• Title/Summary/Keyword: impressions

Search Result 425, Processing Time 0.026 seconds

The effects of custom tray material on the accuracy of master cast reproduction

  • Kim Hyun-Kyung;Chang Ik-Tae;Heo Seong-Joo;Koak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.282-296
    • /
    • 2001
  • The accuracy of master cast reproduction by a polyvinylsiloxane impression material using two visible-light curing resin and autopolymerizing polymethyl methacrylate resin custom tray material was investigated. Custom trays were fabricated from a master cast that had three index points marked on both inner and outer vestibules and then poured in yellow stone. The distance between the reproduced index points were measured to be ${\pm}0.001mm$ with a measuring microscope and the algebraic norms calculated for each tray material. No differences were found in the algebraic norms of inner and outer dimensions for upper tray impressions by ANOVA(p>0.05). However, T-test revealed that there were differences between upper and lower impressions and Tukey's hsd test revealed that in lower tray impressions, the Palatray in inner, the Lightplast in outer dimensions respectively were different from other materials. The index points reproduced on the casts compared with the master cast, were closer together for upper tray impressions. All four tray materials produced acceptable casts, 1. Algebraic norms of inner and outer dimensions of the test casts for upper trays were not statistically different irrespective of materials.(P>0.05) 2. T-test showed that there were differences between means with upper and lower trays especially in outer dimension.(P>0.05) 3. But, algebraic norms of inner and outer dimensions of the test casts for lower trays were statistically different between materials. 4. Palatray XL in inner, Lightplast-platten in outer dimensions respectively for lower trays were different from other materials, but, the nearest to the original model.

  • PDF

The Infection Control of Dental Impressions (치과용 인상체의 감염 관리)

  • Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.183-193
    • /
    • 2013
  • The characteristics of dental treatment makes the dental staff frequently contact with patient directly. Also the daily use of high-handpieces, sharp instruments, and needles often causes bleeding on oral cavity. Therefore, the risk of cross transmission grows up. The pathogen from dental practice could spread on not only the practice itself but also the dental laboratory with contaminated impressions and prosthesis. Dental clinic staffs (dentists, dental hygienists and dental technicians) should recognize all the patients have a possibility of cross contamination, and try to prevent the transmission of infection by proper infection control. In this study, we review the articles about disinfection methods and chemical infection agents used for dental impressions, and try to figure out the suitable and effective infection control system of dental impressions.

Modernism, History, and Memoir-Writing in Ford Madox Ford (″소설가는 그 시대의 사학자이다″: 모더니즘과 포드 매독스 포드의 회고록 쓰기)

  • Hyungji Park
    • Lingua Humanitatis
    • /
    • v.1 no.2
    • /
    • pp.91-104
    • /
    • 2001
  • Ford Madox Ford, the early twentieth-century writer most famous for his novel The Good Soldier, perceived his "business in life [as an] ... attempt to discover and to try to let you see where you stand." With this grand purpose in mind, Ford disregarded distinctions of genre in his prolific output of what we would consider novels, memoirs, literary criticism, travel writing, and history. Claiming that "the Novelist ... [is a] historian of his own time," Ford sought his own version of the "truth," a truth that was more faithful to his own subjective impressions than to verifiable "fact." Among these works that depict his age are a series of "memoirs" or "reminiscences," works published from the 1910s to the 1930s which carry out his Impressionistic purpose. What lies behind these memoirs is Ford′s view that his own individual history can be understood as his contemporary society′s collective history. This article explores Ford′s experimentation with boundaries of fact and fiction, and history and narrative, as he employs and expands the memoir form. In particular, 1 focus on two works, Memories and Impressions (1911) and It Was the Nightingale (1933), and Ford′s techniques in these memoirs, such as 1) the adoption of fictional personae from which to comment on his society at large and 2) the use of emblematic "parables" to encapsulate larger lessons of life within the minutiae of existence. Current theorists on the memoir form share interests in these questions of genre and of the social role of the memoir Nancy Miller, for instance, terms the memoir "the record of an experience in search of a community." This article engages these current discussions of the memoir genre by examining Ford′s early twentieth-century examples as innovative experiments that play with the boundaries between fiction and history, and personal impressions and collective truth.

  • PDF

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

Effectiveness of the novel impression tray "cleftray" for infants with cleft lip and palate: a randomized controlled clinical trial

  • Kalaskar, Ritesh;Bhaje, Priyanka;Balasubramanian, Shruti;Kalaskar, Ashita
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.2
    • /
    • pp.82-90
    • /
    • 2021
  • Objectives: Cleft lip and palate (CLP) is one of the most common congenital deformities with worldwide prevalence. It causes a range of issues for infants that mainly involve difficulty in feeding due to abnormal oronasal communication. For this purpose, feeding plates are provided to infants to act as an artificial palate to aid in feeding. The most crucial procedure in fabrication of a feeding plate is creation of the impression using the traditional finger technique or impression trays. This preliminary research aims to compare the effectiveness of novel impression trays with that of the traditional finger technique for recording impressions of infants with CLP. Materials and Methods: This randomized controlled trial was conducted among 30 infants who were divided into two groups based on the method of obtaining impressions: Group I, finger technique; Group II, specialized acrylic tray (cleftray). Results: Use of cleftray required less impression time, a reduced amount of material, no incidence of cyanosis/choking in infants, and lower anxiety among doctors compared to the traditional method. Additionally, there was no distortion of cleft impressions, recorded maxillary tuberosity, or other fine details. Therefore, the novel impression tray (cleftray) exhibited superior outcomes in all the parameters compared to the finger technique. Conclusion: Within the limitations of this study, we conclude that impression trays are superior to the traditional finger, spoon, or ice cream stick methods of creating impressions of CLP. However, it is necessary to conduct more clinical trials on a larger population based on other parameters to compare the effectiveness of the two techniques to draw definitive conclusions.

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

The Effects of Body shapes and Apparel Colors on male Children′s Impression (체형 및 의복 색이 남자아동의 인상형성에 미치는 영향)

  • 김재숙;송경자
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.2
    • /
    • pp.29-37
    • /
    • 2002
  • The purpose of this study was to examine the effects of bodyshape and clothing color on boy's impression. The subjects were composed of 480 elementary students, 11-12 years old. The stimuli were consisted of 12 color photographs by using CAD system that was different in the bodyshape, the clothing color and the level of contained color each other. The subjects reported the stimuli's pression on the questionnaires. The image of the stimuli were emerged 5 differented dimensions ; attractiveness, evaluation, potency, bodyshape, visibility. The boy's impressions of normal bodyshape were more attractive, positive evaluation and thin than obese bodyshape. The boy's impressions who was dressed in pink color shirt were thin than blue color. The boy's impressions were positive evaluation when he was dressed in shirt with pink or blue color in collar and cuffs and the whole. The boy's impression of normal bodyshape wearing blue color shirt was the most attractive but the boy's impression of obese bodyshape wearing pink color shirt was not charm. The boy's evaluation who was normal bodyshape wearing pink color shirt was the most positive and the most thin.

THE INFLUENCE OF IMPRESSION MATERIALS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE ARCH IMPRESSION (전악인상채득시 인상재가 경석고 모형의 정확도에 미치는 영향)

  • Lee, Soo-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.207-218
    • /
    • 1993
  • The purpose of this study was to evaluate the reproducing accuracy of stone casts made from complete arch impressions using different impression materials. The impression materials studied were 1) polyether, 2) polysulfide, 3) polyvinyl siloxane, and 4) irreversible hydrocolloid. Impressions were made from a partially edentulous acrylic resin model with metal inserts in canine, first molar region bilaterally and mid palatal vault region. Each distance between 2 out of 5 meauring points was measured by using 3dimensional measuring machine. Impressions were poured at once with a type IV dental stone. Data were analyzed using t-test with a sample size of six. The results were as follow : 1. Polysulfide and polyether were significantly superior to polyvinyl siloxane and irreversible hydrocolloid in reproducing full arch model(p<0.05), but there were no statistical differences in amount of dimensional reproducing accuracy for full arch impression between polysulfide and polyether(p>0.05). 2. There were statistical differences in amount of dimensional reproducing accuracy between edentulous area and tooth bound area for polysulfide and polyether(p<0.05). but no statistical differences were observed for polyvinyl siloxane and irreversible hydrocolloid(p>0.05).

  • PDF

Effects of Motif Categories and Colors of Dress on Evaluating Impressions of Dress Wearers - Focusing on Male and Female University Students - (의복의 색과 문양이 의복착용자 인상에 미치는 영향 - 남녀 대학생을 중심으로 -)

  • Lee, So-Ra;Kim, Jae-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.7
    • /
    • pp.1160-1168
    • /
    • 2008
  • The purpose of the study was to examine the effect of motif categories and motif colors on evaluating impressions of dress wearers. The research was conducted on a quasi experimental basis, with subjects numbering 187 male and 207 female college students. Data were collected in the period from march 19th to march 31st, 2007. A set of stimuli of dress wearers and semantic differential scales were developed. The stimuli were thirteen photographs editing by Youngwoo CAD system. Variables included; (a) motif colour(red, blue, achromatic and white) (b) motif categories(flower, paisley, stripes, zebra effect and plain). The semantic differential scale to measure impressions of dress wearer stimuli included 22 sets of hi-polar adjectives. The data were analysed by factor analysis and ANOVA and the major finding were as follows. Four factors emerged to account for dimension of impression. There were salience, attractiveness, comfort and femininity. The motif category effected on the four impression dimensions while the motif color effected on salience, comfort and softness sensory dimensions, and the results supported the gestalt theory of the impression perception.

Effects of Attributes of Food Courts and Emotions on Customer Revisit Intention (푸드코트 속성과 감정이 고객 재방문에 미치는 영향)

  • Jo, Hayoung;Lee, Hyunjoo;Choi, Jinkyung
    • Journal of the Korean Society of Food Culture
    • /
    • v.31 no.1
    • /
    • pp.73-80
    • /
    • 2016
  • The purpose of this study was to identify the change attributes of food courts inside department stores or shopping centers, which are becoming more sophisticated and gentrified. A survey was conducted regarding customer satisfaction level of food services, which influences customers' revisit behavioral intentions, to provide future development direction. Using an exploratory factor analysis, 55 questions on food and beverage service, atmosphere, comfort, sanitation, and food quality were produced. This study tested how these choice factors affect customers' positive or negative impressions of their dining experiences through multiple regression analysis. Results indicate that 'food service' was the most important factor contributing to customers' positive impressions along with higher revisit behavioral intentions. On the contrary, respondents who received poor 'food service' had higher negative impressions with low revisit intentions. The results and findings of this study will positively influence marketing and customer relationship management and thus help design of successful strategies for food court development.