The Measurement of the Indoor Air Quality in KTX Train

KTX 객실내 공기청정도 측정

  • 소진섭 (한국철도공사 철도연구개발센터, 기술연구팀) ;
  • 이성욱 (한국철도공사 철도연구개발센터, 기술연구팀) ;
  • 박덕신 (한국철도기술연구원, 환경.화재연구팀) ;
  • 유성연 (충남대학교 대학원 기계설계공학과)
  • Published : 2006.11.09

Abstract

Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The KTX HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is planning to enforce$\square\square$Indoor Air Quality Management law in Public Facilities$\square\square$in year 2008. Hereupon, the train and the subway are included. In this research air quality in the KTX Train compartment has measured. As a result, The average amounts of PM10(particulate matters), $CO_2$(carbon dioxide)measured $20{\mu}g/m^3$, 1,097ppm in KTX respectively. There are compare to regulation the value is 10% for PM10 and 43% for $CO_2$. Thus, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

Keywords