• Title/Summary/Keyword: in vivo imaging

Search Result 388, Processing Time 0.023 seconds

A Study on the Fluorescence Characteristics of Dye-doped Silica Nanoparticles for Integrated Bio Imaging (융합 바이오 이미징을 위한 염료 도핑 된 실리카 나노입자의 형광 특성에 관한 연구)

  • Kim, Ki-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.45-50
    • /
    • 2018
  • The functional nanomaterials of fluorescent dye-doped silica nanoparticles(NPs) are applied to bio applications such as bio-labeling of DNA micro-array, and bio-imaging. Organic dye-doped fluorescent silica NPs exhibit excellent bio-compatibility, non-toxic, and highly hydrophilic properties. In this study, organic fluorescent dyes were dissolved in ethanol, and deionized(DI) water. Organic fluorescent dyes were physically adsorbed to silica NPs and chemically doped to silica NPs. The fluorescence characteristics(FLC) was investigated by UV lamp irradiation of 365 nm wavelength. As results, the FLC of dye-doped silica NPs exhibits better than dye-adsorbed silica NPs and the FLC was improved with the increase of concentration of doped-dyes. The fluorescent organic dyes were well dissolved in ethanol than DI water. The photostability of dye-doped silica NPs was superior than pure fluorescent organic dye. The FLC of optimized dye-doped silica NPs would be applied to agent of non-invasive fluorescence bio-imaging in live cell and in vivo.

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation (뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성)

  • Kim, Min Jung;Lee, Sang-Yeol;Lee, Hui Joong;Lee, Taekwan;Chang, Yongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.

Diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography images of a non-displaced fracture of ovine mandibular bone

  • Farzane Ostovarrad;Sadra Masali Markiyeh;Zahra Dalili Kajan
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.375-381
    • /
    • 2023
  • Purpose: This study assessed the diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography (CBCT) images of non-displaced ovine mandibular fractures. Materials and Methods: In this ex vivo study, non-displaced fractures were artificially created in 10 ovine mandibles (20 hemi-mandibles) using a hammer. The control group comprised 8 hemi-mandibles. The non-displaced fracture lines were oblique or vertical, <0.5 mm wide, 10-20 mm long, and only in the buccal or lingual cortex. Fracture lines in the ramus and posterior mandible were created to be at the interface or borders of the 2 stitched images. CBCT images were obtained from the specimens with an 80 mm×80 mm field of view before and after fracture induction. OnDemand software (Cybermed, Seoul, Korea) was used for stitching the CBCT images. Four observers evaluated 56 (28 stitched and 28 non-stitched) images to detect fracture lines. The diagnostic performance of stitched and non-stitched images was assessed by calculating the area under the receiver operating characteristic curve (AUC). Sensitivity and specificity values were also calculated (alpha=0.05). Results: The AUC was calculated to be 0.862 and 0.825 for the stitched and non-stitched images, respectively (P=0.747). The sensitivity and specificity were 90% and 75% for the non-stitched images and 85% and 87% for the stitched images, respectively. The inter-observer reliability was shown by a Fleiss kappa coefficient of 0.79, indicating good agreement. Conclusion: No significant difference was found in the diagnostic performance of stitched and non-stitched cross-sectional CBCT images of non-displaced fractures of the ovine mandible.

New Measurement of Whitening Effects by Using Confocal Scanning Laser Microscope (CSLM) (Confocal Scanning Laser Microscope (CSLM)을 이용한 신규 미백 효과 측정 연구)

  • Kim, Myong Ki;Cho, Seok-Cheol;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.279-285
    • /
    • 2015
  • Hyperpigmentation on face is a highly anxiety-producing symptom, especially for women from the aspect of beauty. Pigmentation of the skin is related to the amount of melanin that provides protection against UV radiation. In vivo reflectance confocal microscopy is a non-invasive imaging tool allowing visualization of the skin without tissue alteration, by placing a microscopy directly on the living skin. The aim of this study was to develop the new evaluation method of whitening effects using in vivo reflectance confocal microscopy and to validate other instruments for measuring skin colors, and UV-induced hyperpigmentation was elicited on the inside skin of the forearm. It suggested that the new method for whitening effects using the confocal microscopy was useful to evaluate the de-pigmentation products and to easy for understanding to customers.

Preoperative Evaluation of the Facial Artery Using Facial Angio Computed Tomography (전산화단층촬영 혈관조영술을 이용한 얼굴동맥의 수술 전 평가)

  • Kim, Joo-Hak;Kang, Nak-Heon;Lee, In-Ho;Seo, Young-Joon;Yang, Ho-Jik;Song, Seung-Han;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.719-724
    • /
    • 2011
  • Purpose: Previous studies of the facial artery have shown significant anatomical variability in this region. The vascular anatomy of the region is considered unreliable in predicting the ideal pedicle. Preoperative imaging has been suggested as a means of improving preoperative awareness, with Doppler ultrasound as useful tools. Multi-detector row angiographic computed tomography (angio CT) is a significant improvement, providing noninvasive operator-independent details of the vascular anatomy. This tool was used to perform an $in$ $vivo$ anatomical study of the facial artery, demonstrating the usefulness of facial angio CT in planning the facial reconstruction. Methods: Eleven consecutive patients underwent facial angio CT of the facial vasculature with the anatomical details of the facial artery assessed. Results: Facial angio CT could demonstrate the size and course of the facial vasculature, particularly the facial artery. Conclusion: The vascular anatomy of the facial artery is highly variable, and thus there is a role for preoperative imaging. Facial angio CT can demonstrate cases where there is an aberrant or non-preferred anatomy, or select the method of a facial reconstruction.

Folate Receptor-Specific Positron Emission Tomography Imaging with Folic Acid-Conjugated Tissue Inhibitor of Metalloproteinase-2

  • Kim, Sung-Min;Choi, Naeun;Hwang, Seungkyun;Yim, Min Su;Lee, Jung-Sik;Lee, Sang-Mok;Cho, Gyunggoo;Ryu, Eun Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3243-3248
    • /
    • 2013
  • The tissue inhibitor of metalloproteinase-2 (TIMP-2) inhibits matrix metalloproteinases activity and modulates cellular proliferation and apoptosis. The human serum albumin-TIMP-2 with folic acid conjugate (termed HT2-folate) was synthesized to promote uptake through folate receptors (FRs), and a corresponding radio-labeled compound was prepared for tumor diagnosis by positron emission tomography (PET). $^{68}Ga$-NOTA-HT2-folate was synthesized from $^{68}Ga$ and the NOTA chelator with HT2-folate. The fusion protein was identified using MALDI-TOF mass spectrometry. The radioligand was prepared with a high radiochemical yield. Cell-surface association of $^{68}Ga$-NOTA-HT2-folate significantly increased over time in FR-positive tumor cells. In animal PET and biodistribution studies, tumor uptake was very high as early as 1 h after radioligand injection. Folate conjugation enhanced the selective receptor-targeting efficacy of HT2 in FRexpressing tumors, and its radioligand will be useful as an in vitro tool and for in vivo tumor diagnosis by PET imaging.

Display-Pixel-Based Focusing Method for Ultrasound Imaging (의료 초음파 영상을 위한 화소단위 집속기법)

  • 황재섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.419-431
    • /
    • 2000
  • In this paper, a new beamforming technique is proposed, which can completely eliminate all the artifacts caused by digital scan converter. In the proposed method, named display-pixel-based focusing(DPBF) by the authors, ultrasound waves are focused directly at the display pixels instead of sampling points on the polar coordinate. Consequently. the DPBF system does not require the digital scan converter. To verify the proposed method, we modified a commercial scanner and performed experiments with a 3.5 MHz convex array and a 7.5 MHz linear array. We also defined and measured ICRA/B(Image Coarseness Ratio) to compare the image quality quantitatively. The experimental results with in vivo and in vitro data show that the proposed method improves the ICRA/B considerably, resulting in much smoother and finer images.

  • PDF

Development of an RNA Expression Platform Controlled by Viral Internal Ribosome Entry Sites

  • Ko, Hae Li;Park, Hyo-Jung;Kim, Jihye;Kim, Ha;Youn, Hyewon;Nam, Jae-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.127-140
    • /
    • 2019
  • Since 1990, many nucleic acid expression platforms consisting of DNA or RNA have been developed. However, although RNA expression platforms have been relatively neglected, several such platforms capped at the 5' end of RNA by an anti-reverse cap analog have now been developed. At the same time, the capping reaction is a bottleneck in the production of such platforms, with high cost and low efficiency. Here, we investigated several viral and eukaryotic internal ribosome entry sites (IRESs) to develop an optimal RNA expression platform, because IRES-dependent translation does not require a capping step. RNA expression platforms constructed with IRESs from the 5' untranslated regions of the encephalomyocarditis virus (EMCV) and the intergenic region of the cricket paralysis virus (CrPV) showed sufficient expression efficiency compared with cap-dependent RNA expression platforms. However, eukaryotic IRESs exhibited a lower viral IRES expression efficiency. Interestingly, the addition of a poly(A) sequence to the 5' end of the coxsackievirus B3 (CVB3) IRES (pMA-CVB3) increased the expression level compared with the CVB3 IRES without poly(A) (pCVB3). Therefore, we developed two multiexpression platforms (termed pMA-CVB3-EMCV and pCrPV-EMCV) by combining the IRESs of CVB3, CrPV, and EMCV in a single-RNA backbone. The pMA-CVB3-EMCV-derived RNA platform showed the highest expression level. Moreover, it clearly exhibited expression in mouse muscles in vivo. These RNA expression platforms prepared using viral IRESs will be useful in developing potential RNA-based prophylactic or therapeutic vaccines, because they have better expression efficiency and do not need a capping step.

Development & Assessment of Alkyl Chain Modified Aptamers as Potential PET Radiotracers for Lymphoma Diagnosis

  • Ji Woong Lee;Un Chol Shin;Seok u Bae;Ji Yoon Kim;Hae joon Cho;Ji Ae Park;Kyo Chul Lee;Jung Young Kim;Suhng Wook Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • The Td05 and Sgc8c, DNA-based aptamers, are well-known to target internalized surface markers (IGHM and PTK7) of Burkitt's lymphoma and acute lymphoblastic leukemia (ALL). Thus, Td05 and Sgc8c labeled with metallic radioisotope 64Cu can be evaluated as potential diagnostic PET imaging agents. In this study, we modified the carbon chain length of the last adenosine of aptamer (n = 3, 6, 12) to increase tumor cell uptake and select the best candidate among six types of aptamer analogues and one adenosine of aptamer. After labeling of 64Cu, [64Cu]Cu-DOTA-aptamer analogues were evaluated in vitro studies (serum stability, Log P values, cell uptake, biodistribution). Then, we evaluate in vivo PET imaging study for two candidates (64Cu-DOTA-C12-Sgc8c, 64Cu-DOTA-C6-Td05). PET images clearly visualize tumors at 24 h post-injection rather than at an early time point and the tumor-to-background ratio also increases at the delay time point. 64Cu-DOTA-C12-Sgc8c and 64Cu-DOTA-C6-Td05 could be used as potential radiotracers for lymphoma.