• Title/Summary/Keyword: indoor air pollutants

Search Result 308, Processing Time 0.028 seconds

Evaluation of Volatile Organic Compounds Levels in Industrial Complex and Nearby Residential Areas of Daegu (대구지역 공단과 인근 주거지역의 휘발성유기화합물질 오염도 평가)

  • Jo, Wan Geun;Lee, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.519-525
    • /
    • 2004
  • Air pollution from the Daegu industrial complex (Die) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the ODIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94-0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.

Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul (서울시 일부 학교의 실내 공기질 조사 및 인식도 평가)

  • Sohn, Jong-Ryeul;Byeon, Sang-Hoon;Kim, Young-Whan;Kim, Jong-Hyeok;Cho, Yun-Su;Lee, Jae-Young;Park, Youn-Ju
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

The metal corrosion caused by museum indoor air pollutants (박물관 실내 대기오염물질에 의한 금속 부식 영향)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.5-14
    • /
    • 2008
  • The effect of air pollutants coming from internal museum materials such as wood-based products and cements on metal corrosion have been investigated. The Oddy test and the Chamber test was employed as a corrosion test. The metal pieces after the Oddy test had different corrosion types caused by the internal museum materials. The most effective wood based product was 18T HS(E0) and 9mm plywood(F0,E0). Iron(Fe) and copper(Cu) also bronze of the Chamber test had corrosion caused by Formic acid, Acetic acid, and Acetaldehyde. The packing materials in high humidity had caused more corrosion on the surface of the metal pieces than in low humidity.

  • PDF

A Study on Indoor Air Pollutants Reduction Effect by Plants per Season (식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구)

  • Song, Jeong Eun;Kim, Yong Shik;Sohn, Jang Yeul
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

DEVELOPMENT OF A COMPUTER CODE FOR PREDICTION OF INDOOR POLLUTANT DISPERSION (새집증후군 저감대책을 위한 실내 오염물질 확산 해석 코드 개발)

  • Jeon, H.J.;Yang, K.S.;Choi, C.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.508-516
    • /
    • 2010
  • An efficient code has been developed to predict dispersion of indoor air pollutants The computing capability of the code has been compared with that of a commercial code inn a benchmark test. After that, the code has been employed to compute dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and scalar fields. LES has bee regarded as an academic tool, but the newly-developed code reveals a possibility of application of LES to practical problems, especially dispersion of indoor pollutants.

  • PDF

Tendency of the indoor pollutants along with increased dwelling period at new apartments (거주기간 증가에 따른 신축 공동주택의 실내오염도 변화추이)

  • Jang, Seong Ki;Ryu, Jung Min;Seo, Soo Yun;Lim, Jung Yeon;Lee, Woo Seok
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.453-459
    • /
    • 2007
  • This study is for investigation of indoor conditions with air contamination after occupation 120 households in brand-new apartments by measuring the concentration of VOCs and carbonyl compounds. It has been found that TVOC (total volatile organic compounds; TVOCs) were $688.61{\mu}g/m^3$ after moving in. And formaldehyde, toluene, m, p-xylene, acetone and ethylbenzene were $158.56{\mu}g/m^3$, $146.58{\mu}g/m^3$, $69.28{\mu}g/m^3$, $63.80{\mu}g/m^3$ and $29.65{\mu}g/m^3$, respectively. The mean concentrations of indoor air pollutants tend to decrease along an increase dwelling period. But, the mean concentration of d-limonene increased from 2 months to 10 months. Also, toluene, ethylbenzene, m, p, o-xylene amounted to 38.8 % among VOCs studied, this ratio tend to decrease along with and increased dwelling period.

A Study on Emission Characteristics of Carbonyl Compounds for Indoor Air in New Apartment (신축공동주택의 실내공기 중 카보닐화합물의 방출특성에 관한 연구)

  • Ryu, Jung-Min;Cho, Tae-Jin;Jang, Seong-Ki;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.807-818
    • /
    • 2010
  • The study is about variations in Carbonyl compounds concentration within apartment buildings according to pre-residence and residence. We consecutively investigated indoor air pollutants in 120 households in 6 cities at pre-residence and residence. Carbonyl compounds were collected using the 2,4-DNPH cartridge and were analyzed using HPLC. The carbonyls concentration of indoor air in the new apartments before occupation measured formadlehyde($76.0\;{\mu}g/m^3$), acetone($85.9\;{\mu}g/m^3$), acetaldehyde($13.8\;{\mu}g/m^3$). The carbonyls concentration of indoor air in the new apartments after occupation measured formadlehyde($233.1\;{\mu}g/m^3$), acetone($128.9\;{\mu}g/m^3$), acetaldehyde($29.8\;{\mu}g/m^3$), respectively. As a result, the mean concentration of carbonyl compounds within the pre-occupancy stage was lower than those of residence.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process (연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구)

  • 이주상;김신도;김광영;김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.