• 제목/요약/키워드: indoor air environment

검색결과 1,061건 처리시간 0.022초

대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성 (Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area)

  • 백성옥;송희봉
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

EFFECT OF INTRENAL PARTITIONING ON INDOOR AIR QUALITY IN A ROOM

  • Lee, Heekwan;Hazim B. Awbi
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 춘계학술대회 논문집
    • /
    • pp.155-157
    • /
    • 2000
  • In modem buildings, the concept of open-space plan gets more acceptance as it supports more flexibility for the internal space design. This open-space can be easily subdivided by internal partitioning to provide each individual working zone. Although the partitioning forms each physical working zone, its indoor environment could be different Iron what the occupants require. Especially the air movement and contaminant spread in each working zone could be blocked or distorted by the partitioning, which may produce unexpected change in ventilation performance designed. (omitted)

  • PDF

하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 - (A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions -)

  • 정상열;고경태
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1997년도 추계총회 및 학술발표회 논문집
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

공동주택의 겨울철 실내공기환경에 대한 거주자 반응 (Resident's Subjective Responses to Indoor Air quality of Multi Family Houses in Winter)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제35권2호
    • /
    • pp.173-186
    • /
    • 1997
  • The purpose of this study is to find out understand the resident's subjective responses to physical indoor environment. The questionnaire survey was carried out to measure form Jan. 8th to Feb. 2th in 1996, the typical external climate of winter in Korea. The subjects were four hundred and eleven housewives, living in apartments of RC structure I Ilsan apartment complex. As the result, residents usual ventilate once or twice a day by opening outward windows for about ten minutes. Unpleasant smell producted by cooking and wet garbage made most of them negatively respond to kitchen's air quality. regression analysis of relativeness between sense of air freshness smell, dust and comfort revealed that sense of comfort was the most highly related with the extent of bad smell. Housing factors such as size of apartments and ventilating, smoking and gas usage had significant effects on indoor air quality and the subjective responses in winter. Therefore it is especially important to consider air pollution problem from the beginning stage when planning small apartments. It is required that the government of environment has to emphasize the importance of ventilation to residents, and makes an effort to establish the design criteria on indoor air quality in house.

  • PDF

철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 - (Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity -)

  • 박덕신;배상호;정병철;이주열
    • 한국철도학회논문집
    • /
    • 제6권1호
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.

바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성 (Characteristics of VOCs and Formaldehyde Emitted from Floorings)

  • 박현주;장성기;서수연;임준호
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

Applied Horticultural Biotechnology for the Mitigation of Indoor Air Pollution

  • Torpy, Fraser R.;Pettit, Thomas;Irga, Peter J.
    • 인간식물환경학회지
    • /
    • 제21권6호
    • /
    • pp.445-460
    • /
    • 2018
  • Exposure to indoor air pollution is an emerging world-wide problem, with growing evidence that it is a major cause of morbidity worldwide. Whilst most indoor air pollutants are of outdoor origin, these combine with a range of indoor sourced pollutants that may lead to high pollutant levels indoors. The pollutants of greatest concern are volatile organic compounds (VOCs) and particulate matter (PM), both of which are associated with a range of serious health problems. Whilst current buildings usually use ventilation with outdoor air to remove these pollutants, botanical systems are gaining recognition as an effective alternative. Whilst many years research has shown that traditional potted plants and their substrates are capable of removing VOCs effectively, they are inefficient at removing PM, and are limited in their pollutant removal rates by the need for pollutants to diffuse to the active pollutant removal components of these systems. Active botanical biofiltration, using green wall systems combined with mechanical fans to increase pollutant exposure to the plants and substrate, show greatly increased rates of pollutant removal for both VOCs, PM and also carbon dioxide ($CO_2$). A developing body of research indicates that these systems can outperform existing technologies for indoor air pollutant removal, although further research is required before their use will become widespread. Whilst it is known that plant species selection and substrate characteristics can affect the performance of active botanical systems, optimal characteristics are yet to be identified. Once this research has been completed, it is proposed that active botanical biofiltration will provide a cheap and low energy use alternative to mechanical ventilations systems for the maintenance of indoor environmental quality.

옥상녹화에 따른 콘크리트 건축물의 열환경 개선효과 -일사차폐블록과 잔디를 대상으로- (Study on Improvement of Thermal Environment by Green Roof Systems on RC Building - utilization of solar insulating block and the grass -)

  • 박찬필;후루가와 노부히사
    • 한국환경복원기술학회지
    • /
    • 제7권1호
    • /
    • pp.1-9
    • /
    • 2004
  • Caused on the excessive heat accumulation of concrete material, the indoor thermal environment of reinforced concrete building is so bad in Okinawa. As the interruption of solar radiation could be one of the methods to improve it, the purpose of this study is to find out the effect of adopting solar radiation interrupting materials -Solar insulating block, Grass, and both of them- for the improvement of thermal environment. As the result, it was found that grass on the solar insulating block which has an air layer obviously improved the indoor thermal environment of RC building which was applied to. And it was found that the systems have an effectuality on heat island phenomenon simultaneously. It could be proposed as a good system which improve the indoor thermal environment of the existent houses.

기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석 (An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units)

  • 유복희
    • 한국주거학회논문집
    • /
    • 제21권6호
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.