• Title/Summary/Keyword: in-Phase

Search Result 41,837, Processing Time 0.064 seconds

Air-Water Two-Phase Flow Performances of Centrifugal Pump with Movable Bladed Impeller and Effects of Installing Diffuser Vanes

  • Sato, Shinji;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • It's known that pump head of centrifugal impeller with lager blade outlet angle is kept higher in air-water two phase flow condition, though the efficiency in water single phase flow condition is inferior. In the present study, a centrifugal impeller with variable blade outlet angles, that has higher efficiencies in both water single phase flow and air-water two phase flow conditions, is proposed. And the performances of the centrifugal impeller with variable blade outlet angles were experimentally investigated in both flow conditions of single and two-phase. In addition, effects of installing diffuser vanes on the performances of centrifugal pump with movable bladed impeller were also examined. The results are as follows: (1) The movable bladed impeller that proposed in this study is effective for higher efficiency in both water single phase and air-water two phase flow conditions. (2) When diffuser vanes are installed, the efficiency of movable bladed impeller decreases particularly at large water flow rate in water single-phase flow condition; (3) The performances of movable bladed impeller are improved by installing of diffuser vanes in air-water two-phase flow condition at relatively small water rate. The improvement by installing of diffuser vanes however disappears at large water flow rate.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

A Study on the Precipitation of σ Phase in Super Duplex Stainless Steel (슈퍼 2상 스테인리스강의 σ상 석출에 관한 연구)

  • Gang, Chang-Yong;Klm, Ick-Soo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.286-291
    • /
    • 2001
  • This study was carried out to investigate the influence of ${\sigma}$ phase on the microstructure and mechanical properties in super duplex stainless steel. The precipitation of ${\sigma}$ phase during isothermal heat treatment showed the type S curves with a certain incubation period. The precipitation of ${\sigma}$ phase was precipitated at ferrite phase and interface of ferrite and austenite. Under the state of isothermal transformation, the precipitation of ${\sigma}$ phase was stimulated by applied stress. With increasing of volume fraction of precipitated ${\sigma}$ phase, tensile strength was increased and elongation was decreased with linear relationship, while in case of precipitated ${\sigma}$ phase was 5% over, impact value was rapidly decreased.

  • PDF

A Boundary Diffusion Creep Model for the Plastic Deformation of Grain Boundary Phase of Nanocrystalline Materials (나노재료 입계상의 소성변형에 대한 입계확산크립 모델)

  • 김형섭;오승탁;이재성
    • Transactions of Materials Processing
    • /
    • v.10 no.5
    • /
    • pp.383-388
    • /
    • 2001
  • In describing the plastic deformation behaviour of ultrafine-grained materials, a phase mixture model in which a polycrystalline material is regarded as a mixture of a crystalline phase and a grain boundary phase has been successful. The deformation mechanism for the grain boundary phase, which is necessary for applying the phase mixture model to polycrystalline materials, is modelled as a diffusional flow of matter along the grain boundary. A constitutive equation for the boundary diffusion creep of the boundary phase was proposed, in which the strain rate is proportional to (stress/grain siz $e^{2}$). The upper limit of the stress of the boundary phase was set to equal to the strength to the amorphous phase. The proposed model can explain the strain rate and grain size dependence of the strength of the grain boundary phase. Successful applications of the model compared with published experimental data are described.

  • PDF

Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL (분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

Selection of Voltage Vectors in Three-Level Five-Phase Direct Torque Control for Performance Improvement

  • Tatte, Yogesh N.;Aware, Mohan V.
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2162-2172
    • /
    • 2016
  • This paper presents a Direct Torque Control (DTC) strategy for the five-phase induction motor driven by a three-level five-phase inverter in order to improve the performance of the five-phase induction motor. In the proposed DTC technique, only 22 voltage vectors out of 243 available voltage vectors in a three-level five-phase inverter are selected and are divided in 10 sectors each with a width of $36^{\circ}$. The four different DTC combinations (DTC-I, II, III and IV) for a three-level five-phase induction motor drive are investigated for improving the performance of five-phase induction motor. All four of the DTC strategies utilize a combination of the same large and zero voltage vectors, but with different medium voltage vectors. Out of these four techniques, DTC-II gives the best performance when compared to the others. This DTC-II technique is analyzed in detail for improvements in the performance of five-phase induction motor in terms of torque ripple, x-y stator flux and Total Harmonics Distortion (THD) of the stator phase current when compared to its two-level counterparts. To verify the effectiveness of the proposed three-level five-phase DTC control strategy, a DSP based experimental system is build. Simulation and experimental results are provided in order to validate the proposed DTC technique.

Minimization of Torque-Ripple in Switched Reluctance Motors Over Wide Speed Range

  • Dowlatshahi, Milad;Saghaiannejad, Seyed Morteza;Ahn, Jin-Woo;Moallem, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.478-488
    • /
    • 2014
  • Torque pulsation mechanism and highly nonlinear magnetic characterization of switched reluctance motors(SRM) lead to unfavorable torque ripple and limit the variety of applications in industry. In this paper, a modification method proposed for torque ripple minimization of SRM based on conventional torque sharing functions(TSF) to improve maximum speed of torque ripple-free operation considering converter limitations. Due to increasing phase inductance in outgoing phase during the commutation region, reference current tracking can be deteriorated especially when the speed increased. Moreover, phase torque production in incoming phase may not be reached to the reference value near the turn-on angle in which the incremental inductance would be dramatically decreased. Torque error for outgoing phase can cause increasing the resultant motor torque while it would be negative for incoming phase and yields reducing the motor torque. In this paper, a modification method is proposed in which phase torque tracking error for each phase under the commutation added to the other phase so that the resultant torque remained in constant level. This yields to extend constant torque region and reduce peak phase current when the speed increased. Simulation and experimental results for four phase 4 KW, 8/6 SRM validate the effectiveness of the proposed scheme.

Nurses단 Role Models, Perceptions Toward Occupation, Self-Actualization Value and the Phases of Socialization Process (임상간호원의 사회화과정단계에 있어서의 역할모델, 직업에 대한 지각향성 및 자아실현성간의 관계)

  • 한윤복;강윤숙
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.1
    • /
    • pp.24-32
    • /
    • 1987
  • This study was designed to investigate the changes of nurses' role model, perceptions toward occupation, and self actualization value in terms of the phases of socialization process. Two hundred and sixty nine nurses working in clinical settings were randomly selected from 15 general hospitals despersed over Seoul and Kyungki province. Data were gathered by the standardized Perceptual Orientation Test, the Self-actualization Test, and Questionnaires on role models and phases of socialization process developed by the investigators from October 1985 to March 1986. The data were analysed by ANOVA and Pearson's Correlation Coefficient. The results were as follows: 1. The average time period required for the shift of phases of socialization process were; phase Ⅰ, role adjustment, took average 10 months of employment: Phase Ⅱ, interpersonal adjustment, 12 months: and Phase Ⅲ, role conflict, 15 months respectively. Conflict resolution, phase Ⅳ, began to take place 18 months of employment; and shifted to phase V, internalization and self-actualization at 25 months of employment. 2. Throughout 5 consecutive phase, the number of immediate superior nurse model was dominantly the highest among the role models. The number of head nurse role model increased at phase Ⅱ, phase Ⅲ, and phase Ⅳ. Respondents with school model in phase I tended to transfer to work model at phase Ⅱ. 3. The perceptions toward occupation were not significantly influenced by the Phases of socialization process. 4. The score of self-actualization value was not significantly influenced by the phases of socialization process. 5. In regard to perceptions toward occupation, nursing director model group showed significantly lower score in phase I (p<.01). 6. The comparison of self-actualization value between the 5 phases revealed significant difference in phase I: in particular among respondents with school model at p<.05. To conclude: 1. The phase Ⅲ of socialization process is the period of role conflict which occur at 15 months of employment, an6 conflict resolution, phase Ⅳ, begins at 18 months of employment on the average in clinical settings. 2. The immediate superior nurse and the head nurse are important role models for nurses all through their socialization process.

  • PDF

Phase Relations in Colon Classification (콜론분류법에서의 상(相)관계)

  • Kim, T.S.
    • Journal of the Korean Society for information Management
    • /
    • v.4 no.2
    • /
    • pp.47-61
    • /
    • 1987
  • Main advantages of an analytico-synthetic scheme are its flexibility and its ability to cope with new subjects as they arise. Accordingly the synthetic scheme can keep pace with changes in knowledge more easily than an enumerative scheme because new subjects often merely involve fresh combinations of basic unit parts already listed. The findings of the study are as follows: 1. Each part of the components of a complex subject is called phase in CC and we are able to obtain three levels of phase relations such as intra-facet phase relation, intra-array - phase relation and inter-subject phase relation. 2. Different digits are used in CC to represent different varieties of phase relation in each levels. 3. The mode of phase relation may be taken to indicate the strength of bond between the phase and may form a new main subject. 4. In the rules and grammar of the phase relation the extension of two-phase subject is possible up to any extent theoritically. 5. Phase relation in DDC was introduced in the 18th edition, but there was no provision for the kind and the level of phase relation. 6. Colon(:) of the UDC is used to represent phase relation but there was also no provision for the kind and the level of phase relation.

  • PDF