• Title/Summary/Keyword: impression materials

Search Result 313, Processing Time 0.035 seconds

The Visual Evaluation of the Image of Korean Dress according to Color Coordination (컬러 코디네이션에 따른 한복 이미지의 시각적 평가)

  • Kang, Kyung-Ja;Paeng, Suk-Kyung
    • Korean Journal of Human Ecology
    • /
    • v.16 no.5
    • /
    • pp.987-996
    • /
    • 2007
  • The purpose of this study is to find out the effect of three clothing cues(jacket color, skirt color, and tone of Korean dress) on the image of Korean dress wearer using tone-in-tone coloration. The experimental materials developed for this study are a set of stimuli and response scales. The stimuli are 16 color pictures manipulated with three clothing cues by drawing. The 7-point scale designed for visual evaluation of female impression formation includes 24 bipolar adjectives. The subjects were 192 undergraduate female students in Chinju city. The results of this study are as follow: As analyzing the image of female figure by the jacket color, skirt color, and tone, three factors including youth activity, attractiveness, and visibility were identified. Among these factors, youth activity and attractiveness were proved to be more important. Each dimensional image was affected by color coordination of jacket color, skirt color and tone of korean dress. Therefore, the image of Korean dress wearer could be varied by color coordination of jacket color, skirt color and tone of Korean dress.

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

The Effect of Exchange and Correlation on Properties of Carbon Nanotube Structure: A DFT study (탄소 나노 튜브 구조의 특성에 대한 교환과 상관 효과: DFT 연구)

  • Bakhshi, K.;Mollaamin, F.;Monajjemi, M.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.7-13
    • /
    • 2011
  • As an aid towards improving the treatment of exchange and correlation effects in electronic structure calculations, it is desirable to have a clear picture of concepts of exchange-correlation functionals in computational calculations. For achieving this aim, it is necessary to perform different theoretical methods for many groups of materials. We have performed hybrid density functional theory (DFT) methods to investigate the density charges of atoms in rings and cages of carbon nanotube. DFT methods are engaged and compared their results. We have also been inclined to see the impression of exchange and correlation on nuclearnuclear energy and electron-nuclear energy and kinetic energy. With due attention to existence methods, B3P86, B3PW91, B1B96, BLYP and B3LYP have used in this work.

Technique for fabricating a mandibular suction denture with a plastic implant tray (임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법)

  • Lee, Ju-Hyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Even though implant overdentures are preferentially recommended to mandibular edentulous patients, many patients may select conventional complete dentures due to cost and general condition. Proper retention and stability of conventional complete dentures in patients with severe alveolar bone resorption is difficult to achieve. To overcome the limitations, mandibular suction dentures with the closed mouth impression technique have been used. However, the previous technique requires the Frame cut back tray, the Centric tray, and the Gnathometer M. This article introduces a technique for fabricating a mandibular suction denture with common dental materials.

Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study

  • Gozde, Kaya;Caglar, Bilmenoglu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.388-398
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept. MATERIALS AND METHODS. Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed. For the control group, the gypsum model was scanned 10 times with an industrial scanner. The first of the 10 virtual models obtained from the industrial model was chosen as the reference model. For trueness, the data of the 14 dental scanners were superimposed with the reference model; for precision, the data of all 14 scanners were superimposed within the groups. Statistical analyses were performed using the Kolmogorov-Smirnov, Shapiro-Wilks, and Dunn's tests. RESULTS. Primescan showed the highest trueness and precision values (P < .005), followed by the iTero 5D scanner (P < .005). CONCLUSION. Some of these digital scanners can be used to make impressions within the All-on-4 concept. However, the possibility of data loss due to artifacts, reflections, and the inability to combine the data should be considered.

Knit fashion design by application of a flower image of Georgia O'Keeffe painting (조지아 오키프(Georgia O'Keeffe) 회화의 꽃 이미지를 응용한 니트 패션 디자인)

  • Kim, Hyeon-Yeong;Lee, Younhee
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.2
    • /
    • pp.180-197
    • /
    • 2016
  • The purpose of this study is to create knit ruffles that represent the aesthetic and artistic values of painted works of art that rhythmically express flower petals and add an artistic impression on the knit ruffle designs. This study is based on the artistic life of Georgia O'Keeffe and changes in her artistic background, and the world of paintings. The relevant data was gathered from domestic and foreign references, academic journals, and the internet. The characteristics of Georgia O'Keeffe paintings were examined. Her paintings typically include a series of various motifs, symmetry, balance, and harmony of detailed realistic expressions and abstract elements, repetition, and the principles of contrast and emphasis in shaping. The decoration techniques used on fabrics were applied using the knitting machine which controls the tension to develop a variety of textures, apart from the previous standardized knit textures, through various knitting techniques. A gradation effect was then applied by piece-dyeing the knitted materials in various colors to express asimilarity to the original colors in O'Keeffe's works with delicate color expressions. After the piece-dyeing, the decorative knitted materials were trimmed on a model to re-create the natural curves of flower petals. This study aims to converge works of art with fashion designs to develop various creative knitted fashion and to impart an artistic sense in the fashion design industry.

A Study on the 'Transparency' of Office Lobbies (오피스 로비 공간에 나타난 '투명성'의 표현에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.113-118
    • /
    • 2006
  • The lobby is the space that contributes the most to conveying the first impression of an enterprise or company that is occupying a building, and enhances the quality of the urban or business environment around an office building. Transparency is the biggest change in architecture since the modern age began, and it is the most important element of the lobby expression methods. Therefore this study was an attempt to understand the expression method of transparency which is expressed in the lobby space of office buildings, and used documentary survey and field survey to analyze it. In the examination of the theoretical background of transparency to make a specific study purpose, and based on an on-the-spot probe document, an attempt was made to grasp the expression method of Visual Transparency and Phenomenal Transparency. The data collected during this investigation was studied and a correlation coefficient. A summary of the findings of this study is as follows: 1) Transparent materials does not appear often in floors. But Phenomenal Transparency material is used in the floor. 2) During the survey it was discovered that Visual Transparency was often used in the walls of each investigated building. Phenomenal Transparency materials are found less in walls than in the floors of lobbies. 3) The expression methods that appeared the most in ceilings among the Visual Transparent expression methods. In the case of Phenomenal Transparency, the highest distribution is seen in ceilings. 4) The result of the analyzation of the correlation coefficient of Visual Transparency and Phenomenal Transparency is as follows: Expression method: There is more than one expression method of transparency, 'Open Sight', 'Light Material' and 'Surface Material' methods were introduced in case of the introduction of 'Transparent Material' among Visual Transparency in office building lobby space planning. If the 'Superimposed Space' method is introduced, then the 'Ambiguous Border' or 'Dual Sight' methods are introduced.

  • PDF