• Title/Summary/Keyword: in-plane and out-of-plane

Search Result 1,847, Processing Time 0.033 seconds

Blast behavior of steel infill panels with various thickness and stiffener arrangement

  • Lotfi, Saeid;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.587-600
    • /
    • 2018
  • Infill panel is the first element of a building subjected to blast loading activating its out-of-plane behavior. If the infill panel does not have enough ductility against the loading, it breaks and gets damaged before load transfer and energy dissipation. As steel infill panel has appropriate ductility before fracture, it can be used as an alternative to typical infill panels under blast loading. Also, it plays a pivotal role in maintaining sensitive main parts against blast loading. Concerning enough ductility of the infill panel out-of-plane behavior, the impact force enters the horizontal diaphragm and is distributed among the lateral elements. This article investigates the behavior of steel infill panels with different thicknesses and stiffeners. In order to precisely study steel infill panels, different ranges of blast loading are used and maximum displacement of steel infill under such various blast loading is studied. In this research, finite element analyses including geometric and material nonlinearities are used for optimization of the steel plate thickness and stiffener arrangement to obtain more efficient design for its better out-of-plane behavior. The results indicate that this type of infill with out-of-plane behavior shows a proper ductility especially in severe blast loadings. In the blasts with high intensity, maximum displacement of infill is more sensitive to change in the thickness of plate rather the change in number of stiffeners such that increasing the number of stiffeners and the plate thickness of infill panel would decrease energy dissipation by 20 and 77% respectively. The ductile behavior of steel infill panels shows that using infill panels with less thickness has more effect on energy dissipation. According to this study, the infill panel with 5 mm thickness works better if the criterion of steel infill panel design is the reduction of transmitted impulse to main structure. For example in steel infill panels with 5 stiffeners and blast loading with the reflected pressure of 375 kPa and duration of 50 milliseconds, the transmitted impulse has decreased from 41206 N.Sec in 20 mm infill to 37898 N.Sec in 5 mm infill panel.

Ecological Changes of Seunghwanglim -Natural Monument No. 93- Wonju Seungnamri (원주 성남리 성황림-천연기념물 제 93호-의 생태적 변화)

  • Kim, Gab-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.6
    • /
    • pp.559-564
    • /
    • 2007
  • This research is aimed at finding out the ecological change of Seunghwanglim through the examination of vegetational change of tree seedlings of old giant trees growing at Seunghwanglim [Seunghwang Forest designated as a Natural Monument No.93] after the installation of protective iron fence. The survey results are as follows: First, as a result of keeping out people by installing a protective iron fence in 1989, soil hardness of the plane forest was greatly improved except the area used as roads. The seedlings of the plane forest, whose damage index is 2,3,4, were found to have the highest 1,202 $individuals/400m^2$, and those of the plane forest, whose damage index is 1, were revealed to have 565 $individuals/400m^2$, and those of the slope forest were found to have 403 $individuals/400m^2$. The number of the young sapling[taller than 2 meters] individuals of the plane forest whose damage index is 1 was found to be the most $48/400m^2$, and that of the plane forest whose damage index is 2, 3, 4- was $31/400m^2$, and that of the slope forest proved to be $14/400m^2$. In the plane forest whose damage index is 2, 3, 4, the saplings of the Ulmus davidiana var. japonica and Acer triflorum are relatively much distributed, and in the plane forest whose damage index is 1, many saplings of the Prunus padus and Styrax obassia, were found to grow and in the slope forest, many saplings of the Acer pictum subsp. mono and Acer pseudo-sieboldianum. were found to grow. Many seedlings of Rubus spp. - R. oldhamii, R. coreanus and R. crataegifolius. - and Akebia quinata were growing vigorously on plane forest, but they might decrease in number with the increasing number of the tree saplings.

Out-of-Plane Elastic Buckling of X-Bracing System with Fixed Ends (고정 지점을 갖는 X-브레이싱의 탄성 면외 좌굴)

  • Moon, Ji-Ho;Yoon, Ky-Yong;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.293-296
    • /
    • 2007
  • This study investigated the out-of-plane elastic buckling load and effective length factor of X-bracing system. The members of X-bracing system which are studied in this paper are rigidly attached to the structure at their end connections, and are pinned or rigidly connected at their point of intersection. The effective length factors are derived for the general case where the tension and compression brace have different material and geometrical properties.

  • PDF

Analytical modeling of thin-walled box T-joints

  • Marur, Prabhakar R.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.3
    • /
    • pp.447-457
    • /
    • 2009
  • A general analytical method for computing the joint stiffness from the sectional properties of the members that form the joint is derived using Vlasov's thin-walled beam theory. The analytical model of box T-joint under out-of-plane loading is investigated and validated using shell finite element results and experimental data. The analytical model of the T-joint is implemented in a beam finite element model using a revolute joint element. The out-of-plane displacement computed using the beam-joint model is compared with the corresponding shell element model. The results show close correlation between the beam revolute joint model and shell element model.

Elastic Analysis of an Unbounded Elastic Solid with an Inclusion Considering Composite Fiber Volume Fraction (섬유 체적분율을 고려한, 단일의 함유체를 포함한 무한고체에서의 탄성해석)

  • Lee, Jung-Ki;Han, Hui-Duck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.89-96
    • /
    • 2007
  • A volume integral equation method (VIEM) is applied for the effective analysis of plane elastostatic problems in unbounded solids containing single isotropic inclusion of two different shapes considering composite fiber volume fraction. Single cylindrical inclusion and single square cylindrical inclusion are considered in the composites with six different fiber volume fractions (0.25, 0.30, 0.35, 0.40, 0.45, 0.50). Using the rule of mixtures, the effective material properties are calculated according to the corresponding composite fiber volume fraction. The analysis of plane elastostatic problems in the unbounded effective material containing single fiber that covers an area corresponding to the composite fiber volume fraction in the bounded matrix material are carried out. Thus, single fiber, matrix material with a finite region, and the unbounded effective material are used in the VIEM models for the plane elastostatic analysis. A detailed analysis of stress field at the interface between the matrix and the inclusion is carried out for single cylindrical or square cylindrical inclusion. Next, the stress field is compared to that at the interface between the matrix and the single inclusion in unbounded isotropic matrix with single isotropic cylindrical or square cylindrical inclusion. This new method can also be applied to general two-dimensional elastodynamic and elastostatic problems with arbitrary shapes and number of inclusions. Through the analysis of plane elastostatic problems, it will be established that this new method is very accurate and effective for solving plane elastic problems in unbounded solids containing inclusions considering composite fiber volume fraction.

An Experimental Study on the Stress Behavior of Coped Stringers in Steel Railway Bridge - I : the Reason Why Crack Occurs (철도교 세로보 절취부에서의 응력거동에 관한 실험적 연구 - I : 균열 발생원인)

  • Li, Guang Ri;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.299-305
    • /
    • 2009
  • In this study, in order to research the causes lead to fatigue crack in the coped stringer of a steel railway bridge, we take the steel railway bridge which actually occurs fatigue crack as a research object and manufacture the full size of crossbeam-stringer and floor system model to perform the experimental test. The results indicates that, the fatigue crack in the top of coped area of stringers is caused by the reciprocal action of the in plane stress in the tip of coped area of web by the negative moment occurred in the end of the stringers. While the fatigue crack in the bottom of coped area of stringers is due to the plane stress caused by the out-plane deformation relative to the bottom of coped area of web of the fixed end in the stringers.

ROENTGENOCEPHALOMETRIC STUDY ON FACIAL HEIGHT AND OCCLUSAL PLANE INCLINATION IN CLASS II MALOCCLUSION GROUP (성인 II 급 환자의 안면 수직고경및 교합평면의 특징에 관한 두부방사선학적 연구)

  • Nahm, Dong-Seok;Jeong, Mi-Hyang
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.255-268
    • /
    • 1998
  • This study was investigated to assess the difference of facial height and occlusal plane inclination between normal occlusion group and class II malocclusion group. The subjects consisted of 50 normal occlusion (male 25, female 25) and 50 class II(male 25, female 25) malocclusion patients. All subjects are adult. lateral cephalogram was taken with standard method traced, and digitized for each subjects. The computerized statiscal analysis was carried out with SPSS program. The results were as follows 1. In class II malocclusion group, variables significant different from normal occlusion group were as follows ; SN-FOP, FH-BOP, MP-BOP, AB-BOP, AB-FOP, Facial plane-BOP, FP-FOP 2. In class II malocclusion group, the posterior facial height -especially posterior lower facial height-was significantly smaller than normal occlusion group.(P<0.05) 3. In class II malocclusion group, the angles between occlusal plane and upper and lower incisor, the angle between upper molar and bisected occlusal plane were significantly larger than those of normal occlusion group. (P<0.05) 4. L1 to Mandibular plane (mm) was a unique factor of occlusal plane position that showed significant difference in class II malocclusion group. 5. The correlation between overbite and occlusal plane inclination existed in class II malocclusion group, but the correlation didn't exist in normal occlusion group.

  • PDF

Research on stress distributions around welds of three-planar tubular Y-joints under out-of-plane bending moment

  • Shiliu Bao;Wenhua Wang;Jikai Zhou;Xin Li
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.181-196
    • /
    • 2023
  • Marine structures including offshore wind turbines (OWTs) always work under cyclic loads, which arouses much attention on the fatigue design. The tripod substructure is one of the typical foundation forms for fixed OWTs. The three-planar tubular Y-joint (3Y joint) is one of the important components in fatigue design as it is most likely to have cracks. With the existence of the multiplanar interaction effect, calculating the hot spot stress (HSS) of 3Y joints is complicated. To assist with fatigue design, the distributions of stress concentration factor (SCF) and multiplanar interaction factor (MIF) along weld toe curves induced by the out-of-plane bending moment are explored in this study. An FE analysis method was first developed and verified against experimental results. This method was applied to build a numerical database including 1920 FE models covering common ranges of geometric parameters. A parametric study has been carried out to reveal the distribution patterns of SCF and MIF. After multidimensional nonlinear fittings, SCF and MIF distribution formulas have been proposed. Accuracy and reliability checking prove that the proposed formulas are suitable for calculating the HSS of 3Y joints.

A Study on the Damage of CFRP Laminated Composites Under Out-of-Plane Load (횡방향 하중을 받는 CFRF 적층복합재의 내부손상에 관한 연구)

  • Kim, Moon-Saeng;Park, Seung-Bum;Oh, Deug-Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.11
    • /
    • pp.98-109
    • /
    • 1995
  • An investigation was performed to study the inner damage of laminated composite plates subjected to out-of-plane load. During the investigation, inpact velocity and equivalent static load relationship was derived. Reddy's higher-order shear deformation theory(HSDT) and Hashin's failure criteria were used to determine inner stresses and damaged area. And impact testing was carried out on laminated composite plates by air gun type impact testing machine. The CFRP specimens were composed of [ .+-. 45 .deg. ]$_{4}$and [ .+-. 45 .deg. /0 .deg. /90 .deg. ]$_{2}$ stacking sequences with 0.75$^{t}$ * 26$^{w}$ * 100$^{l}$ (mm) dimension. After impact testing. As a result, a relationship holds between damaged area and impact energy, and a matrix cracking was caused by the interlaminar shear stress in the middle ply and was caused by the inplane transverse stress in the bottom ply.

  • PDF

Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure

  • Karantoni, Fillitsa;Tsionis, Georgios;Lyrantzaki, Foteini;Fardis, Michael N.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.689-713
    • /
    • 2014
  • The seismic vulnerability of stone masonry buildings is studied on the basis of their fragility curves. In order to account for out-of-plane failure modes, normally disregarded in past studies, linear static Finite Element analysis in 3D of prototype regular buildings is performed using a nonlinear biaxial failure criterion for masonry. More than 1100 analyses are carried out, so as to cover the practical range of the most important parameters, namely the number of storeys, percentage of side length in exterior walls taken up by openings, wall thickness, plan dimensions and number of interior walls, type of floor and pier height-to-length ratio. Results are presented in the form of damage and fragility curves. The fragility curves correspond well to the damage observed in masonry buildings after strong earthquakes and are in good agreement with other fragility curves in the literature. They confirm what is already known, namely that buildings with stiff floors or higher percentage of load-bearing walls are less vulnerable, and that large openings, taller storeys, larger number of storeys, higher wall slenderness and higher ratio of clear height to horizontal length of walls increase the vulnerability, but show also by how much.