• 제목/요약/키워드: indoor air quality(IAQ)

검색결과 186건 처리시간 0.022초

건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구 (A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities)

  • 임태섭;강승모
    • 한국실내디자인학회논문집
    • /
    • 제20권4호
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.

공공위락 시설의 실내 공기환경에 관한 연구 (A Study on the Indoor Air Quality of Public Entertainment Facilities.)

  • 정재국
    • 한국주거학회논문집
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1998
  • This study aims to suggest ventilation design data for Public Entertainment Facilities in relation to Indoor Air Quality. The concentration of indoor air pollution such as CO, CO2, RH, Radon, HCHO, TSP was investigate, and the reguired ventilation rate of Public Rooms was calculated. As resuits of this study, the following conclusion could be obtained. Field measurement of P.E.F reveals that the concentration of CO2 was mist polluted and higher than IAQ standard, while that of other pollutats did not exceed the standard. In underground the concentration of CO2 increased 1130ppm(2 persons) 2170ppm(4 persons) 1970ppm(6 persons). The CO2 pollution was serions problem in underground more than second floor, in only exhaust ventilation system more than exhaust and supply system.

  • PDF

이동형 실내 공기질 측정 로봇 (Mobile Robot for Indoor Air Quality Monitoring)

  • 이소화;고동진;김나빈;박은서;전동렬;봉재환
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.537-542
    • /
    • 2022
  • 실내 공기질에 관한 관심과 중요성이 커지고 있으나 현재의 고정된 장비를 이용한 실내 공기질 측정 방법에는 한계가 있다. 본 논문에서는 이동 중 요철에 의한 진동을 최소화하여 탑재된 센서를 보호하기 위해 소형 다족형 로봇에 공기질 측정 장비를 탑재하여 이동형 공기질 측정 로봇을 개발하였다. 개발한 이동형 공기질 측정 로봇은 간단한 보행 메커니즘을 활용하여 DC 모터 두 개의 정회전과 역회전 조합만으로 로봇의 전진, 후진, 좌우 선회가 가능하다. 로봇의 보행이나 보행 궤적을 제어하기 위해 복잡한 연산이 필요치 않고 하나의 아두이노를 사용해 로봇의 보행 제어 및 다양한 공기질 측정 장비의 데이터 획득과 전송을 할 수 있었다. 로봇 전장부의 소모 전력이 낮아 비교적 저용량의 배터리를 탑재하여 배터리로 인한 무게를 줄일 수 있었다. 개발한 로봇은 몸통에 배터리와 모터를 포함하여 다양한 공기질 측정 장비를 탑재하고 1.4kg의 무게를 가지며, 보행 및 선회 속도는 3.75cm/sec와 14.13rad/sec로 측정되었다. 다리의 최대 수직 도달 높이는 33mm였으나, 요철은 최대 24mm 높이까지 극복할 수 있었다.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

신축 아파트의 실내 마감재 변경 및 시공단계별 휘발성유기화합물 발생 특성 (Characteristics of VOCs Emission According Interior Finish Materials and Working Phases of New Apartments)

  • 방승기;조우진;손장열
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.486-492
    • /
    • 2006
  • In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

건물 시공단계의 실내공기질 시뮬레이션 평가 연구 (A Study on the Simulation Evaluation of IAQ at the Process of Building Construction)

  • 최정민;조성우;박창섭;박민용;이경희
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.60-67
    • /
    • 2007
  • The purpose of this study is to evaluate indoor air quality at the stage of building construction. To check the IAQ at the stage of construction IAQX simulation program developed by EPA was used and the values of TVOC were analyzed with time-series. The Simulation conditions are as follows. 1) Ventilation rate, 2) Time schedule of works, 3) Material change. Through this simulation, the major factors which affect the IAQ were analyzed and the importance of empirical data about the time-series emission rate of concerned material could be confirmed.

동적 단열재의 열성능 측정에 관한 연구 (A Measurement Study of a Dynamic Insulator Thermal Performance)

  • 고선미;강은철;이의준
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.361-368
    • /
    • 2010
  • Due to the insulation and the air-tightness requirement in modern buildings have resulted NBS(New Building Syndrome) and SBS(Sick Building Syndrome) of IAQ problems. Therefore, energy efficient way of solving such IAQ issues are of major concern in these days and building industries. This paper introduces a method to improve thermal performance with a DI(Dynamic Insulation) concept. The characteristic of the dynamic insulation is that the lower U-value as the higher air velocity through the DI in a micro level. A thermal performance monitoring study has been conducted to show the energy impact of porous DI over the static insulation material. The results show that up to 45% could be improved in the case with DI compared to the conventional insulation.

병원건축의 친환경 성능 향상을 위한 국내외 친환경 건축물 평가항목의 비교 연구 (A Comparative Study of a Domestic and Foreign Green Architecture Evaluation Items for a Green Performance Enhancement of Hospital Architecture)

  • 이호성
    • 한국실내디자인학회논문집
    • /
    • 제18권1호
    • /
    • pp.99-107
    • /
    • 2009
  • In order to prepare future green hospital architecture authentication system, this study is a comparative year report to Korean, the United States, Japanese, British, Canadian and Australian green building authentication systems. Also, the United States and Australian Green hospital authentication systems were examined, and the authentication items of hospitals were compared with those of civil architecture. Though the examination and analysis, the portion of indoor environmental quality section commonly shows the average of 20.7 percent in all 6 countries. Especially, IAQ(Indoor Air Quality) among inside IEQ(Indoor Environment Quality) is overwhelmingly much treated in Korea, the U.S.A, Canada and Australia. In Japan, heat, light and sound are the important factors for authentication evaluation, while in the U.K light are more emphasized for the authentication. 'LEED for Healthcare' as a hospital evaluation authentication system subdivided currently most. The system includes the detailed and extensive evaluation items ranging from hospital management, traffic, emission, water resources utilization to integrated design and furnishing. These overseas systems should be carefully investigated, researched and analyzed for an appropriate improvement of domestic green hospital authentication system. Also the current evaluation method of IEQ section of Korean GBCC needs to be modified. That's why the method puts too much importance on IAQ in IEQ section.

전국 일부 학교 건축물 내의 실내 공기 및 인식도 조사 (The Assessment and Recognition on Indoor Air Quality at Schools in Korea)

  • 손종렬;윤승욱;김종혁;이용식;최한영;김영성;손부순;양원호;김민회
    • 환경위생공학
    • /
    • 제20권3호
    • /
    • pp.1-9
    • /
    • 2005
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the healthy effectsrelated to IAQ, specially in schools in Korea. Therefore, objectives of this study in this study were to measure and compare the perception of TAQ of selected air pollutants in Seoul from April to September 2004. Measurement place measured 2 schools of Seoul and local 9 schools (by Kyonggi Province, Chungchong-bukdo Chungchong-namdo, Chollado-bukdo, Cholla-namdo, Kyongsang-bukdo, Kyongsang-namdo, Kwangju, schoolin Pusan each 1 place). Temperature, humidity, illumination, carbon monoxide, carbon dioxide, TBC (total bacteria count), noise, PM10, TVOC(total volatile organic compounds), HCHO (formaldehyde) were measured simultaneously. Also, we Performed a questionnaire survey of 250 students and 50 teachers about their awareness for the importance of IAQ in their schools. Among this article, we handled noise, carbon monoxide, carbon dioxide, TBC, TVOC, HCHO, PM 10 in our conclusion. Major results were as follows ; Carbon monoxide (CO) was lower than indoor air standard of Korea. Carbon dioxide $(CO_2)$ appeared that 4 schools among our sample target school exceeded in normal standard. 4 schools were almost similar with normal standard. TBC appeared that 7 schools among 11 schools were higher than standard. Noise measured school's mean value passed exceeded standard. And school which passed over standard appeared to 7 schools among 11 schools. HCHO was exceeded 4 schools by standard that excess and certainly interrelation between school's establishment year and facilities of construction was detected. PM10 was exposed all schools by fitness in standard. TVOC appeared that 9 schools among 11 measurement school was exceeded health effect standard of Japan.

산후조리원 내 신생아실의 실내 환경 특성 - 목재가구류에 따른 실내공기질과 조명배치에 따른 조도 특성을 중심으로 - (Indoor Environment of Infant Units in Postnatal Care Center - Focus on Indoor Air Quality by Types of Wooden Furniture and Intensity of Illumination by Arrangement of Lights -)

  • 정소담;김태욱;장슬애;김석환;이상진
    • 한국가구학회지
    • /
    • 제24권1호
    • /
    • pp.33-41
    • /
    • 2013
  • As professional postnatal care systems have been rapidly supplied, there is sharp increase of postnatal care centers without legal regulations for a mother and a infant. For the quick recovery of mothers, newborn infants that have weaker immune systems are being managed in group in the postnatal care centers. Recently, the attention of the postnatal care centers has been growing because the problem of pneumonia which led to result in a casuality in a infant unit was happen. So, this research analyzed the indoor environment of infant unit through measuring formaldehyde, carbon dioxide, intensity of illumination. As a result of the data, infant units showed higher concentration of formaldehyde and carbon dioxide than Indoor Air Quality Control Law. Moreover, infant units was measured higher intensity of illumination than the range of optimum illumination for infants.

  • PDF