• Title/Summary/Keyword: in-site waste soil

Search Result 154, Processing Time 0.025 seconds

Bearing Capacity and Environmental Assessment on Ground with By-product Lime (부산석회 재활용 부지에 대한 지지력 및 환경영향 평가에 관한 연구)

  • Chung, Ha-Ik;Hong, Seung-Seo;Lee, Yong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.897-903
    • /
    • 2004
  • Waste lime used in this study is producted as a by-product in the manufacturing process of making $Na_2CO_3$ from local chemical factory in Incheon. Currently about 320 millon tons of waste lime are accumulated and annually 100,000 tons are producted. Reuse of waste lime mixed with soil for banking and backfill materia in civil works was analysed in this study. This study was Carried out to investigate the geotechnical and environmental characteristics on field application. Field investigations were conducted on the road construction site in Incheon. This study presents the results of the engineering characteristics in field test and the leaching characteristic of waste lime in laboratory column tests. Countermeasure for reduction of environmental effects was suggested from the test results.

  • PDF

A Study on the Selection of Compaction Method in Order to Utilize the Waste Landfill Selected Soils (폐기물매립장 선별토사 활용을 위한 다짐공법 선정에 관한 연구)

  • Nam, Hong-Ki;Lee, Seung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.29-40
    • /
    • 2017
  • In this study, the dynamic compaction method was selected by analyzing field situation, soil condition data and compaction test characteristics of the special selected soils, and the compaction method for using the selected soils as the site restoration soil of the ${\bigcirc}{\bigcirc}$ city non-sanitary landfill maintenance project. The N value in the standard penetration test (SPT) before and after dynamic compaction increased by an average of 89% over the range 12~18, and the allowable bearing capacity of the plate bearing test (PBT) was ranged $150{\sim}227kN/m^2$, at least 80% higher than that before test. As a result, it can be seen that the same tendency as the dynamic compaction effect applied to the existing dredging and waste landfill is shown.

Distribution of Metallic Elements Contamination in River Deposits and Farmland in the Vicinity of an Abandoned Korean Mine (폐광산 인근 농경지 및 하천 퇴적토의 중금속 오염 특성)

  • Lee, Hwan;Lee, Yoonjin
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.133-145
    • /
    • 2020
  • Soil in mine waste-rock fields, and at the pithead, sediments and farmlands around an abandoned mine in the Chungcheong Province of South Korea were investigated to assess the distribution of metallic elements and to understand the scope of the pollution. Reddening was observed from the mine up to a distance of 61 m. Losses of waste rock around the mine were assessed over a section of 1800 ㎥. Yellowish precipitates on the bottom of a stream were identified as ferrihydrite and goethite. For anions, a mean sulfate ion level over 773.6 mg/L was found during August in the river water samples. Mine drainage at the site was shown to have a pH of 4.9 and a sulfate concentration of 1557.8 mg/L during the August rainy season. A possible cause of the metallic element contamination in the mine is waste-rock loss, because mine waste-rock is located on the slope in this area. In conclusion, the total soil area to be treated, based on the amount that exceeded the recommended Korean soil pollution levels, was assessed to be 10,297 ㎡.

A Study on Pre-Red Mud and Bio-Solids Applicability as Soil Stabilizer (Pre-Red Mud 및 Bio-Solids의 토양 안정화제 활용 가능성에 대한 연구)

  • Yang, Joo-Kyung;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.419-428
    • /
    • 2011
  • Recycling as a stabilizer of industrial by-product can be terms of the proper handling of industrial by-product and positive side in terms of recycling of waste. This study was performed to evaluate has the possibility as stabilizer by primary processing Pre-Red Mud and Bio-Solids which are generated as waste in soils contaminated with heavy metals and compared the efficiency with steel slug being applied in an existing site. In evaluation of the arsenic-fixing ability of stabilizer in batch test, Bio-Solids have the similar arsenic-fixing ability with Pre-Red Mud, which shows 17% h igher arsenic-fixing ability than PS Ball. Since the stabilization periods using Bio-Solids and Pre-Red Mud are faster than the PS Ball, they seems to be better stabilizer than PS Ball to decrease the leaching of arsenic in contaiminated soil.

Source Identification of Heavy Metal Contamination at an Industrial Complex Established Using Construction Wastes (건설폐기물을 성토재로 사용한 산업단지에서의 중금속 오염 원인 규명)

  • JOO, Gwonho;KIM, Kibeum;NAM, Kyoungphile;JUNG, Jae-Woong;Moon, Seheum;CHOI, Yongju
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2018
  • This paper is aimed at source tracking of soil heavy metal contamination at a site established by reusing construction wastes. The soil heavy metal concentration at the study site peaked at a depth range of 5-10 m. Column studies were conducted to investigate the possibility of the contamination scenario of infiltration of stormwater carrying heavy metals of ground origin followed by selective heavy metal accumulation at the 5-10 m depth range. Almost all amount of lead, zinc, cadmium, and nickel introduced to the columns each packed with 0-5 m or 5-10 m field soil were accumulated in the column. The very poor heavy metal mobility in spite of the weak association of the heavy metals with the soil (characterized by a sequential extraction procedure) can be attributed to the high pH (10-11) of the construction wastes. From the results, the heavy metal contamination of the subsurface soil by an external heavy metal source was determined to be very unlikely at the study site. The column study applied in the current study is expected to be a useful methodology to present direct evidence of the contaminant source tracking at soil contamination sites.

Study on the Experiences of Subsurface Soil Remediation at Commercial Nuclear Power Plants in the United States (미국 원전의 심층토양 제염사례 연구)

  • Lee, Hyoung-Woo;Kim, Ju-Youl;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.213-226
    • /
    • 2019
  • Regulatory agency and licensee are preparing for the site restoration of Kori unit 1, the first commercial NPP in Korea, scheduled for 2031. Developing regulatory guidelines and strategies is essential for effective restoration work. Unfortunately, Korea does not have experience of site restoration of commercial NPPs. Therefore, it is important to review cases from experienced countries to establish a strategy and regulatory standards. The U.S. has had numerous soil remediation experiences using RESRAD and MARSSIM. However, formalized evaluation methodologies for subsurface soil have not yet been established in MARSSIM. This survey focused on subsurface soil remediation by reviewing the five decommissioned NPPs under regulation of the US NRC. Overall process of remediating a contaminated subsurface soil and groundwater was reviewed to identify considerations and lessons that could be applicable in Korea. In addition, an applied methodology for evaluation of contaminated subsurface soil and related major issues between regulatory agency and licensees were reviewed in detail to support establishment of remediation strategy for Kori unit 1.

The impact of municipal waste disposal of heavy metals on environmental pollution: A case study for Tonekabon, Iran

  • Azizpour, Aziz;Azarafza, Mohammad;Akgun, Haluk
    • Advances in environmental research
    • /
    • v.9 no.3
    • /
    • pp.175-189
    • /
    • 2020
  • Municipal solid waste disposal is considered as one of the most important risks for environmental contamination which necessitates the development of strategies to reduce destructive consequences on the ecosystem as related especially to heavy metal accumulation. This study investigates heavy metal (i.e., As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Zn) accumulation in the Tonekabon region, NW of Iran that is related to city waste disposal and evaluates the environmental impact in the Caspian Sea coastal region. For this purpose, after performing field studies and collecting 50 soil specimens from 5 sites of the study area, geochemical tests (i.e., inductively coupled plasma mass spectrometry, atomic absorption spectroscopy and x-ray fluorescence) were conducted on the soil specimens collected from the 5 sites (named as Sites A1, A2, A3, A4 and A5) and the results were used to estimate the pollution indices (i.e., geo-accumulation index, normalized enrichment factor, contamination factor, and pollution load index). The obtained indices were utilized to assess the eco-toxicological risk level in the landfill site which indicated that the city has been severely contaminated by Cu, Mn, Ni, Pb and Zn. These levels have been developed along the stream towards the nearshore areas indicating uptake of soil degradation. The heavy metal contamination was classified to range from unpolluted to highly polluted, which indicated serious heavy metal pollution in the study area as related to municipal solid waste disposal in Tonekabon.

Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site (유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가)

  • Cho, Chang-Hwan;Kim, Joon-Ho;Park, Min-Kyu;Kim, Tae-Hyung;Choi, Yoen-Soo;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.

A geochemical and Geophysical Study on the Environmental contamination in the Vicinity of Waste Dispodal Site (폐기물 매립지 주변지역에서의 환경오염에 관한 지구화학 및 지구물리학적 연구)

  • Kim, Kyoung-Woong;Shon, Ho-Woong
    • The Journal of Natural Sciences
    • /
    • v.8 no.1
    • /
    • pp.87-92
    • /
    • 1995
  • In the Vicinity of the Sindae-dong waste disposal site in Taejon, the average Cu, pb and Zn concentrations in soils are higher than those in other Korean soils but these are not high enough to cause any harmful effect to human and animal through the crop plants. Copper, Pb and Zn are not detected in the groundwater samples and F, Cl, $NO_2$, $NO_3$ and $SO_4$ concentrations in groundwater samples are lower than drinking water standards. However, the pH of groundwater sample in site D is 5.58 which is not suitable for the drinking water. With the electric resistivity method, the water-containg layers are found in contaminated soils and the resistivity values are considerably low because of the dispersion of plume by the leak of leachates. According to the results from the magnetic survey method, the anomalous values of the total geomagnetic fields and their gradients are found in the sampling site of low resistivity and high trace element concentrations.

  • PDF

Evaluation of Goundwater Flow Pattern at the Site of Crystalline Rock using Time Series and Factor Analyses (시계열분석과 요인분석에 의한 결정질 암반의 지하수 유동 평가)

  • Lee, Jeong-Hwan;Jung, Haeryong;Yun, Si-Tae;Kim, Jee-Yeon;Cho, Sung-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.4
    • /
    • pp.12-22
    • /
    • 2014
  • This study evaluated the pattern of groundwater fluctuation in cyrstalline rock using time series and factor analyses. From the results, groundwater level for the 18 wells was classified into 4 types reflecting the hydrogeological properties and rainfall event. Type 1 (DB1-5, DB1-6, DB2-2, KB-10, KB-13) was significantly influenced by groundwater flow through water-conducting features, whereas type 2 (DB1-3, DB1-7, KB-1~KB-3, KB-7, KB-11, KB-14, KB-15) was affected by minor fracture network as well as rainfall event. Type 3 (DB1-1, DB1-2) was mainly influenced by surface infiltration of rainfall event. Type 4 (DB1-8, KB-9) was reflected by the irregular variation of groundwater level caused by anisotropy and heterogeneity of crystalline rock.