• 제목/요약/키워드: indoor environmental quality

검색결과 533건 처리시간 0.032초

몽골 울란바토르 시 전통 주거공간의 실내공기 오염 기초조사 (Indoor air pollution in ger, a traditional type of residence in Mongolia)

  • 이보람;;;이기영
    • 한국환경보건학회지
    • /
    • 제42권2호
    • /
    • pp.118-125
    • /
    • 2016
  • Objectives: The traditional type of residence in used in Mongolia, called a ger, is an important residential form and applies coal combustion for cooking and heating. The combustion of coal in ger is the major source of indoor air pollution. The purposes of this study were to measure indoor air pollution in ger and determine the effect of cooking and heating activities. Methods: Indoor temperature, relative humidity, particulate matter less than $2.5{\mu}m$ ($PM_{2.5}$) and black carbon (BC) were continuously measured for 24 hours in eight ger. The measurements were conducted in January or February 2015. Heavy metals in $PM_{2.5}$ filter samples were analyzed by ICP-MS. Results: Average indoor temperature and relative humidity were $19.6{\pm}4.6^{\circ}C$ and $21.4{\pm}5.2%$, respectively. The average indoor $PM_{2.5}$ concentration in the eight ger was $119.8{\mu}g/m^3$ and ranged from 69.4 to $202.7{\mu}g/m^3$. The peak concentrations of $PM_{2.5}$ and BC during cooking and heating periods were several times higher than the 24- hour average concentration. Conclusion: The major contributor to indoor $PM_{2.5}$ and BC concentrations in the ger was coal combustion for cooking and heating.

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인 (Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces)

  • 박희은;박정호;김형갑
    • 한국산업보건학회지
    • /
    • 제22권2호
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

서울시 일부 학교의 실내 공기질 조사 및 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul)

  • 손종렬;변상훈;김영환;김종혁;조윤수;이재영;박윤주
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

챔버를 이용한 객실 이산화탄소 흡착 연구 (Study on Adsorption of Carbon Dioxide in Cabin Using Chamber)

  • 조영민;이지윤;최진식;권순박;박덕신;김희만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1309-1314
    • /
    • 2011
  • People spend approximately 80 ~ 90 % of their time in various kinds of indoor spaces. And, in metropolitan area, most people spend more than 1 hour in public transportation everyday. For this reason, people's interest in the indoor air quality is drastically increasing. Among various indoor air pollutants, $CO_2$ is one of the most severe environmental concerns. Ventilation is commonly used to keep low $CO_2$ concentration in the passenger cabin. However, ventilation may worse the indoor air quality problem in case of subway because the tunnel is seriously polluted by particulate matters. In this study, an alternative way to remove $CO_2$ was suggested. The adsorption of $CO_2$ by $CO_2$ adsorbent was studied. Zeolite modified with base was prepared, and $CO_2$ removal performance was tested in $4m^3$ and $24m^3$ environmental chambers. It was found that $CO_2$ adsorbent could effectively remove $CO_2$ in the chambers.

  • PDF

거주지역 실내공기 특성 및 이산화질소 노출에 관한 연구 (Residence s Exposure to Nitrogen Dioxide and Indoor Air Characteristics)

  • 양원호;배현주;정문호
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.183-192
    • /
    • 2002
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level and so on. Although technologies exist to measure these factors directly, direct measurements of all factors are impractical in most field studies. The purpose of this study was to develop an alternative methods to estimate these factors by multiple measurements. Daily indoor and outdoor NO$_2$concentrations for 21 days in 20 houses in summer and winter, Seoul. Using a mass balance model and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor(emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the ventilation and source strength were estimated. During sampling period, geometric mean of natural ventilation was estimated to be 1.10$\pm$1.53 ACH, assuming a residential NO$_2$decay rate of 0.8 hr$^{-1}$ in summer. In winter, natural ventilation was 0.75$\pm$1.31 ACH. And mean source strengths in summer and winter were 14.8ppb/hr and 22.4ppb/hr, respectively. Although the method showed similar finding previous studies, the study did not measure ACH or the source strength of the house directly. As validation of natural ventilations, infiltrations were measured with $CO_2$tracer gas in 18 houses. Relationship between ventilation and infiltration was statistically correlated (Pearson r=0.63, p=0.02).

환기가 불량한 실내공간에서, 담배연기에 의한 CO, $CO_2$, TVOC 및 에어로졸의 변화 (Changes of CO, $CO_2$, TVOC and Aerosol of Tobacco Smoke in a Poorly-Ventilated Indoor)

  • 한돈희;박수진;류지혜
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.132-139
    • /
    • 2006
  • Number of aerosol, CO, $CO_2$ and TVOC after one-, two-, three-cigarettes smoking were monitored with time every 10 minute for 180 minutes in the seminar room (volume $51.1m^3$) when poorly-ventilated. IAQ monitor (IAQRAE, model PGM-5210) and PortCount (TSI, model 8020) were used for monitoring. Aerosol was decreased with exponential decay equation and it was estimated that number of aerosol would be long suspended (one cigarette 75/cc. two cigarettes 66/cc, three cigarettes 141/cc by 8hrs after smoking). While CO was also decreased with exponential or linear decay equation and correlated with number of aerosol strongly, TVOC and $CO_2$ were increased with linear equation in accordance with time lag. Most of TVOC and $CO_2$ were above standard levels of Korean Indoor Air Quality (Ministry of Environment) without regarding number of cigarettes. When naturally ventilated, all of CO, $CO_2$ and TVOC concentrations were dramatically decreased below standard levels of Korean Indoor Air Quality.

실내 포름알데히드 농도에 미치는 식물의 영향 (Plant Effects on Indoor Formaldehyde Concentration)

  • 박소영;성기준
    • 한국환경과학회지
    • /
    • 제16권2호
    • /
    • pp.197-202
    • /
    • 2007
  • Formaldehyde is a typical indoor air pollutant that has numerous adverse health problems in modern living conditions. Phytoremediation that use plants to remove contaminants from polluted media can be applied to improve indoor air quality. Two sets of experiments; 1) two rooms in newly built auditorium and 2) a bed room in 2-year-old apartment; were performed to investigate plant effects on indoor formaldehyde concentration. It was observed from the experiments that plant can help decontaminating formaldehyde at low concentration level (0.1 ppm) but the effects decreased considerably at hish concentration (1ppm). The purification effects of indoor plant also showed the periodic pattern due to its physiological activity. More purification was observed as increasing plant density in the bed room but the formaldehyde concentration returned the original concentration level in two days after removing plants. It was suggested from the results that air purification using plants is an effective means of reduction on indoor formaldehyde level, though, reduction of source is highly desirable when the concentration level is high. The results also suggest that introducing supplementary purifying aids and/or efficient ventilation could be considered due to periodic removal pattern of plant.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Sick House/ Building Syndrome in Japan - Current Status and Practical Research on Indoor Air Quality -

  • Sekine, Yoshika
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.143-167
    • /
    • 2005
  • Many Japanese today are suffering from health disorders related to their living environment, such as allergies and hypersensitivity to chemical substances. The Sick House/Building Syndrome has been a serious problem since 1996, due to low level exposure to hazardous chemicals such as formaldehyde and volatile organic compounds (VOCs) emitted in airtight houses. This paper aims to show current status of the syndrome in Japan and practical researches to promote prevention of, and improvement to indoor air pollution due to chemicals.

  • PDF