• Title/Summary/Keyword: in vivo imaging

Search Result 387, Processing Time 0.023 seconds

Synthesis of 125I-Labeled Hyaluronic Acid (방사성 히알루론산 합성)

  • Ma, So-Young;Lee, Dong-Eun;Park, Sang Hyun
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.77-81
    • /
    • 2014
  • Hyaluronic acid is a disaccharide polymer that consists of glucuronic acid and N-acetylglucosamine, and is a glycosaminoglycan. It is widely distributed in animal connective tissue, coexisting with chondroitin sulfate. It forms viscous secretions or gel by bonding to protein in the body, and thus maintains and lubricates tissue structures. In addition, its antibiotic properties are applied to cosmetics and pharmaceuticals. Therefore, it has recently been an object of great interest at cosmetic and pharmaceutical companies. $^{125}I$ has a longer half-life (59.4 days) than many other radioisotopes, and is therefore useful to long-term studies. In this study, a facile and efficient procedure for the synthesis of $^{125}I$-labeled hyaluronic acid has been designed for in vivo imaging and pharmacokinetic studies of hyaluronic acid, which are required for the development of new drugs.

High-Speed SD-OCT for Ultra Wide-field Human Retinal Three Dimensions Imaging using GPU (병렬처리 그래픽 기술 기반의 Spectral Domain-Optical Coherence Tomography를 이용한 3차원 광 대역 망막 촬영)

  • Park, Kibeom;Cho, Nam Hyun;Wijesinghe, Ruchire Eranga Henry;Kim, Jeehyun
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be $1024{\times}2000{\times}300$ pixels which took 9 seconds for visualization.

Gold Nanoparticles Coated with Gd-Chelate as a Potential CT/MRI Bimodal Contrast Agent

  • Sk Md., Nasiruzzaman;Kim, Hee-Kyung;Park, Ji-Ae;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1177-1181
    • /
    • 2010
  • The synthesis and characterization of gold nanoparticles coated by Gd-chelate (GdL@Au) is described, where L is a conjugate of DTPA (DTPA = diethylenetriamine-N,N,N',N",N"-pentaacetic acid) and 4-aminothiophenol. These particles are obtained by the replacement of citrate from the gold nanoparticle surfaces with gadolinium chelate (GdL). The average size of GdL@Au is 12 nm with a loading of GdL reaching up to $1.4{\times}10^3$ per particles, and they demonstrate very high r1 relaxivity (${\sim}10^4mM^{-1}s^{-1}$) and the r1 relaxivity per [Gd] is as high as $10mM^{-1}s{-1}$. Here, we also describe the use of bimodality of this contrast agent (CA) as a highly efficient CT contrast agent based on gold nanoparticles (GNPs) that overcome the limitations of iodine based contrast agent. The MTT assay performed on this CAs reveals the cytotoxicity as low as that for Omniscan$^{(R)}$ in the concentration range required to obtain intensity enhancement in the in vivo MRI study.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF

Localization of Bilateral Hemisphere Lesion Using Combined Transcranial Magnetic Stimulation and Diffusion Tensor Imaging: Report of Two Cases (경두개 자기자극과 확산텐서 신경섬유로 검사를 통한 대뇌 병변의 국소화: 증례보고)

  • Lee, Hyung Nam;Oh, Young-Bin;Kim, Gi-Wook;Won, Yu Hui;Ko, Myoung-Hwan;Seo, Jeong-Hwan;Park, Sung-Hee
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.106-111
    • /
    • 2018
  • Transcranial magnetic stimulation (TMS) has been a gold standard for investigating central motor pathways in humans. Diffusion tensor imaging with fiber tractography (DTI FT) is known for its usefulness in detecting white matter lesion in vivo. We investigated the clinical usefulness of elucidating the integrity and continuity of corticospinal tract (CST) by combined use of TMS and DTI FT in this study. We report two cases who have presented with left hemiparesis and evaluated by both TMS and DTI FT; 10-year-old boy with Mitochondrial Encephalomyopathy with Lactic Acidosis and Stroke-like episode syndrome and 20-year-old woman with traumatic brain injury. Combined use of TMS and DTI FT successfully led to localize the brain lesion that might cause motor impairment in patients with abnormal signal intensities in MRI. The results of this study suggest that TMS and DTI FT might provide the detailed information between function and anatomy of the CST, complementarily.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

In Vivo Image and Biodistribution of $^{123}I$-15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP) in Liposarcoma Bearing Nude Mice (지방육종형성 동물모델에서 $^{123}I$-15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP)의 생체분포와 생체영상)

  • Lee, Tae-Sup;Suh, Yong-Sup;Choi, Chang-Woon;Woo, Kwang-Sun;Chung, Wee-Sup;Lim, Soo-Jung;Lim, Sang-Moo;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.5
    • /
    • pp.324-333
    • /
    • 2001
  • Purpose: $^{123}I$-labeled fatty acids have been used in the evaluation of regional myocardial energy metabolism. This study aimed to evaluate the usefulness of $^{123}I$-BMIPP as a liposarcoma-imaging agent. Materials and Methods: We compared in vitro uptakes between liposarcoma(SW872) and glioma(9L) cell lines, and examined biodistribution and in vivo images of $^{123}I$-BMIPP in liposarcoma-bearing nude mice. Cold-BMIPP was labeled with $^{123}I\;using\;Cu^{2+}$ as catalyst. After purification by Sep-pak, radiochemical purity was determined by TLC. We compared cellular uptake between glioma and liposarcoma after incubation of 5, 10, 15, 30, 60, 120, and 180 mins with culture medium containing $^{123}I$-BMIPP. The difference in biodistribution was determined between non-feeding (water only) group for 18 hr and feeding group in normal mice (n=6/group) at 0.5, 2, and 24 hr. In liposarcoma-hearing nude mice model, liposarcoma, SW872, ceil lines were injected subcutaneously into the felt thigh of nude mice. The biodistribution of $^{123}I$-BMIPP was evaluated at 0.5, 2, and 24 hr (n:5 / group) and in vivo Image of $^{123}I$-BMIPP was obtained with gamma camera at 2 and 24 hr in liposarcoma-hearing nude mice. Results: Radiolabeling yield and radiochemical purity were 95% and above 99%, respectively. SW872 cell line showed more increased uptake than 9L with 1.5 times at 180 mins. The clearance of $^{123}I$-BMIPP in various tissues was more delayed in the non-feeding group than in the feeding group, especially at delayed time (24 hr) in normal mice, and the major excreting organ was the gastrointestinal tract. In liposarcoma-bearing nude mice, tumor/blood ratio of $^{123}I$-BMIPP was 0.94, 0.75, and 1.38 and tumor/muscle ratio was 0.66, 1.53, and 1.11 at 0.5, 2, and 24hr, respectively. $^{123}I$-BMIPP was selectively localized in liposarcoma at 24 hr image. Conclusions: These results suggest that $^{123}I$-BMIPP can be used as a liposarcoma-imaging agent.

  • PDF

Effects of Pinacidil, a Potassium-Channel Opener, on Biodistribution of Thallium-201 in Tumor-Bearing Mice ($K^+$ 통로개방제 Pinacidil이 종양이식 생쥐에서 Tl-201의 체내분포에 미치는 영향)

  • Lee, Jae-Tae;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Ahn, Byeong-Cheol;Jun, Soo-Han;Lee, Kyu-Bo;Ha, Jeoung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.303-311
    • /
    • 2000
  • Purpose: Thallium behaves similarly to potassium in vivo. Potassium channel opener (K-opener) opens ATP-sensitive $K^+$-channel located at cell membrane, resulting in potassium efflux from cytosol. We have previously reported that K-opener can alter biokinetics of Tl-201 in cultured cells and in vivo. Malignant tumor cells have high Na-K ATPase activity due to increased metabolic activities and dedifferentiation, and differential delineation of malignant tumor can be possible with Tl-201 imaging. K-opener may affect tumoral uptake of Tl-201 in vivo. To investigate the effects of pinacidil (one of the potent K-openers) on the localization of the tumor with Tl-201 chloride, we evaluated the changes in biodistribution of Tl-201 with pinacidil treatment in tumor-bearing mice. Materials and Methods: Baltic mice received subcutaneous implantation of murine breast cancer cells in the thigh and were used for biodistribution study 3 weeks later. $100{\mu}g$ of pinacidil dissolved in $200{\mu}l$ DMSO/PBS solution was injected intravenously via tail vein at 10 min after 185 KBq ($5{\mu}Ci$) Tl-201 injection. Percentage organ uptake and whole body retention ratio of Tl-201 were measured at various periods after injection, and values were compared between control and pinacidil-treated mice. Results: Pinacidil treatment resulted in mild decrease in blood levels of Tl-201, but renal uptakes were markedly decreased at 30-min, 1- and 2-hour, compared to control group. Hepatic, intestinal and muscular uptake were not different. Absolute percentage uptake and tumor to blood ratios of Tl-201 were lower in pinacidil treated mice than in the control group at all time points measured. Whole body retention ratio of Tl-201 was lower in pinacidil treated mice ($58{\pm}4%$ ), than in the control group ($67{\pm}3%$) at 24 hours after with injection of $100{\mu}g$ pinacidil. Conclusion: K-opener did not enhance, but rather decreased absolute tumoral uptake and tumor-to-blood ratios of Tl-201. Decreased whole body retention ratio and renal uptake were observed with pinacidil treatment in tumor-bearing mice.

  • PDF

Dual Component Analysis for In Vivo T2* Decay of Hyperpolarized 13C Metabolites

  • Joe, Eunhae;Lee, Joonsung;Lee, Hansol;Yang, Seungwook;Choi, Young-Suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: To investigate the exchange and redistribution of hyperpolarized $^{13}C$ metabolites between different pools by temporally analyzing the relative fraction of dual $T_2{^*}$ components of hyperpolarized $^{13}C$ metabolites. Materials and Methods: A dual exponential decay analysis of $T_2{^*}$ is performed for [1-$^{13}C$] pyruvate and [1-$^{13}C$] lactate using nonspatially resolved dynamic $^{13}C$ MR spectroscopy from mice brains with tumors (n = 3) and without (n = 4) tumors. The values of shorter and longer $T_2{^*}$ components are explored when fitted from averaged spectrum and temporal variations of their fractions. Results: The $T_2{^*}$ values were not significantly different between the tumor and control groups, but the fraction of longer $T_2{^*}$ [1-$^{13}C$] lactate components was more than 10% in the tumor group over that of the controls (P < 0.1). The fraction of shorter $T_2{^*}$ components of [1-$^{13}C$] pyruvate showed an increasing tendency while that of the [1-$^{13}C$] lactate was decreasing over time. The slopes of the changing fraction were steeper for the tumor group than the controls, especially for lactate (P < 0.01). In both pyruvate and lactate, the fraction of the shorter $T_2{^*}$ component was always greater than the longer $T_2{^*}$ component over time. Conclusion: The exchange and redistribution of pyruvate and lactate between different pools was investigated by dual component analysis of the free induction decay signal from hyperpolarized $^{13}C$ experiments. Tumor and control groups showed differences in their fractions rather than the values of longer and shorter $T_2{^*}$ components. Fraction changing dynamics may provide an aspect for extravasation and membrane transport of pyruvate and lactate, and will be useful to determine the appropriate time window for acquisition of hyperpolarized $^{13}C$ images.

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.