• Title/Summary/Keyword: in-situ 상태

Search Result 334, Processing Time 0.031 seconds

A study of in situ immobilization of lipase by using an LC column with aldehyde-silica stationary phase

  • Seo, U-Yong;Hong, Seon-Hui;Lee, Gi-Se
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.633-634
    • /
    • 2001
  • The in situ immobilization of lipase in an LC column with aldehyde-silica stationary phase was optimized. The effects of feed composition, temperature, mobile phase pH and now rate on immobilization efficiency were investigated. Lipase activity after in situ immobilization was compared with free enzyme and batch immobilized enzyme.

  • PDF

Analysis of Parameters to Influence on Rock Fragmentation in Bench Blasting (벤치발파에서 암석 파쇄도에 영향을 미치는 요인 분석)

  • 최용근;이정인;이정상;김장순
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.1-12
    • /
    • 2004
  • In bench blasting, rock fragmentation is one of the most important factors determining productivity. Rock fragmentation could be affected by various conditions and these were hewn that rock joint conditions and in-situ block sizes were the biggest effect on it. This research is focused on what or how to influence on rock fragmentation according to relation between blasting conditions and the in-situ rock conditions such as rock joint conditions and in-situ block size. Field measurements were carried out in 3 open pit limestone mines, where in-situ rock conditions and blasting conditions were fully investigated. The results show that the parameters interact with blasting conditions complicatedly and especially in-situ block size has bigger effects. Dip direction of major joint set also can affect on fragmentation. Mean fragment size become smallest when dip direction of major joint set is about $30^{\circ}$ with the bench direction. The reason is considered to be come from difference of propagation paths of elastic wave.

On the in situ Measurement Method of Headphones using Head And Torso Simulator (HATS를 이용한 헤드폰의 in situ 측정방법에 관하여)

  • Kang, Kyeong-Ok;Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.15-27
    • /
    • 1992
  • The standard measuring method of the frequency characteristics of headphones has been needed because different results come from the different measuring methods because of the lack of the reasonable measuring method of headphone characteristics, for example, in the case of psycho-acoustic experiments with headphones. In this paper, based on this fact, we studied the measurement method of headphones based on the natural hearing condition of human being, that is in situ measuring method, by measuring the headphone frequency characteristics using an artificial ear and a newly proposed device, HATS(Head And Torso Simulator). From the result of this paper, we could see that the method appropriate to a so called in situ condition was the one wi9th HATS, Because HATS simulated more correctly the acoustic impedance of the ear and the diffraction effect of the human head than the artificial ear.

  • PDF

Process Development for in-situ Transverse Orientation of TLCP Fibril in PC/TLCP Blends (액정고분자 복합계의 in-situ 횡단면 배향을 위한 공정개발)

  • 이재욱
    • The Korean Journal of Rheology
    • /
    • v.10 no.2
    • /
    • pp.82-91
    • /
    • 1998
  • 액정고분자/폴리카보네이트 혼합계로 구성된 분자복합계를 쉬트상으로 가공할 때 취 약해지기 쉬운 횡단면 방향의 물성을 향상시키기 위하여 미세섬유상의 배향을 in-situ 상태 로 적절히 제어할수 있는 Simultaneous Convergent-Divergent(SCD) 다이를 설계·제작하 고 압출실험을 수행하여 얻은 압출 쉬트를 대상으로 구조-물성-가공의 상관관계를 조사하 였다. 액정고분자의 첨가 함량에 따른 토오크와 토출량의 변화는 액정고분자를 10wt% 소량 첨가하였음에도 현저한 감소 효과를 보였으며 약 30wt%일 때 최소로되었다. 이는 액정고분 자가 보강 기능외에 가공특성의 개선에도 큰 효과가 있어 가공조제로서의 가능성을 보이는 결과로 혼합계의 유변학적 특성 결과에서도 확인할수 있었다. 또 DSC와 DMA를 이용한 열 분석 결과 액정고분자의 함량이 증가함에 따라 PC의 유리전이온도가 다소 감소하는 현상을 보임에 미루어 이 혼합계는 부분적으로 상용성을 갖는 것으로 볼수 있으며 모폴로지 분석을 통해서도 이를 확인할수 있었다. TLCP/PC 혼합계로 구성되는 분자복합재를 SCD 다이를 사용하여 제조한 압출 쉬트의 방향성에 따른 기계적 물성은 기존의 쉬트 다이보다 흐름방향 으로는 다소 낮은 물성치를 보이지만 횡단면 방향으로는 물성이 현저히 향상됨을 관찰할수 있었다. 모폴로지 분석결과 기존의 쉬트 다이의 경우 벽면 부근에서는 액정고분자가 미세섬 유상으로 형성되어 흐름방향으로 배향되어 있지만 중심부에서는 액정 상태로 존재하는 반 면, SCD 다이의 경우 미세섬유상으로 형성된 액정고분자가 벽면에서부터 중심부로 갈수록 횡단면 방향으로 서서히 배향되어 있음을 확인할수 있었다.

  • PDF

Capacitive Sensor for in situ Measurement of Deterioration of Car Engine Oil (자동차 엔진오일 열화상태 in situ 측정용 전기용량 센서)

  • Lee, R.D.;Kim, H.J.;Semenov, Yu. P.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.266-272
    • /
    • 2001
  • A coil-type capacitive sensor on which the deterioration of the car engine oil can be in situ measured, has been developed. The sensor was designed to get over 10 pF at the limited space on the drain hole of the oil pan. The design factors for stable capacitance measurement such as coil diameter and winding condition, materials and configuration of the coil former, and shielding method, etc., were known by both computer simulation and experimental investigations. The dielectric properties measured by several sensors for an used sample oil were consisted within 0.25%. The sensor installed on the car having severe vibration, temperature and humidity fluctuation, even electromagnetic noise, has shown very distinguishable results.

  • PDF

In-situ EQCM Study on Growth of Polypyrrole Films Using Gold Electrodes Modified with Self-Assembled Monolayers in an Aqueous Solution (자기 집합 단분자막 개질 금 전극을 이용한 수용액 중 폴리피를 성장에 관한 In-situ EQCM 연구)

  • Seo, Kyoung--Ja;Jeon, Il-Cheol
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.3
    • /
    • pp.143-152
    • /
    • 2002
  • The growth of Polypyrrole film has been investigated during electropolymerization in an aqueous solution on bare and SAM modified gold electrodes by in-situ EQCM and ex-situ AFM. According to the result of cyclic voltammetry measurements, in the case of a bare gold electrode, the electrochemical deposition of polypyrrole were dependent on the limiting oxidative potential, but not on scan numbers. When the limiting potential higher than 0.8 V was applied on the electrode, the amount of polypyrrole deposited on a gold electrode was rapidly increased and the abnormal mass change attributed to the rearrangement of polypyrrole films was observed as the scan number increased. The polypyrrole film Prepared on electrodes modified with 1-dodecanethiol SAM or thiophene SAM grew 3-dimensionally with the rearrangement of film. However, in the case of BPUS SAM, 2-dimensional layer-by-layer growth of film was observed without the rearrangement of film. AFM images showed films with chain-shaped and/ or donut-shaped polymers when grown rapidly and a wrinkled film at the steady state condition.

Investigation of the Performance Characteristics of an In-Situ Particle Monitor at Low Pressures Using Aerodynamic Lenses (저압상태에서 공기역학적 렌즈를 이용한 In-Situ Particle Monitor의 성능특성 분석)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1359-1367
    • /
    • 2000
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at low pressures has been studied. We generated the uniform sized methylene blue particle beams using three identical aerodynamic lenses in the center of the vacuum line, and measured the detection efficiency of the ISPM. The effects of particle size, particle concentration, mass flow rate, system pressure, and arrangement of aerodynamic lenses on the detection efficiency of the ISPM were examined. Results show that the detection efficiency of the ISPM greatly depends on the mass flow rate, and the particle Stokes number. We also found that the optimum Stokes number ranges from 0.4 to 1.9 for the experimental conditions.

Elli-Situ 2000 (in situ, 실시간 표면 및 박막 모니터 장비)

  • 방현용;주한용
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.46-46
    • /
    • 2000
  • 과학기술 및 산업의 발달로 인하여 실험 중 또는 공정 상에서 in situ, 실시간으로 측정하고 분석하며 이를 되먹임하는 품질제어의 중요성이 대두되고 있다. 반도체 공정 또는 박막제조 공정 중에서 박막의 두께, 굴절율, 물질의 조성비 등을 알아내는 것이 긴요한 과제로 대두되고 있으며, 이를 위하여 공정중인 제품의 품질을 실시간으로 평가하는 장비가 요구되고 있는 것이다. 나아가 공정중의 예상하지 못한 시료의 특성변화를 그대로 감지하여 적절히 보정해 주는 되먹임 기법은 높은 수율을 보장하는 첨단기법이라 할 수 있다. 이러한요구에 부응할 수 있는 본 제품(Elli-situ 2000)은 박막의 두께 표면변화를 sub 의 정밀도를 가지고 in situ, 실시간으로 정밀 측정할 수 있는 첨단 계측장비로서 빛의 편광상태 변화를 측정하기 때문에 공정 중의 시료에 영향을 주지 않는 비간섭 특성과 비접촉 특성의 장점 뿐만 아니라 공기중에서는 물론 진공이나 액체 등의 매질에서도 사용될 수 있어서 매질에 대한 제약이 거의 없다는 장점도 가지고 있다. 편광상태의 제어 및 측정을 필요한 광학장비의 경우, 제작이 까다롭기 때문에 대부분 가격이 높은 편이고 사용방법이나 측정 데이터에 대한 해석이 어렵다는 단점이 있으나, Elli-situ 2000의 경우 상용화된 외국제품(국내제품은 없슴)과 비교하여 성능 및 가격경쟁력에 있어서도 우위에 있으며 간단, 명료한 장비조작 및 컴퓨터를 사용한 구동의 전자동화를 이룸으로써 초보자도 쉽게 측정하고 데이터를 처리할 수 있도록 하였다. 또한 취부대의 경우, 진공포트 플랜지의 표준규격(2-3" Del-Seal 플랜지 규격)에 맞춤으로써 기존의 진공챔버에 부착하여 진공에 전혀 영향을 주지 않는 상태에서 시료의 변화를 in situ, 실시간으로 정밀 측정할 수 있도록 하였다. 하였다.O 박막은 산소 가스압력과 기판온도, 인가 전류를 변화시켜가며 증착하였으며 이에 따른 박막의 결정성 변화를 알아보았다. 기판온도를 실온에서 점차 증가시켜나가면 $\Delta$$\theta$50은 급격히 감소하며 30$0^{\circ}C$에서는 결정성이 우수한 막을 얻을 수 있었다. 또한 산소 가스 압력이 0.5~1mTorr에서 $\Delta$$\theta$50은 양호한 값을 나타내었지만 그 이상에서는 c-축 배향성이 나빠짐을 확인하였다. 따라서 대향타겟식스퍼터 장치를 이용하여 ZnO 박막을 증착시 가스압력 0.5~1mTorr, 기판온도 20$0^{\circ}C$이상의 막 제작조건에서 결정성이 우수하게 나타나는 것을 확인할 수 있었다. gluten이 단단해졌음을 알수 있었다. 유화제 stearly 칼슘, 혹은 hemicellulase를 amarans 10% 대체한 밀가루에 첨가하면 확연히 비용적을 증대시킬 수 있다는 사실을 알 수 있었다. quinoa는 명아주과 Chenopodium에 속하고 페루, 볼리비아 등의 고산지에서 재배 되어지는 것을 시료로 사용하였다. quinoa 분말은 중량의 5-20%을 quinoa를 대체하고 더욱이 분말중량에 대하여 0-200ppm의 lipase를 lipid(밀가루의 2-3배)에 대하여 품질개량제로서 이용했다. 그 결과 quinoa 대량 7.5%에서 비용적, gas cell이 가장 긍정적 결과를 산출했고 반죽의 조직구조가 강화되었다. 또 quinoa 대체에 의해 전분-지질 복합제의 흡열량이 증대된 것으로부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다. 이것은

  • PDF

Performance Characteristics of In-Situ Particle Monitors at Sub-Atmospheric Pressure (감압상태에서의 In-Situ Particle Monitor의 성능특성)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1564-1570
    • /
    • 1998
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at subatmospheric pressures has been studied. We created uniform upstream conditions of particle concentration and measured the detection efficiency, the lower detection limit, and the size response of the ISPM using uniform sized methylene blue aerosol particles. The effect of particle size, particle velocity, particle concentration, and system pressure on the detection efficiency was examined. Results show that the detection efficiency of the ISPM decreases with decreasing chamber pressure, and with increasing mass flow rate. The lower detection limit of the ISPM, determined at 50 % of the measured maximum detection efficiency, was found to be about $0.15{\sim}0.2{\mu}m$, which is similar to the minimum detectable size of $0.17{\mu}$ given by the manufacturer.