Browse > Article

Changes of CO, $CO_2$, TVOC and Aerosol of Tobacco Smoke in a Poorly-Ventilated Indoor  

Han Don-Hee (Department of Occupational Health and Safety Engineering, Inje University)
Park Soo-Jin (Department of Occupational Health and Safety Engineering, Inje University)
Ryu Ji-Hye (Department of Occupational Health and Safety Engineering, Inje University)
Publication Information
Journal of Environmental Health Sciences / v.32, no.2, 2006 , pp. 132-139 More about this Journal
Abstract
Number of aerosol, CO, $CO_2$ and TVOC after one-, two-, three-cigarettes smoking were monitored with time every 10 minute for 180 minutes in the seminar room (volume $51.1m^3$) when poorly-ventilated. IAQ monitor (IAQRAE, model PGM-5210) and PortCount (TSI, model 8020) were used for monitoring. Aerosol was decreased with exponential decay equation and it was estimated that number of aerosol would be long suspended (one cigarette 75/cc. two cigarettes 66/cc, three cigarettes 141/cc by 8hrs after smoking). While CO was also decreased with exponential or linear decay equation and correlated with number of aerosol strongly, TVOC and $CO_2$ were increased with linear equation in accordance with time lag. Most of TVOC and $CO_2$ were above standard levels of Korean Indoor Air Quality (Ministry of Environment) without regarding number of cigarettes. When naturally ventilated, all of CO, $CO_2$ and TVOC concentrations were dramatically decreased below standard levels of Korean Indoor Air Quality.
Keywords
indoor; tobacco smoke; aerosol; CO; $CO_2$; TVOC;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 박동욱, 윤경섭, 박수택, 하권철 : 서울 일부 지하철 객차와 승강장에서 측정한 $PM_{10}과\;PM_{2.5}$ 농도의 특성. 한국환경보건학회지, 31(1), 39-46, 2005   과학기술학회마을
2 곽현석, 진구원, 김 원, 양원수, 최상준, 박동욱 : 서울 일부 지하철 승무원석의 PM, 이산화탄소, 일산화탄소 모니터링에 의한 실내공기질 특성 평가. 한국환경보건학회지, 31(5), 379-386, 2005   과학기술학회마을
3 Junker, M. H., Danuser, B., Monn, C. and Koller, T. : Acute sensory responses of nonsmokers at very low environmental tobacco smoke concentrations in controlled laboratory settings. Environmental Health Perspectives, 109(10), 1045-1052, 2001   DOI
4 조성준 : 식당 종업원의 환경 담배 연기(ETS)의 노출과 머리카락 중 생체지표 연구. 한국환경독성한회지, 19(2), 169-176, 2004
5 SPSS Inc. : $SigmaPlot^{\circledR)$ 8.0.2, SPSS Inc., Chicago, IL, 2002
6 TSI : Manual of Portacount Respirator Fit Test and N95 Companion, TSI incorporated, 2005
7 백성옥, 박상곤 : 도시지역 사무실내 공기 중 환경담배연기의 측정-흡연이 부유먼지 농도에 미치는 영향을 중심으로-. 한국대기환경학회지, 20(6), 715-727, 2004
8 Jo W-K, Oh J-W: Evaluation of CO exposure in active smokers while smoking using breath analysis technique, Chemosphere, 53, 207-216, 2003   DOI   ScienceOn
9 Leaderer, B. P., Cain, W. S., Isseroff, R. and Berglund, L.G. : Ventilation requirements - II. Particulate matter and carbon monoxide from cigarette smoking. Atmospheric Environment, 18(1), 99-106, 1984   DOI
10 Godish, T. : Indoor Environmental Quality, Lewis Publisher, pp.77-79, 2001
11 Godish, T. : Indoor Air Poluution Control, Lewis Publishers, 208-213, 1990
12 Wang, T. C. : A study of bioeffluents in a college classroom. ASHRAE Trans, 81, 32-44, 1975
13 NRC : Environmental Tobacco Smoke Measuring Exposures and Assessing Health Effects, National Academy Press, Washington DC, pp.337, 1986
14 Johannson, I. : Determination of organic compounds indoor with potential reference to air quality. Atmosheric Environment, 12, 1371-1377, 1978   DOI
15 Willeke, K., Ayer, H. E. and Blanchard, J. D.: New method for quantitative respirator fit testing with aerosols. American Industrial Hygiene Association Journal, 42, 121-125, 1981   DOI
16 환경부 : 다중이용시설 등에 대한 실내공기질관리법, 실내공기질관리 업무편람, 2004
17 김윤신 : 실내환경과학, 민음사. 서울, 39-41, 1994
18 Spengler, J. D. : Buildings operations and ETS Exposure. Environmental Health Perspectives, 107(S2), 313-317, 1999   DOI
19 문경환, 변상훈, 최달웅, 이은일, 오은하, 김영환 : 실내 공기 중 일부 알데히드류에 대한 위해도 평가-일부 주택 및 아토피 환자 주택을 대상으로. 한국환경보건학회지, 32(1), 19-26, 2006   과학기술학회마을
20 Ott, W. R. : Mathematical models for predicting inddor air quality from smoking activity. Environmental Health Perspectives, 107(S2), 375-381, 1999   DOI
21 Repace, J. and Lowery, A. H. : Tobacco smoke, Ventilation and Indoor Air Quality, Science, Wash, 208, 464-472, 1980   DOI
22 USEPA : Respiratory Health Effects of Passive Smoking Lung Cancer and Other Disorder, EPA 600/690/006B, 1992
23 Lynn, D. A. : Air Pollutant -Threat and Response, Addeson-Wesley Publishing Co., 52-55, 1975
24 보건복지부 : 국민건강증진법 시행규칙[일부개정 2004.7.29 보건복지부령 제00290호], 2004
25 ACGIH : Industrial Ventilation -A Manual of Recommended Practice-, 25th ed., Cincinnati, OH, 2.6-2.7, 2004