Abstract
The purpose of this study is to evaluate indoor air quality at the stage of building construction. To check the IAQ at the stage of construction IAQX simulation program developed by EPA was used and the values of TVOC were analyzed with time-series. The Simulation conditions are as follows. 1) Ventilation rate, 2) Time schedule of works, 3) Material change. Through this simulation, the major factors which affect the IAQ were analyzed and the importance of empirical data about the time-series emission rate of concerned material could be confirmed.
Keywords
Building; Construction; IAQ; Simulation; Time-series analysis; IAQX; TVOC; HCHO;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kim, S. H., No, S. T. and Kim, K. S., 2005, A study on natural airflow efficiency and indoor airflow characteristics with different types of openings in high-rise residential buildings, 2005 SAREK Summer Annual Conference, pp. 63-69
2 Hong, G. P., Kim, D. W., Joo, H. S., Kim, K. H., Kim, T. Y and Kim, B. S., 2005, Prediction of hospital indoor air quality based on building material grades using CFD method, 2005 SAREK Summer Annual Conference, pp. 91-96
3 Kang, D. H., Kim, J. H., Choi, D. H., Kim, S. S., Yeo, M. S. and Kim, K. W., 2005, A numerical analysis of VOCs emission affected by temperature variation in floor heating space, 2005 SAREK Summer Annual Conference, pp. 109-114
4 Kang, H.J., Yu, H. K., Park, J. C. and Rhee, E. K., 2005, An experimental study on the effect of IAQ improvement strategies for new apartment houses, 2005 SAREK Summer Annual Conference, pp. 795-800
5 Pang, S. K., Son, J. Y. and Ahn, B. W., 2005, Prediction of the concentration decay of volatile organic compounds under different air change rates and loading factor conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp. 505-513   과학기술학회마을
6 Lee, J. J., Lee, J. H. and Lee, S. M., 2005, IAQ field survey in an apartment housing equiped for heat recovery ventilation system with air cleaning function, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp.688-693   과학기술학회마을
7 Chun, C. Y., Kim, S. W., Sim, J. B. and Jo, W. J., 2005, A improvement of indoor air quality for apartment housing, 2005 SAREK Summer Annual Conference, pp. 1001-1005
8 Ministry of Land, Infrastructure and Transport in Japan, 2003, A manual for the prevention of the sick building according to the revised standard law of architecture, engineerin
9 Kim, S. D., 2005, The method of certificate in eco-friend materials, AIK, pp. 1-16
10 Kim, C. N:, Kim, D. S., Kim, T. Y, Lee, Y. G. and Leigh, S. B., 2005, An estimation of VOCs concentration in the apartment housing with sensible & latent heat recovery ventilator, 2005 SAREK Summer Annual Conference, pp. 70-75
11 Yu, H. K., Park, J. C. and Rhee, E. K., 2005, A study on a proper reduction process of indoor air pollutants in newly constructed multi-family houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.468-476   과학기술학회마을