• 제목/요약/키워드: indoor comfort

검색결과 354건 처리시간 0.029초

교실 천장형 Unit의 위치에 따른 온열환경 평가 연구 (A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom)

  • 조성우;최정민;손영환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측 (Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD)

  • 손정은;유병호;방승기;이광호
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

활성탄 및 기능성 촉매제를 이용한 콘크리트의 포름알데히드 제거에 관한 실험적 연구 (Experimental Study on Formaldehyde Removal of Concrete by Using Activated Carbon and Functional Catalyst Materials)

  • 윤기원;이주헌;최명화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.729-732
    • /
    • 2008
  • 최근 실내공기질에 대한 관심이 집중되고 있는 가운데 이를 개선하고자 하는 노력이 다각도로 진행되고 있다. 본 연구는 기존의 친환경 마감재 적용 기술과 달리 콘크리트 자체에 활성탄과 흡착된 오염 공기를 분해할 수 있도록 기능성 촉매를 혼입함으로써 기본적인 물성과 포름알데히드 제거율을 시험하여 공기정화 효과를 분석하고자 하였다. 실험 결과 활성탄의 첨가량 증가에 따라 슬럼프는 감소하는 경향을 나타내었고, 압축강도는 큰 차이 없이 유사한 것으로 나타났다. 공기질 개선과 관련하여 포름알데히드 제거율을 시험한 결과 최대 80%까지 제거하는 것으로 나타났다.

  • PDF

비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교 (A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode)

  • 김용기;이태원;강성주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF

사무소건물의 가동식 수평차양에 대한 연구 (A Study on Design of Movable Horizontal Shading Device for Office Building)

  • 김미현;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.50-57
    • /
    • 2008
  • This study intends to evaluate the effect on indoor environment(annual thermal load, sunshine)by the application of the movable horizontal shading device on summer and winter season. For these purpose, we supposed the models which are composed of the several horizontal shading devices. Then we analyzed the simulation using the IES5.5.1 and Seoul weather data. The results of this study are as follows: 1) The proper length, angle of horizontal shading device is 2.1m, 28 degree, respectively. 2) The decreasing rate of the annual load of the Movable Horizontal Shading Model(MHSM) in comparison with the No Shading Model(NSM) & Conventional Horizontal Shading Model(CHSM) is 31.11%, 6.63% respectively. 3) The decrease of sunshine of the MHSM on summer season is effective the alleviation of visual displeasure. On the other hand, the increase of sunshine of the MHSM on winter season is effective the psychological comfort. Further study is to be required the sensitivity analysis on the various shading length for the realistic proper shading length.

사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구 (A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance)

  • 서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

풍향에 따른 건물군에서의 열환경 변화 (Change of thermal environment in buildings by wind direction)

  • 김상진
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.27-32
    • /
    • 2012
  • In recent years, the quality of the outdoor thermal environment has come to be regarded as important as that of the indoor thermal environment. Since the outdoor thermal environment is composed of many elements and is affected by many factors, it is not easy to evaluate the impact of each factor separately. Hence, a comprehensive assessment method is required. In order to evaluate the pedestrian level comfort of an outdoor climate, it is necessary to investigate not only wind velocity but also various physical elements, such as temperature, moisture, radiation, etc. Prediction of wind and thermal environment for a large scale buildings is one of the most important targets for research. Wind and thermal change in a city area is a very complicated phenomenon affected by many physical processes. The purpose of this study is to develop a design plan for wind environment at a large Buildings. In this study, we analyze outdoor wind environment and thermal environment on buildings using the CFD (Computational Fluid Dynamics) method. The arrangement of building models is an apartment in Jeonju. These prediction of wind and thermal environment for a large scale buildings is necessary in a plan before a building is built.

교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가 (Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom)

  • 권대혁;이재로;오주석;위승환;김수민
    • 한국가구학회지
    • /
    • 제28권3호
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

계시별 전기 요금제하의 에너지 절약을 위한 건물 냉방 제어 방법의 개발 (Development of a Novel Air-Conditioning Method for Energy Savings in Commercial Building Under Time of Use Electricity Pricing)

  • 노성준;전정표;김광호
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.164-170
    • /
    • 2013
  • The commercial buildings are consuming about 30% of total energy used in Korea. And a large amount of energy consumption in commercial buildings is consumed by HVAC(Heating, Ventilation, Air Conditioning) system. Therefore, if we can reduce the energy consumption in HVAC or air-conditioning system in commercial buildings, the overall energy consumption in Korea can be reduced. Currently, an electricity charge called Time of Use (TOU) is applied to typical commercial buildings. This paper proposes the novel energy management method where the temperature setting of air-conditioning system are adjusted to minimize the use of electrical energy while indoor comfort level is retained. The simulation test for a typical commercial building shows that the proposed method gives over 10% savings in electricity bills and electricity consumption compared to the conventional air-conditioning method.

강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교 (Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF