• 제목/요약/키워드: indoor air pollutants

검색결과 308건 처리시간 0.031초

충남 지역 일부 학교의 PM10과 중금속 농도에 관한 연구 (The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area)

  • 손부순;송미라;김정덕;조태진;양원호;정태웅
    • 한국환경과학회지
    • /
    • 제17권9호
    • /
    • pp.1005-1013
    • /
    • 2008
  • In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.

일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가 (Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool)

  • 박해동;박현희;신정아;김태호
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

분말활성탄을 혼합한 도료의 도장횟수에 따른 흡착 특성 (Adsorption Properties of Paint Mixed with Powdered Activated Carbon According to the Number of Coatings)

  • 최병철;경인수;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2021
  • Due to COVID-19, the spread of non-face-to-face culture is increasing the time spent indoors. Accordingly, it is necessary to reduce indoor air pollutants. Also, among building materials, there are paints. As the number of coatings increases, the coating film becomes thick, and there is a risk of cracking and falling off. Therefore, this study is to examine the adsorption properties of indoor air pollutants according to the number of coatings of a paint mixed with powdered activated carbon. In the experimental plan, the addition ratio of powdered activated carbon was selected as 30%, and the number of coatings was selected as primcoating, second coat, and finishing coat, and the concentration of formaldehyde and volatile organic compounds were measured. As a result, as the number of coatings increased, the concentration of formaldehyde and volatile organic compounds tended to decrease. This is considered to be due to the fact that not only the physical adsorption acted by the internal pores of the powdered activated carbon, but also because a lot of powdered activated carbon was present on the painted surface as the coating film was formed. However, since it is judged that there is an error in the concentration due to the inflow of external air as the chamber cover is opened to put the test object in the adsorption test process, it is considered that the experimental method needs to be supplemented.

  • PDF

지하상가 실내외 및 지하철의 온도와 습도에 따른 Formaldehyde 거동(II) (Behavior of Formaldehyde Concentration by Temperature and Humidity of Indoor and Outdoor in Underground Shopping Center and Subway(II))

  • 권우택
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.67-75
    • /
    • 1994
  • Formaldehyde has been in widespread industrial use since World War II . Numerous sources of formaldehyde are present in the indoor environment. Additionally, the current trend toward tighter, more energy efficient buildings with lower ventilation rates has led to increase concentrations of this and other pollutants generated indoors. In this paper, the field survey was carried out once a month from January to MarctL 1994 to measure indoor and outdoor formaldehyde concentration in several underground locations in Seoul. The results could be summarized as follows : 1. At Yang- jae underground shopping center, the mean formaldehyde concentration was 77.8ppb for indoor and 68.4ppb for outdoor. At Ban- po underground shopping center, it was 175.8ppb for indoor and 127.3ppb for outdoor. At Jam- shil underground shop ping center, it was 135.2ppd for indoor and 34.6ppb for outdoor. Indoor the No.2 sub way line, it was 105.6ppb. The formaldehyde concentration using Berge equation was as follows : At Yang- jae underground shopping center, the mean formaldehyde concentration was 85.99ppb for indoor and 72.75ppb for outdoor At Ban- po underground shopping center, it was 254. 17ppb for indoor and 138.14ppb for outdoor. At Jam- shil underground shopping center, it was 249.13ppb for indoor and 36.87ppb for outdoor. Indoor the No.2 subway line, it was 131.73ppb. 3, The result of correlation analysis indicated that the relationship between temperature and formaldehyde concentration is very high( $\gamma $= 0.831 ∼ 0.974). 4. Also, the relationship between humidity and formaldehyde concentration is variant ($\gamma $ = 0.246 ∼0.999). 5. The mean formaldehyde concentration indoor and outdoor Ban- po underground shop ping center and indoor Jam- shil underground shopping center and indoor the No.2 sub way line exceed the American Society of Heating, Refrigeration, Air- conditioning Engineers( ASHRAE) stflndard of 100ppb(120 $\mu $g/m$^{3}$).

  • PDF

교육시설의 공기환경 실측에 관한 연구 (A Study on the Measurement of Indoor Air Pollutants in High School Building)

  • 김선정;김병수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1392-1397
    • /
    • 2008
  • This study is to measure the change of the $CO_2$ and floating dust concentration depending on the volume of the ventilation and the state of on/off the ventilation for the estimation of the air pollution in classroom. The results could be summarized as follows: the test cell was the two full scaled model and the one is set up with ventilation system another was not. the volume of classroom is 170.1m3 and the number of persons are 35. 1)when the ventilation system was not installed, The experimental results of the $CO_2$ concentration showed the average of 2,150ppm and the maximum of 2,740ppm in the classroom. This was the higher than 1,000ppm, the standard value of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development, 1000ppm. The $CO_2$ concentration was relatively increasing during school hours. 3)In case of the volume of ventilation of $800m^3$/h, the $CO_2$ concentration of classroom showed the average of 962 ppm and the maximum of 1,380 ppm. This was higher than 1,000ppm, the standard of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 4)The floating dust(PM10) was the maximum of 0.52 mg/$m^3$, the minimum of 0.25 mg/$m^3$, and the average of 0.32 mg/$m^3$ in case of the ventilation system off. Those were higher than the standard value 0.15 mg/$m^3$. In case of the ventilation system on, the floating dust(PM10) was the maximum of 0.174 mg/$m^3$ , the minimum of 0.048 mg/$m^3$, and the average of 0.078 mg/$m^3$. These were the lower than 0.15 mg/$m^3$, the standard of the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 5)The concentrations of $CO_2$ and PM10 were largely depending on the number of students and the ventilation system, The installation of the ventilation system is necessary for the amenity environment and the management of the indoor air quality.

  • PDF

대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구 (Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology)

  • 박덕신;권순박;조영민;장성기;전재식;박은영
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

복합적 기능의 식물 애플리케이션 디자인을 위한 사용자 조사 (A Study on User's Opinion for Designing of Multi-Functional Plant Applications)

  • 이하나;박한나;백진경
    • 한국과학예술포럼
    • /
    • 제37권4호
    • /
    • pp.297-308
    • /
    • 2019
  • 연일 최대치를 갱신하고 있는 미세먼지 수치로 인해 대한민국 정부는 공기 오염과 씨름하고 있으며, 환기의 어려움과 실내 방출 오염물질로 인한 실내공기 오염 문제 역시 심각하다. 이러한 실내의 공기 질 개선에 식물의 공기 정화 효과가 돋보이고 있다. 본 연구는 현대인의 생활 환경과 실내공기 오염의 위해성 및 식물의 개선 기능을 조사하고, 식물 애플리케이션 사용을 활성화하기 위하여 시작되었다. 본 연구의 목적은 국내외 식물 관련 애플리케이션의 주요기능과 디자인 현황을 파악하고, 현대인의 식물 애플리케이션 사용 실태를 분석하여 더욱 편리한 식물 관련 지식 습득을 돕는 것이다. 따라서 본 논문은 실내공기 오염이 건강에 미치는 영향과 식물 관련 애플리케이션에 대한 사용자 의식조사를 이행하였다. 이를 통해 새로운 복합적 기능의 식물 애플리케이션 디자인을 제안하는 데 근거를 마련하고자 시도하였다. 연구 결과 및 내용은 다음과 같다. 첫째, 이론적 고찰 결과 실내공기 오염은 실내 생활의 비중이 높은 현대인에게 더욱 위험하며 건강에 악영향을 끼친다. 이와 같은 문제 해결을 위하여 실내공간에 식물을 두는 것만으로도 공기 정화 및 스트레스 감소에 크게 효과를 볼 수 있었다. 둘째, 선행 연구 분석 결과 실내공기 오염의 위해성과 건강에 미치는 영향, 공기정화 식물의 실내 공기개선 사례와 관련된 연구 사례를 찾아볼 수 있었으며, 애플리케이션 개발 및 개선을 통한 사용자의 행동 개선 사례를 파악할 수 있었다. 셋째, 국내외 식물 애플리케이션 현황 조사 결과 현재 설치 수가 높은 애플리케이션의 주요 기능은 식물식별, 물 주기 알림, 식물 기초 정보 제공 등이 있었으며, 카메라를 통한 식물 식별 애플리케이션이 다수였다. 넷째, 설문조사 결과 대부분의 응답자가 식물을 키우고 있거나, 키운 경험이 있었다. 식물 애플리케이션을 사용한 경험이 거의 없는 사람 역시 향후 식물 관련 애플리케이션 사용에 긍정적인 의견을 밝혔다. 또한, 공기 오염 등의 사회 문제로 인하여 식물을 활용한 공기 정화, 기능성 식물 등에 높은 관심을 보이었다. 이러한 연구 결과를 바탕으로 실내공기 오염을 개선할 수 있는 식물과 이와 관련된 정보 제공을 용이하게 도울 수 있는 복합적 기능의 식물 애플리케이션의 필요성을 제안하고자 한다.

부산지역 4개 백화점의 공기오염도에 관한 조사연구 (The Study on the Level of Air Pollution at Four Department Stores in Pusan Area)

  • 문덕환;이현우;이채언
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF