A Study on the Perception Level and Proper Management of Indoor Air Quality Recognition in Elderly Care Hospital Workers

  • Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.171-178
    • /
    • 2019
  • In this paper, we proposed a plan for a indoor air quality management in elderly care hospital by measuring the indoor air quality level of elderly care hospital and conducting a survey the workers' awareness of indoor air quality. The measurement items were Temperature, Humidity, CO2, CO, PM10, VOC and were taken on April 26, 2019. The survey found that the lower the satisfaction level with indoor air quality, the better outdoor air quality and odor items were analyzed to be the lowest among the indoor environmental factors. When the satisfaction level of indoor air quality is high, the satisfaction level of indoor environment factor is high. The result of the multiple response analysis was "lack of ventilation" and the regression analysis was the lower the "relevance of indoor air quality" category. To provide the best indoor air quality environment for elderly care hospital workers the installation of additional ventilation equipment to remove odors, the increase in the number of natural ventilation and the designation of regular ventilation personnel will be necessary. By establishing such a plan, it is possible to provide indoor air quality environment to provide the best services for elderly care hospital workers.

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

The Development and Application of Textbook Relevant to School Indoor Air Quality - Focused on 5th, 6th Grade Students - (학교 실내 공기질 관련 초등환경교육 교재 개발 - 5, 6학년을 중심으로 -)

  • Lee, Mi-Ae;Moon, Yun-Seob;Hwang, Eun-Ja
    • Hwankyungkyoyuk
    • /
    • v.21 no.4
    • /
    • pp.40-66
    • /
    • 2008
  • The purpose of this study is to develop and applicate textbook relevant to school indoor air quality. To achieve the purpose, concrete study process are as follows. First, the survey research to teachers, supervisors, and students is conducted to grasp cognition of subjects in elementary school and management situation about school indoor air quality. Second, contents relevant to indoor air quality on textbooks in the 7th elementary curriculum and subsidiary textbooks is analysed through reference study. Third, environmental textbook relevant to school indoor air quality for 5th and 6th grade in elementary school is developed, applicated, and inspected its effect on the basis of implications from results of survey and reference study. The results of this study are as follows. First, the result of survey concerning school indoor air quality showed that three groups had negative attitude for its management even though they thought that it affected human's health and study by and large. Student group thought that each of students itself was a little influence to school indoor air pollution though all of three groups answered that' activities of students' was its main source. Efforts of students to improve school indoor air quality was not much, and its main reason was that they didn't know about school indoor air pollution well. Second, result of analysis into textbooks on the 7th elementary curriculum and subsidiary textbooks, contents concerning indoor air on the 7th elementary curriculum textbooks was little or nothing. And it trended to be included to subsidiary textbooks. However, education textbooks about indoor air for elementary students was insufficient still. Third, environmental textbook relevant to school indoor air quality for 5th and 6th grade in elementary school was developed. It was constructed for themes - importance, sources, effects, and management of school indoor air quality. After its application to the 6th grade students in elementary school, it was meaningful in the level of p<.05 that the result of knowledge and awareness in the pre-post test within experiment group. However, all of the results in comparison group didn't represent statistically meaningful difference. In conclusion, environmental textbook developed by necessity of education about school indoor air quality will play a role as useful tool for the 5th, 6th grade students in elementary school to understand relation of quality of health and life and school indoor air quality, to have attitude to make an effort to manage it by develop right awareness about it.

  • PDF

A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility (교육시설물의 실내공기질 측정 및 개선방안에 관한 연구)

  • Kim, Sung-Kyum;Kim, Jae-On;Cho, Chang-Yeon;Kim, Jong-Rok;Son, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.4
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.

Variation of Indoor Air Quality in Museum (박물관 실내공기질 변동에 관한 연구)

  • 이정주;김신도;부문자
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

School Indoor Air Quality and Health Effects (학교 실내공기질 및 건강 영향)

  • Yang, Won-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.143-152
    • /
    • 2009
  • Indoor air quality at classrooms is of special concern since students are susceptible and indoor air problems can be so subtle that it does not always produce easily recognizable health effects. The main objectives of the study were to investigate the time-activity pattern of school students, to determine the sources of poor indoor air quality in schools, and to demonstrate how indoor air quality in schools causes adverse health effects such as headache, upper airway irritation, fatigue, and lethargy. Recent articles ranging from 1987-2009 related to school indoor air quality were systematically reviewed. Building-associated health effects can increase student absences from school and degrade the performance of children while in school. The reduced ventilation rate was associated with a decreased ability to concentrate along with increased adverse health symptoms. There was an association between residential proximity to busy roads and a variety of adverse respiratory health outcomes in children. Consequently, the current findings suggest the need for control strategy for school indoor air pollutants with multidisciplinary approach methods because Korea has no other natural resources except manpower especially.

A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions (온도 및 습도 조건에 따른 침실 공기환경에 관한 연구)

  • Kim, Dong-Gyu;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

The Measurement of the Indoor Air Quality in KTX Train (KTX 객실내 공기청정도 측정)

  • So, Jin-Sub;Lee, Sung-Uk;Park, Duck-Shin;Yoo, Seong-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1210-1213
    • /
    • 2006
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The KTX HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is planning to enforce$\square\square$Indoor Air Quality Management law in Public Facilities$\square\square$in year 2008. Hereupon, the train and the subway are included. In this research air quality in the KTX Train compartment has measured. As a result, The average amounts of PM10(particulate matters), $CO_2$(carbon dioxide)measured $20{\mu}g/m^3$, 1,097ppm in KTX respectively. There are compare to regulation the value is 10% for PM10 and 43% for $CO_2$. Thus, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

  • PDF