• 제목/요약/키워드: indoor and outdoor

검색결과 1,344건 처리시간 0.023초

실내외 공공공간의 디자인 연계성에 관한 복합문화공간의 사례분석 (A Study on the Design Connection of Indoor and Outdoor Public Space in the Case Analysis of Multiplex Cultural Space)

  • 안희선;남경숙
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.295-298
    • /
    • 2008
  • The value of space is changing with change of modern society value. In this change, there is consistent subject about 'public'. So, design studies of public space for indoor and outdoor space are being carried out. Also, the concept of total design for space is a essential element and substance plan about space design and marketing is accomplished based on the total design. Now days, multiplex cultural space which have the concept of public and total design is increasing interest. Therefore, a case of multiplex cultural space, a purpose of this paper is elements investigate which design elements in public space of indoor and outdoor how it have been connecting fundamental design elements.

  • PDF

Indoor and outdoor pullout tests for retrofit anchors in low strength concrete

  • Cavunt, Derya;Cavunt, Yavuz S.;Ilki, Alper
    • Computers and Concrete
    • /
    • 제18권5호
    • /
    • pp.951-968
    • /
    • 2016
  • In this study, pullout capacities of post-installed deformed bars anchored in low strength concrete using different bonding materials are investigated experimentally. The experimental study was conducted under outdoor and indoor conditions; on the beams of an actual reinforced concrete building and on concrete bases constructed at Istanbul Technical University (ITU). Ready-mixed cement based anchorage mortar with modified polymers (M1), ordinary cement with modified polymer admixture (M2), and epoxy based anchorage mortar with two components (E) were used as bonding material. Furthermore, test results are compared with the predictions of current analytical models. Findings of the study showed that properly designed cement based mortars can be efficiently used for anchoring deformed bars in low quality concrete. It is important to note that the cost of cement based mortar is much lower with respect to conventional epoxy based anchorage materials.

실내외 환경에서 센서노드의 성능 평가 (Performance Analysis of Wireless Sensor Nodes over Indoor and Outdoor Environments)

  • 적학초;문병현
    • 한국산업정보학회논문지
    • /
    • 제17권2호
    • /
    • pp.1-9
    • /
    • 2012
  • 오늘날 무선센서노드는 환경모니터링과 같은 다양한 응용분야에서 많이 사용된다. 본 논문에서는 실내환경에서 전파를 방해하는 장애물(콘크리트 내벽, 철문)과 2.4GHz의 무선랜(IEEE 802.11b/g)이 있는 환경에서 센서노드의 RSSI(Received Signal Strength Indication)와 PER(Packet Error Rate)을 측정하였다. 또한 다양한 실외 환경에서 센서노드의 RSSI와 PER을 측정하였다. 본 논문을 통해 분석되어진 데이터를 바탕으로 실내외 환경에서 데이터의 손실을 최소화할 수 있는 안정적인 무선센서네트워크의 구축에 필요한 가이드라인을 제시한다.

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향 (The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

Analysis of Interference between UWB and ITS

  • Park, Se-Ho;Kim, Eun-Cheol;Kim, Jin-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제9권4호
    • /
    • pp.202-210
    • /
    • 2009
  • In this paper, we have analyzed the effect of interference between ultra-wideband(UWB) and intelligent transport systems(ITS). The maximum possible UWB emission power and minimum possible distance between UWB devices and ITS are found. In order to analyze the interference, we employ the Monte-Carlo(MC) method. We consider six situations, which are indoor office line-of-sight(LOS), indoor office non-line-of-sight(NLOS), indoor residential LOS, indoor residential NLOS, outdoor rural LOS, and outdoor rural NLOS environments. From the simulation results, it is confirmed that coexistence between UWB and ITS devices can be realized in accordance with the emission mask of 19.3 dB for indoor application or 19.3 dB for an image system. And in the outdoors, coexistence between UWB and ITS devices can be realized if the emission mask is at least 1.6 dB for vehicles' radar systems.

SDS-TWR based Location Compensation Mechanism for Localization System in Wireless Sensor Network

  • Lee, Dong-Myung
    • 공학교육연구
    • /
    • 제13권5호
    • /
    • pp.76-80
    • /
    • 2010
  • In this paper, the Location Compensation Mechanism using equivalent distance rate ($LCM_{edr}$) for localization system based on SDS-TWR (Symmetric Double-Sided Two-Way Ranging) in wireless sensor network is proposed. The performance of the mechanism is experimented in terms of two types of the localization tracking scenarios of indoor and outdoor environments in university campus. From the experimentations, the compensation ratio in the $LCM_{edr}$ is better than that in SDS-TWR about 90% in indoor/outdoor environments in scenario 1 but also is better than that of SDS-TWR about 91.7% in indoor environment and about 100% in outdoor environment in scenario 2 respectively.

  • PDF

비 포괄적인 금연정책을 시행한 호프집의 면적에 따른 실내 PM2.5 농도 (Indoor PM2.5 Concentrations in Different Sizes of Pubs with Non-comprehensive Smoke-free Regulation)

  • 김정훈;임채윤;이대엽;김혜진;곽수영;이나은;김상환;하권철;이기영
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.126-132
    • /
    • 2015
  • Objectives: The Korean government implemented a smoke-free regulation for pubs with a net indoor area of ${\geq}100m^2$ on January 1, 2014. The purpose of this study was to determine the indoor levels of concentrations of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) in implemented and non-implemented pubs in Seoul and Changwon. Methods: $PM_{2.5}$ concentrations in fifty-two $100-150m^2$ (implemented) and fifty-seven < $100m^2$ (non-implemented) pubs were measured. A real-time aerosol monitor was used to measure $PM_{2.5}$ concentrations. Field technicians recorded characteristics of the pubs including net indoor area, indoor volume and presence of smoking rooms and counted the number of burning cigarettes, patrons and vents. Results: Differences between indoor and outdoor $PM_{2.5}$ concentrations in $100-150m^2$ and < $100m^2$ pubs were not significantly different in each city. Smoking was observed in 33% of $100-150m^2$ pubs and 51% of < $100m^2$ pubs. Average differences between indoor and outdoor $PM_{2.5}$ concentrations in the $100-150m^2$ and < $100m^2$ pubs were $79.2{\mu}g/m^3$ and $155.6{\mu}g/m^3$, respectively. When smokers were not observed, differences between indoor and outdoor $PM_{2.5}$ concentrations ware $12.4{\mu}g/m^3$ in $100-150m^2$ pubs and $24.5{\mu}g/m^3$ in < $100m^2$ pubs. Conclusion: Although the regulation was implemented only in ${\geq}100m^2$ pubs, a higher difference between indoor and outdoor $PM_{2.5}$ concentrations was observed in implemented and non-implemented pubs with smokers. Strict implementation of the regulation in all pubs is needed for better indoor air quality.

다결정 실리콘 태양광 모듈의 옥외 성능 평가 (Outdoor Performance Evaluation of Multi-Crystalline Silicon Photovoltaic Module)

  • 이유리;김우경;정재학
    • Current Photovoltaic Research
    • /
    • 제7권3호
    • /
    • pp.71-75
    • /
    • 2019
  • Solar energy is one of the renewable energy sources. It can respond to expanding energy demand. A solar cell module is designed to have a durability that can be developed over a long period of 25 years to be installed outdoors and perform like a stable power supply. We need Standard Test Condition (STC)-based power output data before and after testing to measure the power output of existing modules. The modules are shown to reduce power output by comparing data before and after outdoor experiments regardless of whether they are indoor or outdoor. It is easy to compare the power output quantities through the module simulator in the indoor. However, it takes a lot of testing time and costs to compare the power output on outdoor in the case of a high number of modules and distance from the module simulator. It can save time and costs if we can check the power output using the data in outdoor. We have used the long-term outdoor test to find the elements out that corresponds to the reductions in power output quantities. We have conducted research that matched the actual and the tests.

윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구 (An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference)

  • 한동훈;김영식;정한식;정효민;최순호
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.