• Title/Summary/Keyword: in-position

Search Result 26,502, Processing Time 0.059 seconds

The Theoretical Study of the Measuring Thermal Diffusivity of Semi-Infinite Solid Using the Photothermal Displacement

  • Jeon, PiIsoo;Lee, Kwangjai;Yoo, Jaisuk;Park, Youngmoo;Lee, Jonghwa
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1712-1721
    • /
    • 2004
  • A method of measuring the thermal diffusivity of semi-infinite solid material at room temperature using photothermal displacement is proposed. In previous works, within the constant thickness of material, the thermal diffusivity was determined by the magnitude and phase of deformation gradient as the relative position between the pump and probe beams. In this study, however, a complete theoretical treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in semi-infinite solid materials. The influence of parameters, such as, radius and modulation frequency of the pump beam and the thermal diffusivity, was studied. We propose a simple analysis method based on the zero -crossing position of real part of deformation gradient and the minimum position of phase as the relative position between two beams. It is independent of parameters such as power of pump beam, absorption coefficient, reflectivity, Poisson's ratio, and thermal expansion coefficient.

A Study on the Determination of 3-D Object's Position Based on Computer Vision Method (컴퓨터 비젼 방법을 이용한 3차원 물체 위치 결정에 관한 연구)

  • 김경석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.26-34
    • /
    • 1999
  • This study shows an alternative method for the determination of object's position, based on a computer vision method. This approach develops the vision system model to define the reciprocal relationship between the 3-D real space and 2-D image plane. The developed model involves the bilinear six-view parameters, which is estimated using the relationship between the camera space location and real coordinates of known position. Based on estimated parameters in independent cameras, the position of unknown object is accomplished using a sequential estimation scheme that permits data of unknown points in each of the 2-D image plane of cameras. This vision control methods the robust and reliable, which overcomes the difficulties of the conventional research such as precise calibration of the vision sensor, exact kinematic modeling of the robot, and correct knowledge of the relative positions and orientation of the robot and CCD camera. Finally, the developed vision control method is tested experimentally by performing determination of object position in the space using computer vision system. These results show the presented method is precise and compatible.

  • PDF

AVM Stop-line Detection based Longitudinal Position Correction Algorithm for Automated Driving on Urban Roads (AVM 정지선인지기반 도심환경 종방향 측위보정 알고리즘)

  • Kim, Jongho;Lee, Hyunsung;Yoo, Jinsoo;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.2
    • /
    • pp.33-39
    • /
    • 2020
  • This paper presents an Around View Monitoring (AVM) stop-line detection based longitudinal position correction algorithm for automated driving on urban roads. Poor positioning accuracy of low-cost GPS has many problems for precise path tracking. Therefore, this study aims to improve the longitudinal positioning accuracy of low-cost GPS. The algorithm has three main processes. The first process is a stop-line detection. In this process, the stop-line is detected using Hough Transform from the AVM camera. The second process is a map matching. In the map matching process, to find the corrected vehicle position, the detected line is matched to the stop-line of the HD map using the Iterative Closest Point (ICP) method. Third, longitudinal position of low-cost GPS is updated using a corrected vehicle position with Kalman Filter. The proposed algorithm is implemented in the Robot Operating System (ROS) environment and verified on the actual urban road driving data. Compared to low-cost GPS only, Test results show the longitudinal localization performance was improved.

Torque Ripple Reduction of a PM Synchronous Motor for Electric Power Steering using a Low Resolution Position Sensor

  • Cho, Kwan-Yuhl;Lee, Yong-Kyun;Mok, Hyung-Soo;Kim, Hag-Wone;Jun, Byoung-Ho;Cho, Young-Hoon
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.709-716
    • /
    • 2010
  • MDPS (motor driven power steering) systems have been widely used in vehicles due to their improved fuel efficiency and steering performance when compared to conventional hydraulic steering. However, the reduction of torque ripples and material cost are important issues. A low resolution position sensor for MDPS is one of the candidates for reducing the material costs. However, it may increases the torque ripple due to the current harmonics caused by low resolution encoder signals. In this paper, the torque ripple caused by the quantized rotor position of the low resolution encoder is analyzed. To reduce the torque ripples caused by the quantization of the encoder signals, the rotor position and the speed are estimated by measuring the frequency of the encoder signals. In addition, the compensating q-axis current is added to the current command so that the 6th order torque harmonic is attenuated. The reduction of torque ripples by applying the estimated rotor position and the compensated q-axis current is verified through experimental results.

A study imitating human auditory system for tracking the position of sound source (인간의 청각 시스템을 응용한 음원위치 추정에 관한 연구)

  • Bae, Jeen-Man;Cho, Sun-Ho;Park, Chong-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.878-881
    • /
    • 2003
  • To acquire an appointed speaker's clear voice signal from inspect-camera, picture-conference or hands free microphone eliminating interference noises needs to be preceded speaker's position automatically. Presumption of sound source position's basic algorithm is about measuring TDOA(Time Difference Of Arrival) from reaching same signals between two microphones. This main project uses ADF(Adaptive Delay Filter) [4] and CPS(Cross Power Spectrum) [5] which are one of the most important analysis of TDOA. From these analysis this project proposes presumption of real time sound source position and improved model NI-ADF which makes possible to presume both directions of sound source position. NI-ADF noticed that if auditory sense of humankind reaches above to some specified level in specified frequency, it will accept sound through activated nerve. NI-ADF also proposes practicable algorithm, the presumption of real time sound source position including both directions, that when microphone loads to some specified system, it will use sounds level difference from external system related to sounds of diffraction phenomenon. In accordance with the project, when existing both direction adaptation filter's algorithm measures sound source, it increases more than twice number by measuring one way. Preserving this weak point, this project proposes improved algorithm to presume real time in both directions.

  • PDF

Modified Kalman Filter Method for the Position Estimation of an Autonomous Mobile Robot (자율이동 로봇의 위치추정을 위한 변형된 칼만필터 방식)

  • Eom, Ki-Hwan;Kang, Seong-Ho;Kim, Joo-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.781-790
    • /
    • 2008
  • In order to improve on the divergence by noise convariance in the Kalman filter position estimation, we propose a method of position estimating through compensating the autonomous mobile robot's noise. Proposed method is the modified Kalman filter using neural network. It is prevented the divergence by the estimation of measurement noise covariance and system noise covariance. In order to verify the effectiveness of the proposed method, we performed simulations and experiments for position estimation. The results show that convergence and position error is reduced than the Kalman filter method.

A Study on the Accuracy of Position by GPS at Fixed Station (고정점에서 GPS 측위정도에 관한 연구)

  • Jung, Yun-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.10 no.1
    • /
    • pp.53-62
    • /
    • 1998
  • Accuracy of positions by GPS receiver at Tongyoung Port were measured and analysed in order to get more credible information on GPS positioning for vessels. Positions were automatically recorded every 5-Min from 1st October, 1997 to 30th of November, 1997 by two identical GPS receivers at the Laboratory of Navigation in the College of Marine Science, Gyeongsang University ($34^{\circ}$ 49' 57.985"N, $128^{\circ}$ 24' 06.562") and at the training ship "Gyeongyang" alongside in the tongyoung passenger port ($34^{\circ}$ 50" 10.080"N, $128^{\circ}$ 25' 16.415") as fixed positions. The results are as follows ; 1. Number of the usable satellites observing Zenith angle between $9^{\circ}$ and $82^{\circ}$ was normally 4 during a day 24 hours except for 3 hours with total Number 20. 2. Accuracy of position with time was widely dispersed around center of standard position as well as directional deviation around mean position. 3. Specific error of GPS receiver showed a little deviation by alternative measurements for consecutive 5 days at each fixed position respectively. 4. Accuracy of GPS position at 2 fixed positions of Tongyoung port was revealed 27.2 m as minimum value while normal accuracy for all day could be less than 50 m.

  • PDF

Position Sensorless Control of PMSM Drive for Electro-Hydraulic Brake Systems

  • Yoo, Seungjin;Son, Yeongrack;Ha, Jung-Ik;Park, Cheol-Gyu;You, Seung-Han
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.23-32
    • /
    • 2019
  • This study proposed a fault tolerant control algorithm for electro-hydraulic brake systems where permanent magnet synchronous motor (PMSM) drive is adopted to boost the braking pressure. To cope with motor position sensor faults in the PMSM drive, a braking pressure controller based on an open-loop speed control method for the PMSM was proposed. The magnitude of the current vector was determined from the target braking pressure, and motor rotational speed was derived from the pressure control error to build up the braking pressure. The position offset of the pump piston resulting from a leak in the hydraulic system is also compensated for using the open-loop speed control by moving the piston backward until it is blocked at the end of stroke position. The performance and stability of the proposed controller were experimentally verified. According to the results, the control algorithm can be utilized as an effective means of degraded control for electro-hydraulic brake systems in the case that a motor position sensor fault occurs.

An Experimental Research of Servo Valve Offset Correction Method of Hydraulic Actuator (유압식 구동장치의 서보밸브 오프셋 보정 방법에 관한 실험적 연구)

  • Ban, Joon Hyeok
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.72-79
    • /
    • 2019
  • Despite the development of electronic components and microprocessors, hydraulic actuators are still being applied in various applications. In some applications, there is a desire to apply a hydraulic actuator with a relatively small position error to the system. Various studies have been conducted to reduce the position error of hydraulic actuators. In this paper, the position error of the hydraulic actuator when the hydraulic oil pressure is supplied is defined as the offset generated by the servo valve, and the method for correcting the servo valve offset has been studied. A method for compensating the servo valve offset was proposed and it was verified through experiments that the position error of the hydraulic actuator was reduced. We also compared the servo valve offset correction method and controller using the PID control and disturbance observer used to reduce the position error of the hydraulic actuator. No-load test and load test were performed to confirm the performance of the servo valve offset correction method. The results of the study were compared with those obtained by using the disturbance observer and PID control.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.