Browse > Article
http://dx.doi.org/10.5322/JES.2008.17.9.1005

The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area  

Son, Bu-Soon (Department of Environmental Health Science, Soonchunhyang University)
Song, Mi-Ra (Department of Beauty Design, Dongshin University)
Kim, Jung-Duk (Department of Environmental Health Science, Soonchunhyang University)
Cho, Tae-Jin (Department of Environmental Health Science, Soonchunhyang University)
Yang, Won-Ho (Department of Occupational Health, Catholic University of Daegu)
Chung, Tae-Woong (Department of Earth & Environmental Science, Sejong University)
Publication Information
Journal of Environmental Science International / v.17, no.9, 2008 , pp. 1005-1013 More about this Journal
Abstract
In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.
Keywords
$PM_{10}$; Heavy metal; Air quality of indoor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lee S. C., Chang M., 2000, Indoor and outdoor air quality investigation at schools in Hong Kong, chemosphere, 41, 109-113   DOI   ScienceOn
2 Kim Y. S., 1999, A Study on the Indoor Air Pollution Levels in the Schools, Korean Society For Health Education And Promotion, 110-114
3 Kim S. W., 1997, Source Characterization and Concentration of Chemical Elements in Fine Particulate in An Industrial Area, Master Dissertation, Graduate School of Env. Studies, Hanyang University, Seoul
4 Nam B. H., Hwang I. J., Kim D. S., 2000, Classification of PM-10 in indoor Air Using Pattern Recogntion, Atmos. Env., 141-142
5 Lee T. K., 2002, A Study on the Characterization of Indoor Air Pollution and Management, Master Dissertation, Graduate School of Education, Yong In University, Yongin
6 Son B. S., 1998, Indoor Air Pollution, ShinKwang, Inc
7 Kim Y. S., 1995, Health effect of Indoor Air Pollution, Air-Conditioning And Refrigerating Engineers Of Korea , 24(1): 29-32
8 Bae Y. J., Kim K. H., Chon H. T., An J. S., 1998, Heavy Metal Concentrations of Indoor and Outdoor Dusts -In Middle Schools in the Kangseoku and Yangchonku Areas, Seoul-, Korean Earth Science Society, 19(5), 449-460
9 Son J. R., Byeon S. H., Kim Y. H., Kim J. H., Cho Y. S., Lee J. Y., Park Y. J., 2003, Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul, Korean Society For Sanitation, 18(3), 101-110
10 Kim J. W., 2000, A Study on the Indoor Air Pollution Levels in the Classrooms at Public Schools, Master Dissertation, Dept. of Environmental Engineering, Ajou University, Suwon
11 EPA, 1995, Indoor air Quality(IAQ) Tools For Schools, IAQ Coordinator's Guide, 1-78
12 Shin E. S., Choi M. K., Sun W. Y., Chung Y. S., 2002, Trace Elments Characterization of $PM_{10}$ in Seoul Area, Atmos. Env., 18(5), 363-372
13 Shin D. C., Yang J. Y., Lim Y. W., Kim H. H., Park S. E., Hong C. S., 2003, Influence of indoor pollution in habitants health and development of the model of healthy home environment, Atmos. Env., 35, 69-70
14 Shin E. S., Kim J. W., 2002, A Study on the Indoor Air Pollution Levels in the Classrooms at Public Schools in Suwon, Korean Society For Sanitation, 17(1), 20-27