• Title/Summary/Keyword: indoor dust

Search Result 239, Processing Time 0.026 seconds

A Study on Evaluation of IAQ in Dwelling House (주거건축의 IAQ에 관한 연구)

  • 박미진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.108-112
    • /
    • 1997
  • Recently, the use of Dwelling House has been expanded due to the rapid urbainzation and congestion of population in City. Indoor Air Quality in apartment houses was investigated by measuring pollutants such as $CO_2$ gas, dust concentration. In this study, the mesurements of indoor air environment were performed in Dwelling house in Seoul area to investigate indoor air environment and the relation of air contaminative and the response level. Indoor air contamination and living environment of the occupants have been compared & analyzed with practical investigation of IAQ in Seoul, Korea and Tokyo, Japan.

  • PDF

Comparison of Area vs Personal Total Dust Concentrations Measured by 37mm Closed-face Cassette and IPM Sampler (목재분진 농도 측정에 대한 37 mm closed-face 카세트법과 IPM 측정법 비교)

  • Lee, Dong-won;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 1996
  • This study was performed to estimate total dust concentrations and particle size distribution of wood dust in the furniture and sawmill industries. To compare total wood dust concentrations, two samplers recommended by the American Conference of Governmental Industrial Hygienists and by the National Institute for Occupational Safety and Health were used. Concentration data were analyzed by paired-t tests using the SAS program and two parameters of the particle size distributions were determined by histogram. The results were as follows: 1. Particle size distributions showed a unimodal pattern in cutting and a bimodal in sanding operations. Mass median aerodynamic diameters(MMAD) were $17.35{\mu}m$ in cutting, and $1.39{\mu}m$ for small mode and $18.89{\mu}m$ for large mode in sanding operations. The proportions of particle size larger than $9.8{\mu}m$ estimated by the impactor were 61.16 % in cutting and 62.33 % in sanding operations, respectively. 2. The average personal total dust concentrations measured by IPM sampler were $17.12mg/m^3$ (GSD=1.45) from indoor samples, $2.97mg/m^3$(GSD=1.90) from outdoor samples in cutting, and $8.01mg/m^3$(GSD=1.58) from sanding operation. And those of by 37 mm closed-face cassette were $9.12mg/m^3$(GSD=1.46), $1.06mg/m^3$(GSD=1.99) from cutting, and $3.32mg/m^3$(GSD=2.16) from sanding operations. 3. The average area total dust concentrations measured by IPM sampler were $1.88mg/m^3$(GSD=2.04) from indoor cutting, $4.76mg/m^3$(GSD=2.83) from indoor sanding operations. And those of by 37mm closed-face cassette were $0.49mg/m^3$(GSD=2.34) from cutting, and $1.32mg/m^3$(GSD=3.03) from sanding operations. 4. The ratio of personal total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 35.7 %, 53.3 % from cutting, and 41.4 % from sanding operations. 5. The ratio of area total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 26.1 % from cutting, and 27.7 % from sanding operations. 6. A statistically significant difference of total dust concentrations between the 37 mm closed-face cassette and the IPM sampler was found.

  • PDF

Contamination Characteristics of Heavy Metals in Indoor, Outdoor and Playground of Schools in the Gochang-Gun, Chonbuk Province of South Korea (전북 고창지역 학교 실내외 환경의 중금속 오염 특성)

  • Kim, Yong-Hwan;Chung, Duk-Ho;Cho, Kyu-Seong
    • Journal of the Korean earth science society
    • /
    • v.27 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Dust samples were collected from 10 middle and high schools in the Gochang-Gun, Korea. Heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cu, Pb and Zn in indoor's dusts were highly concentrated. Also concentrations of Cu, Ni, Pb and Zn in outdoor's dusts were highly concentrated. Concentrations of Cd, Cu and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools and high schools located in Jeonju-city, Korea. Compared with concentrations of heavy metals in soils and dusts in Korea, the environment of indoor and outdoor of classroom is highly concentrated except for Cu, Zn. The concentrations of playground is less than that of residential dust and main road dust and playground in Jeonju-city. Playground dusts in 1 school exhibited the enhanced heavy metal pollution with a pollution index (Kloke, 1979) greater than 1.0, but indoor and outdoor dusts in 7 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) yester than 1.0.

Size distributions of suspended fine particles during cleaning in an office (사무실의 실내 청소 과정에서 부유하는 미세먼지의 크기분포)

  • Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.25-33
    • /
    • 2018
  • In this study, the concentration of fine indoor dust and the size distribution of fine indoor dust were analyzed by measuring the dust generated during the cleaning process of an indoor office. We measured $PM_{10}$, $PM_{2.5}$, and $PM_{1.0}$ and analyzed the size distributions of dust larger than $0.3{\mu}m$ in diameter during cleaning. The results showed that the concentration of $PM_{10}$ increased rapidly during cleaning, however $PM_{1.0}$ did not increase. Before cleaning with a broom, the fine dust concentration was about $50{\mu}g/m^3$, but increased to about $400{\mu}g/m^3$ as cleaning progressed. In the case of indoor cleaning with a vacuum cleaner, the concentration of $PM_{10}$ increased during the cleaning process and the increase of $PM_{2.5}$ was relatively small. $PM_{1.0}$ did not increase as in the case of cleaning the broom.

Exposure Assessment and Asbestosis Pulmonum among Inhabitants near Abandoned Asbestos Mines Using Deposited Dust (폐석면광산 주변 지역의 주택 침적먼지의 석면 검출과 석면폐증의 관련성)

  • Ahn, Hoki;Yang, Wonho;Hwangbo, Young;Lee, Yong Jin
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.369-379
    • /
    • 2015
  • Objectives: The lack of reliable information on environmental pollution and health impacts related to asbestos contamination from abandoned mines has drawn attention to the need for a community health study. This study was performed to evaluate asbestos-related health symptoms among residents near abandoned asbestos mines located in the Chungcheong Provinces. In addition, exposure assessment for asbestos is needed although the exposure to asbestos was in the past. Methods: Past exposure to asbestos among inhabitants near abandoned asbestos mines was estimated by using surface sampling of deposited dust in indoor and outdoor residences. A total of 54 participants were divided into two groups with (34 cases) and without (20 controls) diseases related to asbestos. Surface sampling of deposited dust was carried out in indoor and outdoor residences by collecting 105 samples. Deposited dust for sampling was analyzed by polarization microscope (PLM) and scanning electron microscope?energy dispersive x-ray spectrometer (SEM-EDX) to detect asbestos. Subsequently, the elements of the deposited dust with asbestos were analyzed by SEM-EDX to assess the contribution of sources such as abandoned mines, slate and soil. Results: Among the 105 samples, asbestos was detected by PLM in 29 (27.6%) sampling points, and detected by SEM in 56 (48.6%) sampling points. Asbestos in indoor residences was detected by PLM in four sampling points, and by SEM in 12 sampling points. Asbestos detection in indoor residences may be due to ventilation between indoors and outdoors, and indicates long-term exposure. The asbestos detection rate for outdoor residences in the case group was higher than that in the control group. This can be explained as the case group having had higher exposure to asbestos, and there has been continuous exposure to asbestos in the control group as well as the case group. Conclusion: Past residential asbestos exposure may be associated with asbestosis among local residents near abandoned asbestos mines. Odds ratios were calculated for asbestos detection in outdoor residence by logistic regression analysis. Odds ratio between asbestos detection and asbestosis pulmonum was 3.36 (95% CI 0.90-12.53) (p=0.072), adjusting for age, sex, smoking status and work history with multi-variable logistic regression by PLM analysis method.

Effects of Housing Systems on Behaviour, Performance and Welfare of Fast-growing Broilers

  • Zhao, Zi-Guang;Li, Jian-Hong;Li, Xiang;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.140-146
    • /
    • 2014
  • This experiment aimed to evaluate the effects of different housing systems on behavioral activities, welfare and meat quality of fast-growing broilers. Two hundred broilers were allocated into two housing systems: indoor housing vs indoor with outdoor access. Their general behavior (feeding, drinking, fighting, standing, lying, walking, investigating, dust-bathing and preening) was observed, and tonic immobility, fluctuating asymmetry of legs and wings were measured, and meat quality was analyzed. The results showed that the indoor-housed broilers with outdoor access had significant higher standing, walking, investigating, dust-bathing and preening than those indoor only. However, farming system was not found to significantly affect their feeding, drinking and fighting activities (p>0.05). The value of FA of tibia length of the broilers with outdoor access was significantly lower than that of the indoor-housed birds ($1.57{\pm}1.30$ vs $2.76{\pm}1.40$, p<0.05), while no difference was found for the value of FA in tibia diameter and wing length (p>0.05). TI of the broilers with outdoor access was 165.5 that was significantly higher than that (147.2) of the indoor birds (p<0.05). However, death rate in the outdoor run groups was significantly higher than that of the indoor ones ($2.0{\pm}0.81$ vs $4.0{\pm}0.82$, p<0.05). Meat quality was not affected by the two farming systems. It can be concluded that the results of this study may suggest that the indoor housing with outdoor access provides enriched environment for broilers and facilitates the expression of natural behaviors of the broilers but resulted in poorer performance and higher death rate.

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

Design and Development of Remote Monitoring System for Confirmation of Indoor Environment (실내 환경 확인을 위한 원격 모니터링 시스템의 설계 및 개발)

  • Lee, Keonha;Kim, Suyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.5-8
    • /
    • 2019
  • Recently, we have been demanding the comfort of the indoor environment due to environmental problems such as fine dust and yellow dust. In addition it is pursuing the most pleasant indoor environment for humans. In this study, we designed and implemented monitoring systems and mobile applications to enable information such as room temperature and humidity. Open source software and open source hardware are required to design and implement the systems proposed in this study. In this study, the systems implemented used a bluetooth module, a light sensor, and a temperature and humidity sensor. In the future, we expect to be a basic study of systems that can operate dehumidifiers, warm-air fans, fans and humidifiers using motors and optimize indoor environment.

  • PDF

Haptic AR Sports Technologies for Indoor Virtual Matches (실내 가상 경기를 위한 햅틱 AR 스포츠 기술)

  • Kim, J.S.;Jang, S.H.;Yang, S.I.;Yoon, M.S.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.4
    • /
    • pp.92-102
    • /
    • 2021
  • Outdoor sports activities have been restricted by serious air pollution, such as fine dust and yellow dust, and abnormal meteorological change, such as heatwave and heavy snow. These environmental problems have rapidly increased the demand for indoor sports activities. Virtual sports, such as virtual golf, virtual baseball, virtual soccer, etc., allow playing various sports games without going outdoors. Indoor sports industries and markets have seen rapid growth since the advent of virtual sports. Most virtual sports platforms use screen-based virtual reality techniques, which are why they are called screen sports. However, these platforms cannot support various sports games, especially virtual match games, such as squash, boxing, and so on, because existing screen-based virtual reality sports techniques use real balls and players. This article presents screen-based haptic-augmented reality technologies for a new virtual sports platform. The new platform does not use real balls and players to solve the limitations of previous platforms. Here, various technologies, including human motion tracking, human action recognition, haptic feedback, screen-based augmented-reality systems, and augmented-reality sports content, are unified for the new virtual sports platform. From these haptic-augmented reality technologies, the proposed platform supports sports games, including indoor virtual matches, that existing virtual sports platforms cannot support.

An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance (30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구)

  • Noh, Ji-Hee;Park, Sang-Hyun;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.