• 제목/요약/키워드: indoor and outdoor

검색결과 1,342건 처리시간 0.028초

온도, 습도 및 냉방부하 예측에 관한 연구 (A Study on the Estimation of Temperature, Humidity and Cooling Load)

  • 유성연;한승호;이제묘;한규현;노관종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구 (A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

Design parameter analysis for ATSC 1.0 single frequency networks based on receiver multipath handling performance

  • Hernandez-Flores, Mario A.;Galeano-Torres, Rodrigo;Garcia-Castillo, Miguel A.;Landeros-Ayala, Salvador;Matias-Maruri, Jose M.
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.702-716
    • /
    • 2021
  • This work proposes suitable network configurations for single frequency networks (SFNs) with ATSC 1.0 based on network coverage calculations and the laboratory multipath handling performance of commercial receivers. SFNs are widely used for delivering terrestrial digital television services because of their efficient use of the spectrum. In Mexico the analogue television transmissions switch-off occurred on 31 December 2016. Thus it is expected the adopted ATSC 1.0 system will be in force for the next several years despite the recent standardization of the ATSC 3.0 system. As ATSC 1.0 uses 8-VSB modulation the multipath handling capability of receivers is critical for the design of SFNs. The presented network planning results help develop technical normativity for implementing SFNs in Mexico and other countries that use ATSC 1.0. SFNs with transmitter separation up to 130 km are fully covered for outdoor reception mainly due to the directivity of the receiving antenna. Moreover for indoor reception at least 70% of an SFN coverage area can be achieved with a transmitter separation of up to 60 km depending on the radiated power and the transmitter antenna height.

농촌 마을회관 이용자의 건강성 지향에 관한 연구 (A Study on the Healthy Orientation of Rural Community Center Users)

  • 김은자;유아현;조한솔;박미정;임창수
    • 한국농촌건축학회논문집
    • /
    • 제21권1호
    • /
    • pp.25-36
    • /
    • 2019
  • This study is a basic study for the planning of rural community center space, which introduced the concept of healthcare. As the rural community center is a place where the elderly in rural areas live mainly during the day, this place is very important place for the healthy life of the rural elderly. We conducted an interview survey for 207 users over 65. The survey was organized with three regions to consider the regional characteristics of the community center users and geographical characteristics. As a result of the analysis of planning elements, the main preferences for indoor and outdoor space elements are planning elements such as safety, air quality, light, and the thermal environment and safety handle, night lights, safety walkway. These preferences should be considered for the more healthy friendly rural community center.

EpiLoc: Deep Camera Localization Under Epipolar Constraint

  • Xu, Luoyuan;Guan, Tao;Luo, Yawei;Wang, Yuesong;Chen, Zhuo;Liu, WenKai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권6호
    • /
    • pp.2044-2059
    • /
    • 2022
  • Recent works have shown that the geometric constraint can be harnessed to boost the performance of CNN-based camera localization. However, the existing strategies are limited to imposing image-level constraint between pose pairs, which is weak and coarse-gained. In this paper, we introduce a pixel-level epipolar geometry constraint to vanilla localization framework without the ground-truth 3D information. Dubbed EpiLoc, our method establishes the geometric relationship between pixels in different images by utilizing the epipolar geometry thus forcing the network to regress more accurate poses. We also propose a variant called EpiSingle to cope with non-sequential training images, which can construct the epipolar geometry constraint based on a single image in a self-supervised manner. Extensive experiments on the public indoor 7Scenes and outdoor RobotCar datasets show that the proposed pixel-level constraint is valuable, and helps our EpiLoc achieve state-of-the-art results in the end-to-end camera localization task.

대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구 (Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology)

  • 박덕신;권순박;조영민;장성기;전재식;박은영
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

경주석빙고의 정량적 훼손도 평가와 미기후환경 분석 (Quantitative Deterioration Assessment and Microclimatic Analysis of the Gyeongju Seokbinggo (Ice-storing Stone Warehouse), Korea)

  • 김지영;이찬희;이명성
    • 보존과학회지
    • /
    • 제25권1호
    • /
    • pp.25-38
    • /
    • 2009
  • 경주석빙고(보물 제66호)는 조선시대 얼음 저장고로서 주구성암석은 유백색 색조를 띠고 정동이 발달한 중립질의 알칼리화강암이다. 훼손도 평가 결과, 균열(12.5%), 이격(6.7%), 탈락(25.1%), 박락(20.9%), 백화현상(6.5%), 갈색 변색(9.8%), 암흑색 변색(2.0%) 및 생물에 의한 변색(26.5%) 등이 높은 것으로 확인되었다. 전체적인 물리적 훼손율은 43.7%로 홍예틀 1번과 2번에서, 변색에 의한 훼손율은 68.7%로 북벽에서 가장 높아 석빙고의 훼손 상태가 매우 심각한 것으로 평가되었다. 석빙고 내부는 겨울철을 제외하고 연중 90% 이상의 높은 상대습도를 유지하였으며, 내부 미기후는 외부 기후 변화에 의존하나 외부보다 변동이 현저히 적은 일정한 환경을 유지하고 있었다. 상대습도는 봄과 여름에 98~100%에 최빈값을 보였다. 훼손의 근본적인 요인은 강수와 지하수의 유입 및 결로수에 의한 높은 상대습도와 장기적인 수분 유지시간이다. 이 수분은 생물에 의한 변색, 부재의 재질약화, 구조체의 거동, 백화현상 등을 야기하였다. 한편 입구 전면의 사질토양으로 인한 분진과 부유 입자가 내부의 갈색 및 암흑색 변색을 가중시켰다.

  • PDF

스마트폰을 이용한 사진 기반 가상 현실 노출 치료 시스템 개발 및 시험적 적용 (Development of a Smartphone based Photo-realistic Virtual Reality Exposure Therapy System)

  • 박종현;박진영;김광욱
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제22권3호
    • /
    • pp.75-87
    • /
    • 2016
  • 사진 기반의 가상 현실 노출 치료 요법(Virtual Reality Exposure Therapy)은 다양한 정신 질환의 평가 및 치료 연구에 사용되어 왔다. 그러나 최근에 보급되기 시작한 스마트폰 기반의 헤드 마운트 디스플레이(Head-mounted display, HMD)를 활용한 가상 현실 노출 치료 연구는 거의 없었다. 본 연구에서는 스마트폰 기반의 가상현실 기기를 활용하여 환경 촬영부터 노출까지 누구나 쉽게 사용할 수 있는 실제 사진 기반의 가상 현실(Photo-realistic VR) 노출 시스템을 제안하고, 32명의 정상군을 대상으로 시험적으로 적용하고자 한다. 본 연구 결과에 따르면 개발된 스마트폰 기반의 시스템은 실내/실외, 친숙한/친숙하지 않은 환경들에서 피험자의 감정 변화를 이끌어내었다. 이에 대한 의의와 모바일 기반의 가상현실 노출 치료 시스템의 장점에 대하여 본 연구에서 논의하였다.

선박용 리미트 스위치 박스의 설계에 관한 연구 (A Study on the Design of the Limit Switch Box for a Ship)

  • 이승희;고석조;이민철;김해수;김창동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.899-903
    • /
    • 2004
  • A limit switch box is used for a indicator of a valve actuator. This device indicates an opening and closing of a valve or throttle in a valve actuator. In ship, equipments are required safe and robust because of a rough environment and a specific condition during a voyage. However, the limit switch box is used in an indoor environment generally. Thus, a new limit switch box must be developed which can be used at an outdoor environment. This study designed the limit switch box. The housing of the limit switch box was made by an aluminium die cast method with surface painting after anodizing or chromate coating. In order to evaluate the endurance of the housing, the endurance tests against salt water have been conducted. Experiment results showed that the proposed device provides a reliable performance against salt water.

  • PDF

정렬비행을 위한 적응 스칼라 필터의 성능 분석 (Performance Analysis of Scalar Adaptive Filter for Formation Flying)

  • 임준규;박찬국;이달호
    • 한국항공우주학회지
    • /
    • 제36권5호
    • /
    • pp.455-461
    • /
    • 2008
  • 본 논문에서는 스칼라 필터와 적응 스칼라 필터의 성능을 비교 분석하였다. 외부 실험 과 비슷한 실험 환경을 만들기 위해서 GPS를 대신할 수 있는 초음파 의사위성을 사용하였다. 적응 스칼라 필터는 스칼라 필터와는 달리 적응기법을 사용하여 연속적으로 속도오차 공분산과 측정잡음 공분산을 추정한다. 실험결과, 적응 기법을 사용하여 위의 두 파라미터를 연속적으로 추정하는 적응 스칼라 필터의 위치 추정 성능이 스칼라 필터보다 더 좋다는 것을 확인하였다.