• Title/Summary/Keyword: indoor air

Search Result 2,342, Processing Time 0.023 seconds

A Survey on the Indoor Temperature and Power Consumption of Domestic Refrigerator (가정용 냉장고의 고내온도 및 전력소비 실태조사)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.357-366
    • /
    • 2018
  • In this study, if the set temperature of the refrigerator differs from the set temperature of the refrigerator, the temperature distribution of food in the refrigerator is estimated by measuring the temperature in the refrigerator and in the refrigerator room. In addition, based on the set temperature of the refrigerator and the freezer, the temperature range of the heat is large and the time required to recover to the set temperature is to be determined. And the optimal setting temperature for home refrigerators is to be shown by measuring the amount of power consumed to recover to the set temperature. As a result, the conditions in which the temperature in the freezer realized $-18^{\circ}C$ were only appropriate in case 3, Case 6, Case 8, and Case 9 when the set temperature in the refrigerator was lower than that in the freezer. Under these conditions, the minimum temperature in the refrigerator was $-1.1^{\circ}C$, Case 6 was $-1.5^{\circ}C$, Case 8 was $-1.1^{\circ}C$ and Case 9 was $-0.8^{\circ}C$, respectively. Also, the total power consumption during the 10 hours operation time of each case was greater than the setting temperature of the freezer and the refrigerator except case 4, since case 4 started operation around 13:30 in the morning.

Adsorption of Formaldehyde by Wood Charcoal-Based Building Materials (목탄계 건축자재에 의한 포름알데히드 흡착)

  • Lee, Oh-Kyu;Choi, Joon-Weon;Jo, Tae-Su;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.61-69
    • /
    • 2007
  • The building materials used for improving indoor air quality, the wood charcoal mixed with cement mortar or natural water paint were examined for their potential removing ability of formaldehyde. After the reaction of samples with formaldehyde in the glass flasks designed in our lab, the remaining formaldehyde was collected using DNPH (2,4-dinitrophenyl hydrazine) cartridges, and their concentration was determined using HPLC. From the results, it was found that the removing amount of formaldehyde per one gram sample containing 5, 10, or 15% of wood charcoal was more than three times compared to that of control (100% cement mortar or water paint). Their elimination percentages from the initial formaldehyde was about 80~90%. The experimental results for wood charcoal-water paint showed a similar trend with those of wood charcoal-cement mortar samples. Their elimination percentages from the initial formaldehyde was about 90%. It is proposed that formaldehyde is adsorbed on the adsorbed 'O' or 'OH' groups in the graphene layers formed through the re-arrangement of lignocellulose in the wood during the carbonization procedure.

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

Analysis and Suggestion of Environment-friendly Interior Finishing Materials for Aged Apartment Remodeling (노후 공동주택 리모델링의 친환경 실내 마감재료 분석 및 제안)

  • Kim, Ki-Hyun;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.2
    • /
    • pp.118-126
    • /
    • 2007
  • Environmentally Sound and Sustainable Development (ESSD)" is a key word in recent years. The construction industry, have put a great influence on ergonomic and sustainable environment. Recently, "green building certifications", such as Indoor Air Quality (IAQ) and eco-friendly material regulation have been established. With this regard, new construction and aged-housing remodeling projects are required to meet these certification criteria. Apartment residents have great concern on eco-product, since many cases are reported that Sick Building Syndrome is caused by toxic substance from building materials. Aged-housing remodeling construction has a unique characteristic in that the residents are already determined prior to construction execution. Therefore, the analysis of resident's need for building materials in aged-housing remodeling is relatively easy compared to new building construction. As such, it is very important to analyze their preferences for eco-friendly materials prior to project execution. The purpose of this study is to find the needs of residents and priority of their needs. Based on their needs and priority, this paper provides a new strategy in using environment-friendly materials and maximizing their satisfaction level when aged housing remodeling is constructed. In addition, this paper provide new criteria in selecting new developed environmental materials in remodeling projects for the purpose of improving the safety and health level in construction industry.

Size measurement of electrosprayed droplets using shadowgraph visualization method (Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정)

  • Oh, Min-Jeong;Kim, Sung-Hyun;Lee, Myong-Hwa
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.151-158
    • /
    • 2017
  • Electrostatic precipitator is widely used to remove particulate matters in indoor air and industrial flue gas due to low pressure drop and high collection efficiency. However, it has a low collection efficiency for the submicrometer sized particles. Electrospraying is a potential method to increase the particle charging efficiency, which results in increased collection efficiency. Although particle charging efficiency is highly dependent upon droplet size, the effective measuring method of the droplets is still uncertain. Tap water was electrosprayed in this study, and the images of electrosprayed droplets were taken with a high speed camera coupled with several visualization methods in order to measure the droplets size. The droplet size distribution was determined by an image processing with an image-J program. As a result, a droplet measured by a laser visualization, had a half size of that by a Xenon light visualization. In addition, the experimentally measured droplet sizes were a good agreement with the predicted values suggested by $Fern{\acute{a}}ndez$ de la Mora and Loscertales(1994).

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.