• Title/Summary/Keyword: in vivo측정

Search Result 627, Processing Time 0.02 seconds

천연물 항암제의 유도체 개발

  • 심영기
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.212-212
    • /
    • 1994
  • 본 연구소에서 분리하여 항암활성을 측정한바 있는 Sesquiterpene lactone계열의 KR-53170이 in vitro에 비해 in vivo에서 상대적으로 낮은 효력을 보이는데 착안 그 유도체들을 합성함으로써 in vivo stability 및 efficacy를 개선하고자 하였다. 합성된 물질의 in vivo activity는 human tumor cell중에서 A549(폐암), SK-OV-3(난소암1, SK-MEL-2(피부암), XF-498(중추신경계암), HCT-15(직장암)의 5개 암세포를 이용하여 ED$_{50}$($\mu\textrm{g}$/ml )를 측정하였으며 대조물질로는 KR-53170과 Cisplatin이 사용되었다. 그 결과 HR-53170의 terminal methyl ketone이 carboxylic acid로 변환된 CW-251001과 이것의 methyl ester인 CW-251002, ethyl ester인 CW-251003, 그리고 morpheline과 수용성으로 N-methylpiperazine, N-methyl-N'-aminopiperazine, 4-Piperidinopiperidine을 결합시켜서 합성한 CW-251011, CW-251012, CW-251013, CW-251014가 in vitro에서 어느 정도 활성을 유지하였다. 특히 이들중 CW-251001, CW-251012, CW-251013, CW-2s1014는 물에 대한 용해도가 상당히 개선되어 in vivo 활성검색을 위한 후보물질로 고려되었다. 하지만 이들중 CW-251001은 in vivo에서 낮은 농도에서는 활성이 거의 없었으며 놓은 농도에서는 독성을 나타내었다.

  • PDF

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF

Chest Wall Thickness Measurement of the LLNL Phantom for Ce Detectors (Ce 검출기를위한 LLNL 팬텀의가슴벽두께측정)

  • Lee, Tae-Young;Lee, Jong-Il;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.3-9
    • /
    • 2000
  • The Korea Atomic Energy Research Institute acquired the Lawrence Livermore National Laboratory phantom for calibration of germanium detectors used for in vivo measurement of radionuclides deposited in human lungs. The manufacturer inscribed concentric circles as a phoswich detector positioning guides on the phantom's torso plate and its overlay plates, and provided the effective thickness of the chest wall for each plate measured at locations over the circles. However, since the germanium detectors are of different sizes, the areas considered for phoswich detectors were no. longer applicable for the locations of the germanium detectors on the phantom. Therefore, we re-evaluated the effective thickness of the phantom to determine if the manufacturer' s data are valid for germanium detectors in use for in vivo lung counting or if new values must be implemented. Differences no more than 3% in effective thickness were found between the germanium detector regions to be used at the Korea Atomic Energy Research Institute and the phoswich detector regions prescribed by the manufacturer.

  • PDF

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

LiF TLD in TLD Holder for In Vivo Dosimetry (생체 내 선량측정을 위한, TLD홀더에 넣은 LiF TLD)

  • Kim Sookil;Loh John J.K.;Min Byungnim
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.293-299
    • /
    • 2001
  • Prupose : LiF TLD has a problem to be used in vivo dosimetry because of the toxic property of LiF. The aim of this study is to develop new dosimeter with LiF TLD to be used in vivo dosimetry. Materials and methods : We designed and manufactured the teflon box(here after TLD holder) to put TLD in. The external size of TLD holder is $4\times4\times1\;mm^3$ To estimate the effect of TLD holder on TLD response for radiation, the linearity of TLD response to nominal dose were measured for TLD in TLD holder. Measurement were peformed in the 10 MV x-ray beam with LiF TLD using a solid water phantom at SSD of 100 cm. Percent Depth Dose (PDD) and Tissue-Maximum Ratio (TMR) with varying phantom thickness on TLD were measured to find the effect of TLD holder on the dose coefficient used for dose calculation in radiation therapy. Results : The linearity of response of TLD in TLD holder to the nominal dose was improved than TLD only used as dosimeter And in various measurement conditions, it makes a marginnal difference between TLD in TLD holder and TLD only in their responses. Conclusion : It was proven that the TLD in TLD holder as a new dosimetry could be used in vivo dosimetry.

  • PDF

Decreased in vivo Tyrosine Hydroxylase Activities with Normal Norepinephrine Levels in Streptozotocin-Induced Diabetic Rat Hypothalamus (Streptozotocin-유발 당뇨쥐의 시상하부에서 Norepinephrine 함량은 정상이나 In vivo Tyrosine Hydroxylase 활성은 감소함)

  • Wie, Myung-Bok;Song, Dong-Keun;Kang, Byung-Tae;Jung, Jun-Sub;Choi, Yeun-Sik;Park, Joon-Hyoung;Kim, Yung-Hi
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.1
    • /
    • pp.1-5
    • /
    • 1991
  • We studied changes in the hypothalamic norepinephrine(NE) metabolism in streptozotocin (STZ)-induced diabetic rats by measuring basal NE levels, turnover rate of NE, and in vivo tyrosine hydroxylase activities. Basal NE level did not change significantly upto 4 weeks after the establishment of diabetes with STZ(60 mg/kg, iv). But turnover rate of NE decreased to 62% of control rate(P<0.01), and in vivo tyrosine hydroxylase activities decreased to 32% of control level(P<0.05) at one week of diabetes. From these results, we concluded that, of the three parameters measured, in vive tyrosine hydroxylase activity is the most sensitive index of altered hypothalamic NE metabloism in STZ-induced diabetic rats.

  • PDF

Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy (방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발)

  • Hwang, Ui-Jung;Baek, Tae Seong;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The purpose of this study is to evaluate the developed dose verification program for in vivo dosimetry based on transit dose in radiotherapy. Five intensity modulated radiotherapy (IMRT) plans of lung cancer patients were used in the irradiation of a homogeneous solid water phantom and anthropomorphic phantom. Transit dose distribution was measured using electronic portal imaging device (EPID) and used for the calculation of in vivo dose in patient. The average passing rate compared with treatment planning system based on a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 95% for the in vivo dose with the homogeneous phantom, but was reduced to 81.8% for the in vivo dose with the anthropomorphic phantom. This feasibility study suggested that transit dose-based in vivo dosimetry can provide information about the actual dose delivery to patients in the treatment room.

The Study on the Skin Penetration of Cosmetic Ingredient with in vivo Raman Spectroscopy and in vitro Franz Cell (라만 분광 피부 측정기를 이용한 기능성 화장품 성분의 in vivo 피부 투과 측정 및 in vitro 비교 평가 연구)

  • Jeon, Serim;Han, Min-Hee;Chung, Dae-Kyun;Hwang, Jae-Sung
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • At present, there are few research papers on skin penetration of cosmeceutical ingredients. What is worse is that in vivo studies are hard to find. In this study, we measured skin epidermal penetration of cosmeceutical ingredients using in vivo Raman spectroscopy and compared with the results obtained from experiments using in vitro franz cell. Results showed that ascorbyl-2-glucoside, retinol, retinyl palmitate, and kojic acid were good for penetration ratio in measurement in vitro and retinol, vitamin C, and arbutin were good in measurement in vivo. Among them, retinol was best in skin penetration in vivo experiment using Raman spectroscopy and ascorbyl-2-glucoside was best in skin penetration in vitro experiment using Franz cell system. It is estimated that the differences were originated from the experimental procedures of two different methods; in vivo Raman experiment can be sensitive to the effect of epidermis and dermis as characteristics of matter by estimating the stratum corneum and in vitro measurement is evaluation of material to penetrate skin of hairless mouse. However, most penetration barrier is the stratum corneum, thus it is important to examine movement of material in the stratum corneum. We expect that these results provided useful information for many cosmetic related research.

In-vivo Measurement of Cucumber to Detect N-Deficient Stress (오이의 질소결핍 장해 진단을 위한 생체정보 수집)

  • 성제훈;류육성;서상룡;정갑채
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.07a
    • /
    • pp.171-176
    • /
    • 1999
  • 작물의 생육장해 진단은 식물체의 계측에 의해 수행되는데, 이러한 계측은 생육 중인 작물을 대상으로 할 경우, 작물의 잎이나 줄기의 비파괴적 생체(in-vivo)계측을 필요로 하며 비접촉이면 더욱 바람직하다. 그리고 식물체의 건강상태를 좀더 신속하고 정확히 파악하기 위해서는 가능한 다양한 항목을 측정 대상으로 하여 관찰하는 것이 요구될 뿐만 아니라 많은 경우 그 관찰은 미소한 생장반응 및 생장량을 측정하여야 하므로 상당히 높은 정확도의 전문 센서가 필요하다. (중략)

  • PDF

Optimization of In Vivo Stickiness Evaluation for Cosmetic Creams Using Texture Analyzer (Texture Analyzer (TA)를 이용한 화장품 크림의 In Vivo 끈적임 평가법의 최적화)

  • Ryoo, Joo-Yeon;Bae, Jung-Eun;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.4
    • /
    • pp.371-382
    • /
    • 2020
  • There have been continuous attempts to quantify sensory attributes of cosmetic products by measuring relevant physical properties. The most representative method to evaluate stickiness is to measure axial force using texture analyzer. Stickiness is known to correlate with AUC which abbreviates area under curve in the obtained axial force curve as a function of time. Recently, Normandie University research group developed in vivo stickiness evaluation method considering the characteristics of skin along with established evaluation method[8]. Based on the study, we tried to optimize in vivo stickiness evaluation method especially for cosmetic creams. The experiment was carried out on 5 different facial creams products by changing the amount and the times of rolling of creams, and the shape and material of probes. Based on the results of the sensory evaluation, the most consistent conditions were established as the optimal evaluation method. As a result, applying 70 μL of cream and rubbing 10 times for 7 s inside the 3.4 cm circle were judged to be suitable. As for the probes, spherical metallic probe was more proper due to its reproducibility. We conducted the settled method on 10 subjects to check its validity. Although the absolute values of AUC differed depending on the individuals, the AUC values were all ranked the same. Finally, for the standardization of stickiness of AUC, polyvinylpyrrolidone (PVP) was set as a reference material and we measured AUC of its aqueous solution by changing concentration. Then, the degree of stickiness recognition for 5 different creams was surveyed to check the correlation between AUC and stickiness.