• 제목/요약/키워드: impression

검색결과 1,571건 처리시간 0.023초

인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화 (Change master cast by hardening method to position of tray after impression taking)

  • 이정애
    • 한국치위생학회지
    • /
    • 제8권2호
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구 (WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

인상채득 후 시간경과에 따른 고무인상재의 체적변화 (AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS)

  • 이홍석;조석규;윤태호;박주미;송광엽
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

인상공학에 의한 이동통신기기의 메뉴설계 (Mobile Phone Menu Design Based on Impression Engineering)

  • 김성택;손소영
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.417-420
    • /
    • 2000
  • The purpose of this paper is to design the menu of mobile phone based on the impression engineering. Free response survey analysis was used to collect impression data on mobile phone functions with time interval. Simultaneity analysis was applied to finding the relationship among selected impression. We cluster the related impression so as to design the menu of a mobile phone accordingly. This research is expected to contribute to the improvement of customer satisfaction by reflecting customer's impression in the process of product design.

  • PDF

인상공학에 의한 이동통신기기의 메뉴설계 (Mobile Phone Menu Design Based on Impression Engineering)

  • 김성택;손소영
    • 대한산업공학회지
    • /
    • 제26권4호
    • /
    • pp.431-438
    • /
    • 2000
  • The purpose of this paper is to design the menu of mobile phone based on the impression engineering. Free response survey analysis was used to collect impression data on mobile phone functions with time interval. Simultaneity analysis was applied to finding the relationship among selected impression. We cluster a set of the related impression so as to design the menu of a mobile phone accordingly. This research is expected to contribute to the improvement of customer satisfaction by reflecting customer's impression in the process of product design.

  • PDF

착용자 인상효과의 시간적 안정성 -의복범주, 유행성, 착용자의 체형 변인을 중심으로 - (Temporal Stability of Wearer′s Impression Effect - The Accent of Garment Category, Fashion-Level and Wearer′s Body Type -)

  • 김재숙;김희숙
    • 복식문화연구
    • /
    • 제10권1호
    • /
    • pp.28-36
    • /
    • 2002
  • The purposes of the study were to investigate the effect of garment category, fashion-level and wearer's body type on the basis of temporal stability and to extend the contextual framework. The result was as follows 1) On the basis of temporal stability, Korean style, classic style, and large body type have more temporal stability than western style, fashionable style, normal body type. 2) On the basis of temporal stability of impression dimension, impression of appearance knave most temporal stability, next good-bad, next evaluation, next potency, and sociability. 3) In an interaction effect between measuring time and impression of evaluation, western, fashionable, classic style have the greatest interaction effect. In an interaction effect between measuring time and impression of appearance, western style, normal body type have the greatest interaction effect. In an interaction effect between measuring time and impression of good-bad, western, fashionable style have the greatest interaction effect. It is concluded that the results support the context framework on impression formation.

  • PDF

보철 치료 시 디지털 및 전통적 인상채득에 대한 환자 만족도 비교 연구 (Comparison of patient satisfaction with digital and conventional impression for prosthodontic treatment)

  • 윤형인;이수민;박은진
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.379-386
    • /
    • 2016
  • 목적: 본 연구에서는 전통적 인상채득과 디지털 인상채득을 모두 경험한 환자들의 만족도를 조사하여 다양한 항목에 대하여 비교 분석하고자 하였다. 재료 및 방법: 구강 내 디지털 인상채득의 방법을 사용하는 5개의 치과병원에서, 보철 치료를 위해 기존의 인상재를 이용한 방법과 디지털 인상채득을 모두 경험한 만 20세 이상의 성인 환자 170명을 대상으로, 2015년 10월부터 2016년 4월까지 설문조사를 실시하였다. 총128부의 설문지를 분석 자료로 이용하였으며, 빈도분석, 다중응답 빈도분석, 기술통계, 비모수 검정, 교차 분석을 시행하였고, 유의수준은 0.05로 설정하였다. 결과: 디지털 인상채득의 이유는 '임플란트치료'(43.8%), '크라운치료'(30.5%), '인레이치료'(15.6%) 순서로 나타났다. 전통적 인상채득의 평균 만족도보다 디지털 인상채득의 평균 만족도가 유의하게 더 높았다 (P<.05). 재선택하고 싶은 인상채득 방법으로는 전통적 인상채득(11.7%) 보다 디지털 인상채득(60.2%)이 더 높게 나타났다. 디지털 인상채득을 재선택한 이유로는 '구토반사가 없어서'(35.1%), '3D디지털 스캔이라 신뢰가 가서'(33.8%), '시간이짧아서'(33.8%) 순으로 나타났다. 결론: 환자 만족도 및 다시 선택하고 싶은 인상채득의 방법으로 전통적 인상채득 보다 디지털 인상채득의 선택이 더 높게 나타났다.

임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교 (Comparative accuracy of implant impression techniques with different splinting materials)

  • 홍기윤;신수연
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.9-20
    • /
    • 2023
  • 목적: 하악 부분 무치악 모형에서 pick-up type 인상용 코핑을 사용한 개방형 인상 채득법과 transfer type 인상용 코핑을 사용한 폐쇄형 인상 채득법, 개방형 인상 채득법에서 pick-up type 인상용 코핑 고정 재료에 따른 인상 채득 정확성을 비교 하고자 하였다. 연구 재료 및 방법: 하악 부분 무치악 모형의 좌측 구치부에 직경 4.5 mm, 길이 11.5 mm의 임플란트 고정체 두 개 식립 후 3D 프린터를 이용하여 개방형 개인 트레이 30개 폐쇄형 개인 트레이 10개를 제작하였다. 제작한 개인 트레이를 이용하여 PN군: 개방형 인상 채득법(non-splint), PG군: 개방형 인상 채득법(splint GC pattern resin), PH군: 개방형 인상 채득법(splint Herifix), TN군: 폐쇄형 인상 채득법으로 나누어 각 군당 10회씩 총 40회의 인상 채득을 진행하였다. 인상채득 후 석고 모형을 제작하여 모델 스캐너로 스캔 후 역설계 프로그램으로 스캔오차를 측정하여 95% 유의수준으로 평가 하였다. 결과: 폐쇄형 인상 채득법 TN군이 개방형 인상 채득법 PN군 보다 더 낮은 오차값을 보였다. 개방형 인상 채득법(splint)에 사용된 인상용 코핑 고정 재료 간의 비교 결과에서는 PH군에서 가장 낮은 오차값을 보였으며 PN군, PG군 순으로 정확한 인상 채득 정확성을 보여주었다. 결론: 임플란트 인상 채득 방법이나 인상용 코핑의 연결 고정 유무에 따른 각 군 간의 정확성에 유의한 차이는 없다.

부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구 (A COMPARATIVE STUDY ON THE ACCURACY OF IMPRESSION METHOD USING ADDITION SILICONE PUTTY IMPRESSION MATERIAL)

  • 제홍지;정창모;전영찬;황희성
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.373-383
    • /
    • 1996
  • In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.

  • PDF