• 제목/요약/키워드: indoor air quality

검색결과 1,009건 처리시간 0.03초

환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토 (The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment)

  • 최석용;김상희;이정재
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가 (Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu)

  • 박현식;김현태;홍원화
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

환경보건학적 관점에서 본 메르스 사태의 문제점 - 병원 실내공기질 관리를 중심으로 - (Problems of the Middle East Respiratory Syndrome Outbreak from the Perspective of Environmental Health - Focusing on Control of Indoor Air Quality in Hospitals -)

  • 허다안;이정현;허은혜;문경환
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.216-221
    • /
    • 2015
  • Since Patient Zero of MERS was diagnosed in May 20, 2015, cases of MERS continued to grow. The current situation, which people have been confirmed to be infected, suggested that contaminated indoor air could be the potential cause of hospital-acquired infections. It is important to address the indoor air quality in hospitals because pathogens can spread through air. While the heating, ventilating and air conditioning(HVAC) system is useful managing indoor air quality in hospitals, it can transmit the pathogens if operated improperly. Therefore, it is necessary to remove contaminants in hospitals and operate the HVAC system according to the guidelines, in order to maintain clean indoor air.

빌딩내에서 무선센서네트워크를 이용하는 쿼리기반의 실내공기 질 모니터링시스템 (Query-based Indoor air Quality monitoring system Using wireless sensor network inside the Building)

  • 이승철;정완영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.627-628
    • /
    • 2008
  • This paper proposes an indoor air Quality monitoring system for measuring various indoor air qualities using IEEE 802.15.4 based wireless sensor network. For indoor air quality monitoring, sensor nodes include carbon monoxide sensor and dust sensor were used. The wireless network by deployed sensor nodes has limited energy, computing, communication capabilities and memory sizes. In this paper, the query process in indoor air quality monitoring was designed to improve the limited sensor node resources such as battery consumption and networking.

  • PDF

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해 (Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning)

  • 조완근;권기동;최상준;송동익
    • 한국환경과학회지
    • /
    • 제13권9호
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

창원지역 신축학교의 실내공기질 현장평가 연구 (A Study on the Field Evaluation about the Indoor Air Quality of Schools Newly Built in Changwon)

  • 유종훈;강은혜;손영환;하석용;최정민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1244-1249
    • /
    • 2006
  • Because students are spending more time in their classroom for learning and study, indoor air quality problems in school classrooms are very important. when the classroom is built for the first time, namely newly built school, the selection of inside finishing material is directly connected with indoor air quality problems especially with HCHO and TVOC. But until now, there is no plenty of study about this. Moreover, there are some concerns about the desks and chairs which are used in classroom will affect the air quality. but almost no study is being made at all Therefore, this study focuses on the field survey and analysis of classroom indoor air quality in newly built schools in Changwon. In this study filed surveys and analysis are conducted as follows. 1) The effect of the material difference in general classroom. 2) The effect of the material and loading ratio difference in special classroom. 3) The effect of the desks and chairs in general classroom.

  • PDF

사무실 실내공기중 휘발성유기화합물의 기준설정에 관한 연구 (A Study on the Standards of Volatile Organic Compounds in Indoor Air of Office)

  • 김윤신;이철민;노영만;이소담;손종렬;김석원
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.413-427
    • /
    • 2006
  • It is necessary to study and develop guidelines for providing comfort and health indoor air quality for office workers since air-tight envelope system of current office building may cause poor indoor air quality. The purpose of this study is to propose guideline for volatile organic compounds in office base on the field study, human health risk assessment and cost-benefit analysis. The field study was conducted to survey the concentrations of volatile organic compounds in indoor air of 69 offices from June to September, 2005 in Seoul and Gyeonggi-do. The rate of excess to guideline of volatile organic compounds in indoor air of new apartment on the Ministry of Environment in Korea(MOE) was surveyed 37.6% for benzene, 6.8% for toluene, and 1.5% for ethylbenzene. As the result of human health risk assessment, mean cancer risk did not exceed 10-6 which is guideline of US.EPA. Also, total hazard index did not exceed 1 which is guideline of US.EPA. Through the cost-benefit analysis of angle on the social-economics to verify the necessary to establish the standards of volatile organic compounds for improvement and development of indoor air quality in office, the present value of benefit was higher than the present value of cost. With the above considerations in mind, it is suggested that the field study for indoor air quality in offices should be expanded and human health risk assessment and cost-benefit analysis be performed th offer scientific data for decision-making of policy for improvement and management of indoor air quality in office.

A Review of Some Representative Techniques for Controlling the Indoor Volatile Organic Compounds

  • Kabir, Ehsanul;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권3호
    • /
    • pp.137-146
    • /
    • 2012
  • Poor indoor air quality is now worldwide concern due to its adverse impacts on our health and environment. Moreover, these impacts carry a significant burden to the economy. Various technical approaches (e.g., biological, activated carbon fiber (ACF), photocatlytic oxidation (PCO), etc.) have gained popularity in controlling indoor volatile organic compounds (VOCs). This is because removing indoor VOC sources or increasing ventilation rates is often not feasible or economical. This review provides an overview of the various air purification technologies used widely to improve indoor air quality. Although most of these technologies are very useful to remove indoor VOCs, there is no single fully satisfactory method due to their diversity and presence at the low concentration. To achieve technical innovations and the development of specific testing protocols, one should possess a better knowledge on the mechanisms of substrate uptake at VOC concentrations.

활성 알루미나 겔을 혼입한 고로슬래그 경화체의 실내오염물질 흡착 특성 (Adsorption Properties of Indoor Air Pollutants in Blast Furnace Slag Matrix with Active Alumina Gel)

  • 박채울;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2019
  • The indoor air quality of modern people who work indoors more than 80 percent a day has also become a very important factor in their lives. But most indoor air quality is highly polluted due to energy conservation and lack of ventilation. This can lead to pneumonia, asthma and even lung cancer, which can be fatal to children, the elderly and the elderly. Indoor pollutants are caused by boards, wallpaper, paint, etc. used in interior By producing indoor finishing materials using active alumina gel, which is used as dehumidifier, indoor pollutants will be reduced and the possibility of developing respiratory diseases and lung cancer will be reduced.

  • PDF