• 제목/요약/키워드: impression trays

검색결과 31건 처리시간 0.019초

한국형 유치악용 기성트레이의 개발에 관한 연구 (DEVELOPMENT OF DENTULOUS STOCK TRAYS FOR KOREANS)

  • 송대성;강석구;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.755-779
    • /
    • 1996
  • This study was designed to development of stock tray for Korean. The subjects for this study were 374 persons(male : 204, female : 170) with age $19{\sim}28$. The study models were made with irreversible hydrocolloid impression material and conventional stock tray, Individual trays were made on the study model and the master models were made after impression with polysulfide rubber impression material. Each of the master models measured 12 measuring points on the maxillary model and 13 measuring points on the mandibular model with digital sliding caliper. The values were analyzed statistically by SAS analysis. The measuring points were analysed and were consulted for the development of new stock tray for Korean. Maxillary models were divided into four groups acceding to the width between buccal alveolar ridges below the contact point of first molar and second molar. The size of new tray of the upper first group was 82mm (width), 60mm(length). That of the upper second group was 77mm (width), 59mm (length). That of the upper third group was 72mm (width), 58mm (length). And that of the upper fourth group was 67mm (width), 57mm (length). Mandibular models were devided into three group according to the width between lingual alveolar ridges below the second molar. The size of new tray on lower first group was 40mm (width), 55mm (length). That of the lower second group was 36mm (width), 55mm (length). And that of the third group was 32mm (width), 55mm (length). The author tested the fitness of newly designed stock tray in 52 subjects with normal occlusion and obtained good results that the problems of conventional stock tray were worked out.

  • PDF

한국인 성인에 대한 기성 tray의 적합도에 관한 연구 (A STUDY ON THE FITNESS OF STOCK TRAY IN KOREAN ADULTS)

  • 송대성;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.131-141
    • /
    • 1989
  • This study was designed to investigate the fitness of stock tray in Korean adults. 107 dental students (male: 87, female: 20) who have normal occlusion and symmetric facial fom were selected. The upper and lower stock tray (Osungtray, Osung Co., Korea) fit with dental arch were selected for taking irreversible hydrocolloid impression. The author measured the thickness of impression material about two items, that is, width and length on the flange of stock tray. Several measuring points on the dental arches and palatal area were checked with Goldman Fox prove (Hu-Friedy, U.S.A.). The obtained results were as follows: 1. The width of impression material on buccal flange of upper and lower trays were narrower than any other measuring point, but the thickness of impression material on the palatal area of upper stock tray was the widest of all measuring points. 2. The length on buccal flange of lower stock tray was shorter, but the length on tray flange of lower stock tray at lingual frenum area was longer. 3. On upper dental arch, the upper extra-large tray was used in 53% of subjects, but upper small tray was not used. 4. On lower dental arch, the large tray was used in 55% of subjects. 5. There was not adequate tray on upper dental arch in 4 subjects.

  • PDF

탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구 (ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS)

  • 김기홍;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태 (Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu)

  • 은정화;배지영
    • 한국치위생학회지
    • /
    • 제5권2호
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

Contour of lingual surface in lower complete denture formed by polished surface impression

  • Heo, Yu-Ri;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.472-478
    • /
    • 2016
  • PURPOSE. The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. MATERIALS AND METHODS. Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. RESULTS. Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. CONCLUSION. The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구 (A comparative study on the accuracy of impression body according to the types of impression tray)

  • 이현정;임종화;이준석
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.48-54
    • /
    • 2010
  • 연구 목적: 보편화된 임플란트 치료의 장기적인 성공을 위해서는 임플란트와 상부 보철물의 연결 시 완전한 수동적 적합을 이루는 것이 중요하며, 이를 위해서는 정확하게 인상 채득하는 것이 필요하다. 이 연구에서는 임플란트 고정체 수준 인상 채득 방법 중 인상체 제거 후 인상용 코핑이 인상체에 남아있는 open tray 인상법과 구강 내에 남아있는 closed tray 인상법, 그리고 인상 채득 시 사용될 수 있는 여러 트레이에 대해 비교 연구해 보고자 하였다. 연구 재료 및 방법: 실험 모형은 하악 악궁 형태로 열중합형 아크릴릭 레진을 이용하여 제작하였고, vertical gap을 관찰할 20 mm 간격의 기준 구조물을 제작한 후 이를 이용하여 실험 모형에 임플란트 유사체를 매몰하였다. 실험군은 트레이 레진으로 제작한 개인 트레이, 폴리카보네이트 기성 트레이 그리고 금속 기성 트레이 등의 3가지 트레이를 이용하였고, closed tray 인상법과 open tray 인상법의 2가지 인상 채득법에 따라 5개 군으로 나누었다. 그리고 위치에 따른 오차를 관찰하기 위해 시편 모형을 전치부, 구치부로 다시 나누어 총 10개의 실험군을 구성하였다. 1군당 총 9개의 시편을 제작하였고, 시편에 기준 구조물을 한 쪽 지대주만 20 Ncm으로 고정시킨 후 관찰하는 1-screw test를 이용하여 반대쪽의 임플란트 유사체와 지대주와의 gap을 입체 광학 현미경을 이용하여 관찰하였다. 1시편당총6부위를 측정하였고, 3회씩 측정하여 동일한 결과를 얻었을 때 수치를 기록하여 통계 처리하였다. 결과: Closed tray 인상법 사용 시 폴리카보네이트 기성 트레이와 개인 트레이 간에 유의한 차이를 보였지만, open tray 인상법 사용 시 폴리카보네이트 기성 트레이와 개인 트레이 간에 유의한 차이를 보이지 않았다. 폴리카보네이트 기성 트레이를 이용한 인상 채득 시 open tray 인상법과 closed tray 인상법 간에 유의한 차이를 보였고 (P<.05), 폴리카보네이트 트레이를 이용한 closed tray 인상법을 개인 트레이를 이용한 open tray 인상법과 비교 시 전치부, 구치부 모두에서 유의한 차이를 보였다 (P<.05). 결론: 폴리카보네이트 기성 트레이를 사용 시에는 open tray 인상법이 더 추천되는 바이며, 생체 외 실험의 한계성에 유의해야 하며, 정확한 임플란트 고정체 수준 인상 채득에 대해 더 많은 연구가 필요하다고 사료된다.

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

상악골 결손부 환자에서 3D printing을 이용한 closed hollow bulb obturator 수복 증례 (Prosthetic rehabilitation for a maxillectomy patient using 3D printing assisted closed hollow bulb obturator: a case report)

  • 오미주;이종혁;송영균
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.191-198
    • /
    • 2019
  • 본 증례는 상악골 결손이 있는 무치악 환자에서 3D printing을 이용해 closed hollow bulb obturator로 수복한 증례이다. Magic $denture^{TM}$ 시스템(Cozahn, Seoul, Korea)에서 제공하는 트레이와 인상법을 이용하여 구내 인상을 채득하였고, 시적의치상에서 수직고경과 안모, 유지력 등을 확인하였다. 환자가 요구하는 바와 오차를 시적의치에서 수정한 후 이를 반영하였다. 의치의 무게를 줄이고 균일한 두께를 부여하기 위해 상악골 결손부위를 closed hollow bulb로 디자인하여 최종의치상을 프린팅하였다. 치료 후 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

The Dentists' View of Dental Hygienist Duties in Korea

  • Han, Yang-Keum;Yu, Ji-Su;Kim, Seung-Hee;Yang, Jin-Young;Bae, Soo-Myoung;Hwang, Soo-Jeong
    • 치위생과학회지
    • /
    • 제20권1호
    • /
    • pp.34-43
    • /
    • 2020
  • Background: The number and curriculum of dental hygienists in Korea have dramatically increased. Controversies have since resulted from insufficient job descriptions of the work performed by a dental hygienist. A dentist's perception was examined to legally reflect the actual work of dental hygienists. Methods: Four hundred and nineteen dentists were surveyed about the duties of a dental hygienist. Their views on the career and availability of each job were examined. The duties of the dental hygienist include 13 items in dental treatment preparation, 14 items of radiography, 21 items of preventive dentistry, 6 items of periodontal treatment, 12 items of oral medicine, 12 items of conservative dentistry, 8 items of prosthetics, 10 items of orthodontics, 7 items of oral and maxillofacial surgery, 6 items of implantation, 6 items of impression taking and model fabrication, 5 items of anesthesia and injection, 11 items of management and administrative, and 3 items of self-development. Results: Most of the duties were doable by a dental hygienist. Many dentists reported that managing implants, oral hygiene of special patients, some duties in oral medicine, teeth brightening, making temporary crowns, making individual trays, selecting shades, ligaturing, and precision impressions need ≥3 years of experience. Duties perceived by dentists not to be performed by dental hygienists were reading radiographs (55.4%), suture and stitch out (48.0%), intramuscular injection (36.0%), root planning (27.2%), cementation and removal of prostheses (23.2%), and examining pulp vitality (22.0%). Conclusion: Current laws are to be revised to include, the care provided by dental hygienists and under a physician's supervision. Flexibility is also needed to cope with rapidly changing dental technology.