• Title/Summary/Keyword: impression material

Search Result 202, Processing Time 0.026 seconds

DEVELOPMENT OF DENTULOUS STOCK TRAYS FOR KOREANS (한국형 유치악용 기성트레이의 개발에 관한 연구)

  • Song, Dae-Sung;Kang, Seok-Ku;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.755-779
    • /
    • 1996
  • This study was designed to development of stock tray for Korean. The subjects for this study were 374 persons(male : 204, female : 170) with age $19{\sim}28$. The study models were made with irreversible hydrocolloid impression material and conventional stock tray, Individual trays were made on the study model and the master models were made after impression with polysulfide rubber impression material. Each of the master models measured 12 measuring points on the maxillary model and 13 measuring points on the mandibular model with digital sliding caliper. The values were analyzed statistically by SAS analysis. The measuring points were analysed and were consulted for the development of new stock tray for Korean. Maxillary models were divided into four groups acceding to the width between buccal alveolar ridges below the contact point of first molar and second molar. The size of new tray of the upper first group was 82mm (width), 60mm(length). That of the upper second group was 77mm (width), 59mm (length). That of the upper third group was 72mm (width), 58mm (length). And that of the upper fourth group was 67mm (width), 57mm (length). Mandibular models were devided into three group according to the width between lingual alveolar ridges below the second molar. The size of new tray on lower first group was 40mm (width), 55mm (length). That of the lower second group was 36mm (width), 55mm (length). And that of the third group was 32mm (width), 55mm (length). The author tested the fitness of newly designed stock tray in 52 subjects with normal occlusion and obtained good results that the problems of conventional stock tray were worked out.

  • PDF

Dimensional stability of rubber impression materials immersed in iodophor disinfectant (요오드 소독제에 침전된 고무인상재의 체적안정성)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Purpose: The purpose of this study was to determine the dimensional stability of three rubber impression materials (polysulfide, polyvinylsiloxane, polyether) in an iodophor disinfectant. Materials and Methods: Seventy-two impressions were made with each material and divided into control, 10-minute, and 30-minute immersion groups using an iodophor as the disinfectant. A microscope was used to measure dimensional changes in the stone casts made from each group of impressions, and the percent change was analyzed using a two-way ANOVA (P = 0.05). Results: All dimensional changes after iodophor disinfection were small in 10 minute groups, however, showed significantly increased in 30 minute groups (P < 0.05). Conclusion: Clinically, it can be recommended to use iodophor disinfectant for rubber materials within 10 minute.

Silicone impression material

  • Miller, Newell
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.15-34
    • /
    • 1963
  • 최근(最近) 칠위의 silicone products는 다음의 physical properties에 관련되어서 연구(硏究)되였다. 즉, initial and final setting Time Catalyst 양(量)에 있어서 변화의 영향, 혼합된 paste의 항구성(恒久性), 탄력성(彈力性) dental stone 과의 적합성 Electro forming properties shelf life 등이다

  • PDF

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

A Study on illusion of Clothing Design Factors Variation Effecting Perception of Face (의복디자인 요소 변화에 의한 착시현상이 얼굴지각에 미치는 영향에 관한 연구)

  • Lee, Mi-Jeong;Kim, Jun-Beom;Lee, In-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.8
    • /
    • pp.1287-1296
    • /
    • 1997
  • The purpose of the study is to make experimental whether three-dimensional body (especially face) has illusion based on theoretical background of form dimensions and color bright among precedent multi-form illusion, using the function of computer simulation. To investigate illusion that factors of clothing design(line, color, material) effect face, as the following is tried to solve giving change to neckline, collar, scarf which is believed to influence near face. How to make experiment as follows watching in order 13 scenes of a pair of with basic design and experiment design. Then the data were subjected to analysis of variance and Duncan's multiple range test. The result of this studying as follows, 1. Face looks larger in complex neckline than simple neckline. The larger collar is the larger face looks. 2. In white jacket, illusion(the lower luminosity of scarf color gets, the brighter face brightness gets) is shown. In black jacket, also illusion(the higher luminosity of scarf color gets, the darker face brightness gets) is shown. 3. In experiment on hardness and softness of face impression according to the material of collar, collar of knit and fur gives us assimilation illusion bring softer impression of face.

  • PDF

A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES (수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구)

  • Cho Lee-Ra;Chung Kyung-Ho;Kim Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.

A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology (Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구)

  • Kim, Jai-Min;Kho, Eun-Gyung;Chae, Soo-Chul;Kim, Soon-Ae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology refers to application of cellulose acetate filter material to the ocular surface to remove the superficial layers of the conjunctival epithelium. The technique is non-invasive, is easy to perform, causes minimal discomfort to the patient, and can be used to follow changes in the conjunctival ocular surface over time. With this method, the morphology of the conjunctival ocular surface can be studied and the degree of squmaous metaplasia assessed. This study was performed to evaluate the conjunctival surface by impression cytology in dry eye patients. A total of 70 students with no contact lens wearing history were recruited. Subjects were required to fill in a McMonnies dry eye symptom questionnaire. The non-invasive tear thinning time(TIT) test of each subject was measured, followed by Schirmer tear test(STI), tear film break-up time(TBUT) tests and Rose-bengal staining were performed as a baseline. Conjunctival epithelial cells from the inferior bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS(Periodic Acid Schift)-haematoxylin. The goblet cells and conjunctival epithelial cells were observed under a light microscope of 400x magnification. The specimens were classified according to the Nelson Grading scale which was based on the degree of squamous metaplasia such as changes of goblet cells density, size/form, N:C(nucleus : cytoplasm) ratio. Dry eye patients were observed morphological changes of the epithelial cells, different nuclear alterations, decrease of the goblet cells density. The degree of cytological changes was related to severity of dry eye conditions. When the epithelial cell morphology was graded according to the system described by Nelson, specimens from the control group revealed 91.43% of the eyes to be grade 0 and 8.57% to be grade 1, whereas of the dry eye patients, 20% were grade 0, 42.86% grade 1, 34.29% grade 2 and 2,86% grade 3. Impression cytology represents a non- or minimally invasive biopsy of the ocular surface epithelium with no side effects or contraindications. It has demonstrated to be a useful diagnostic aid for a wide variety of processes involving the ocular surface. This technique is a safe, simple method and may help increase understanding of various ocular surface alterations in dry eye patients.

  • PDF

A Research on the Life Span extension of Die Block in Cold Forging Die (냉간단조금형에서 다이블록의 수명연장에 관한 연구)

  • Kim, Sei-Hwan;Choi, Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.281-285
    • /
    • 2008
  • Die hobbing is one of the dieblock manufacturing methods of cold forging die, which makes the upper side of dieblock indented using master punch, hobb to produce impression not using cutting work. SKD11, alloy tool steel was used as the material of dieblock and stainless sheet metal was used as product material in cold forging work. The life span of the die was 6,000 strokes. In this research, the material of dieblock was changed into SKH51, the high speed tool steel and the product material was S45C, the carbon steel in the cold forging work. The life span of the die was 21,000 strokes, which is 350% of the life span of the die using the former method.

The effects of custom tray material on the accuracy of master cast reproduction

  • Kim Hyun-Kyung;Chang Ik-Tae;Heo Seong-Joo;Koak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.282-296
    • /
    • 2001
  • The accuracy of master cast reproduction by a polyvinylsiloxane impression material using two visible-light curing resin and autopolymerizing polymethyl methacrylate resin custom tray material was investigated. Custom trays were fabricated from a master cast that had three index points marked on both inner and outer vestibules and then poured in yellow stone. The distance between the reproduced index points were measured to be ${\pm}0.001mm$ with a measuring microscope and the algebraic norms calculated for each tray material. No differences were found in the algebraic norms of inner and outer dimensions for upper tray impressions by ANOVA(p>0.05). However, T-test revealed that there were differences between upper and lower impressions and Tukey's hsd test revealed that in lower tray impressions, the Palatray in inner, the Lightplast in outer dimensions respectively were different from other materials. The index points reproduced on the casts compared with the master cast, were closer together for upper tray impressions. All four tray materials produced acceptable casts, 1. Algebraic norms of inner and outer dimensions of the test casts for upper trays were not statistically different irrespective of materials.(P>0.05) 2. T-test showed that there were differences between means with upper and lower trays especially in outer dimension.(P>0.05) 3. But, algebraic norms of inner and outer dimensions of the test casts for lower trays were statistically different between materials. 4. Palatray XL in inner, Lightplast-platten in outer dimensions respectively for lower trays were different from other materials, but, the nearest to the original model.

  • PDF

RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS (유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Song Kie-Bum;Kim Sung-Rok;Park Kwang-Soo;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.