In the case of applying LAD in this study, the loosening condition of the ground was determined by the rapid change in penetration resistance caused by the difference in the boundary surface and relative density due to the compaction of the ground for indoor model testing. The range of loosened area occurring in the cavity was estimated through the penetration resistance characteristics on the ground, and the failure area was identified through the reduction rate of penetration resistance in the loosening area.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Reliability Analysis of Degradation Data for LEDs (LED 열화데이터의 신뢰성 분석)

  • Park, Chang-Kyu
    • Journal of Applied Reliability
    • /
    • v.9 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF

The Types of Housing Life-Style and Preferences of the Internal and External Space of Multi-Family Housing (주생활양식 유형과 공동주택내부.외부공간의 선호에 관한 연구)

  • 김미희;이유미
    • Journal of the Korean housing association
    • /
    • v.9 no.2
    • /
    • pp.89-96
    • /
    • 1998
  • This study has been designed to explore how the types of housing life-style relate to the preferences of internal and external spaces among multi-family housing residents. Data were collected by questionnaire self-administered to 278 female residents living in multi-family housing over 20s pyong (66$m^2$) in the Kwangju area. General linear model/Duncan-test, and $x^2$-test were used in analyzing the data. In the preferences of internal space, there were significant differences in the needs of an indoor garden, exercise spaces, and a front balcony and in the concept of the living room and the dining-kitchen by types of housing life-style. In the preferences of external spaces, there were significant difference in the preferred type of housing, the preferred residential area, and in the need of an individual storage space and a walking path by types of housing life-style.

  • PDF

Optical Wireless Remote Control Using Indoor LED Lightings (LED 실내조명을 이용한 광무선 원격제어)

  • Sohn, Kyung-Rak;Sohn, Chang-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1111-1116
    • /
    • 2012
  • At present, indoor optical wireless communications using LED lightings has been widely studied. The combination of this technology to the low voltage powerline grid installed in each home makes an efficient method for fulfilling the premise of broadband access for home networking. In this paper, white LEDs were used for both illumination and remote-control, so that information can be broadcast within a room for control the optical wireless systems. We implemented a model car to evaluate the performance of optical wireless remote-control. The requirement for levels of illumination suitable for communication were investigated and applied to design the test-bed. In spite of limitation of line-of-sight communications, it will open up new applications to the optical wireless remote control system in an electromagnetic interference region.

An Investigation into the Building's Thermal Mass Effect on the Variation of Indoor Temperature (건물의 축열질량이 실내기온 변화에 미치는 영향 평가)

  • Chun, Won-Gee;Jeon, Myung-Seok
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.72-80
    • /
    • 1992
  • This paper is concerned with the accurate estimation of the thermal mass effect on the variation of indoor temperature for residential buildings. To carry out the analysis here, the method called "PSTAR(Primary and Secondary Terms Analysis and Renormalization)" has been extensively used. This method was originally developed by the National Renewable Energy Laboratory(NREL) in the United States. The test results reported here represent two extreme cases of the interior thermal mass, which demonstrate its effect on the interior thermal environment as well as on the overall thermal behavior of the building structure. The monthly heating and cooling loads are also extrapolated by using the renormalized model, which are crucial in designing and refurbishing HVAC systems for the building.

  • PDF

A Study of the Development of a Modular, Lightweight Steel Ceiling System (유닛형 경량철골 천정시스템 개발에 관한 연구)

  • Kim, Hyeyeon;Bae, Sanghwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.269-277
    • /
    • 2017
  • This study consists of an analysis of pre-existing ceiling construction systems as well as the development of a replacement unitary, lightweight steel ceiling system and related legal standards. Based on the material conditions and progression of the study, appropriate components were chosen and details were modified by mock-up test. A final study model was evaluated for performance and adaptability based on four parameters (indoor environment, constructability, budget economy, and aesthetics) and compared to the pre-existing ceiling system. As a result of the initial study, a lightweight steel design was created consisting of a reinforced structure with modular bars and entry holes for components. This system was hung directly on the suspension structure. The new design increased lighting and acoustic performance adapted to an indoor environment. Moreover, the speed of construction was increased by approximately 30%, the cost was decreased by approximately 20%, and ceiling aesthetics were improved.

A study on the Development of Vertical Air Temperature Distribution Model in Atrium (아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구)

  • Kim, Y.I.;Cho, K.H.;Kim, K.W.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

Design and Implementation of Fire Detection System Using New Model Mixing

  • Gao, Gao;Lee, SangHyun
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.260-267
    • /
    • 2021
  • In this paper, we intend to use a new mixed model of YoloV5 and DeepSort. For fire detection, we want to increase the accuracy by automatically extracting the characteristics of the flame in the image from the training data and using it. In addition, the high false alarm rate, which is a problem of fire detection, is to be solved by using this new mixed model. To confirm the results of this paper, we tested indoors and outdoors, respectively. Looking at the indoor test results, the accuracy of YoloV5 was 75% at 253Frame and 77% at 527Frame, and the YoloV5+DeepSort model showed the same accuracy at 75% at 253 frames and 77% at 527 frames. However, it was confirmed that the smoke and fire detection errors that appeared in YoloV5 disappeared. In addition, as a result of outdoor testing, the YoloV5 model had an accuracy of 75% in detecting fire, but an error in detecting a human face as smoke appeared. However, as a result of applying the YoloV5+DeepSort model, it appeared the same as YoloV5 with an accuracy of 75%, but it was confirmed that the false positive phenomenon disappeared.

Design Study of Ionic Flyers (신 개념 이온 비행체의 설계 연구)

  • Lee, Ji-Hong;Joo, Sang-Hyun;Kim, Dae-Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.3 no.1
    • /
    • pp.52-57
    • /
    • 2008
  • A completely new flying machine is developed and the details for practical implementation is suggested. The proposed machine contains no moving parts so that it can be operated in noiseless manner. This paper presents some operational principles of the flying machine as well as the overall process of designing the basic ionic flyer model. The validation of the model is checked by experiments of test flights. Also, two conceptual design results for practical implementation are introduced with the derivation of design parameters. The application field is expected to include indoor secrete surveillance as well as ion propulsion.

  • PDF