• Title/Summary/Keyword: implant stability

검색결과 495건 처리시간 0.028초

Effect and stability of miniscrew-assisted rapid palatal expansion: A systematic review and meta-analysis

  • Huang, Xinyi;Han, Yu;Yang, Shuangyan
    • 대한치과교정학회지
    • /
    • 제52권5호
    • /
    • pp.334-344
    • /
    • 2022
  • Objective: This study aimed to systematically analyze the effect and stability of miniscrew-assisted rapid palatal expansion (MARPE) to provide a reference for the clinical treatment of patients with maxillary transverse deficiency (MTD). Methods: We searched PubMed, Science Direct, Web of Science, Embase, Cochrane Library, CNKI, and Wanfang Database for relevant studies published before February 18, 2021 and selected them according to the eligibility criteria. The Cochrane Handbook for Systematic Reviews (version 5.1.0) criteria were used for the quality assessment of randomized controlled trials, while the scoring protocol of the methodological index for non-randomized studies was used for non-randomized controlled trials. Statistical analysis was performed using the RevMan5.3 software. Results: All the included studies showed a relatively high success rate of expansion. The changes in both the intermolar and alveolar widths after MARPE were statistically significant. MARPE exhibited greater skeletal expansion effects than did conventional RPE. The midpalatal suture was opened in parallel after MARPE. A small amount of relapse was observed 1 year after expansion. MARPE caused tooth inclination and a decrease in alveolar height, but it was less significant than in conventional RPE. Conclusions: MARPE may be an effective treatment modality for patients with MTD. It causes great transverse skeletal expansion in late adolescence. In comparison to conventional RPE, MARPE has lower detrimental periodontal effects and has certain clinical advantages.

Usability testing of a novel interlocking three-dimensional miniplate for mandibular angle fractures

  • Prasetyanugraheni Kreshanti;Aria Kekalih;Ahmad Jabir Rahyussalim;Sugeng Supriadi;Bambang Pontjo Priosoeryanto;Deni Noviana;Mendy Hatibie Oley;Chaula Luthfia Sukasah
    • 대한두개안면성형외과학회지
    • /
    • 제25권4호
    • /
    • pp.171-178
    • /
    • 2024
  • Background: We developed a novel interlocking three-dimensional (3D) miniplate design with an adjustable configuration. As this device is new, surgeons must become familiar with its application. This study evaluated the usability and learning curves associated with the novel interlocking 3D miniplate for mandibular fracture fixation. Methods: The study participants, nine plastic surgeons, were asked to apply an interlocking 3D miniplate and a standard miniplate to polyurethane mandible models. The participants had completed the Basic Craniomaxillofacial Osteosynthesis course during residency and had operated on craniomaxillofacial fractures within the past 5 years. They were instructed to place the interlocking 3D miniplate three times and the standard miniplate once. We assessed the time required for implant placement, the comfort level of the surgeons, and the biomechanical stability of the plates. Biomechanical testing was conducted by subjecting the mandible to forces ranging from 10 to 90 N and the displacement was measured. Results: The results indicate increasing comfort with each attempt at placing the interlocking 3D miniplate, with a significant difference between the first and third attempts. Additionally, a reduction in application time was noted with repeated attempts, suggesting improved efficiency. Biomechanical tests showed comparable stability between the tested plates. Conclusion: Multiple attempts at applying the interlocking 3D miniplate resulted in increased comfort and reduced application time. These findings indicate that, despite its novelty, the interlocking 3D miniplate is relatively straightforward to apply and has a short learning curve. However, surgeons must have specific qualifications to ensure proper training and minimize errors during placement.

알칼리와 열처리에 의한 임플란트의 표면 특성 및 골유착 안정성에 관한 연구 (Surface characteristics and stability of implants treated with alkali and heat)

  • 송윤석;조인호
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.490-499
    • /
    • 2008
  • 생체 활성 재료는 생체 내에서 자가적으로 인회석 층 (apatite layer)을 형성하여, 골과의 생화학적 결합이 가능해야 한다. 알칼리와 열처리를 통하여 생체 활성 표면을 얻을 수 있는 것으로 보고되고 있다. 본 실험에서는 알칼리 및 열처리를 시행한 임플란트들의 안정성을 평가하고자 하였다. 실험군의 분류로 1군은 대조군인 선반 가공 임플란트군, 2, 3군은 $60^{\circ}C$, 5 M의 NaOH 용액에 24시간 처리한 후, 각각 대기 중 및 진공 상태 $600^{\circ}C$에서 1시간 동안 열처리하였다. 처리된 시편은 FESEM, XPS, TF-XRD 및 AFM을 이용하여 표면 특성을 관찰하고, 임플란트의 안정성을 위해 공진 주파수와 페리오테스트 및 역 토오크를 측정하고, 골유착 안정성에 관한 차이를 비교 분석하여 다음과 같은 결과를 얻었다. 1. 표면 특성: 알칼리 및 열처리를 시행한 2, 3군은 비슷한 양상의 거친 표면을 보여주었다. 알칼리 처리를 시행한 2군과 3군에서 1군과는 달리 높은 함량의 나트륨 이온이 검출되었으며, 결정구조 분석 결과 2군에서 예추석 (antase)과 금홍석 (rutile)이 혼재된 상태로 금홍석이 우세한 양상을 보여주었다. 2. 공진 주파수 분석: 군간 비교에서 12주에 2군이 1, 3군에 비해 통계적으로 유의하게 높은 측정치를 보였다. 주간 비교시, 1, 2군은 4주 이후에 유의한 증가를 보여주었고, 3군은 2주와 4주에서 각각 유의한 증가를 보여주었다 (P < .05). 3. 페리오테스트 분석: 주간 비교에서 1, 2군은 4주 이후에 유의하게 감소를, 3군은 2주와 4주에서 각각 유의한 감소를 보여주었다 (P< .05). 4. 역 토오크 분석: 군간 비교에서는 2, 4, 8주에서는 2군이 1, 3군에 비해 유의하게 높은 측정값을 보여주었다. 주간 비교에서는 1, 3군은 4주, 12주에서 유의한 증가를 보여주었고, 2군은 4주부터 유의한 증가를 보여주었다 (P < .05). 이상의 결과로 볼 때, 알칼리 및 대기 중 열처리를 통해서 적절한 결정 구조의 산화막을 가진 생체 활성화된 무정형의 나트륨 티탄산염 층을 얻을 수 있었고, 알칼리 및 진공 상태 열처리만으로도 나트륨이 함유된 생체 활성화된 표면을 얻을 수 있었다고 사료된다. 또한 이런 처리 과정으로 형성된 표면층들은 임플란트의 초기 골유착에 도움을 줄 수 있는 유용한 방법 중 하나라고 사료된다.

RESONANCE FREQUENCY ANALYSIS OF IMPLANTS WITH ANODIZED SURFACE OXIDES

  • Choi Jeong-Won;Heo Seong-Joo;Chang Ik-Tae;Koak Jai-Young;Han Jong-Hyun;Kim Yong-Sik;Lee Seok-Hyung;Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.294-300
    • /
    • 2004
  • The present experimental study was designed to address two issues. The first was to investigate whether oxidation voltage of titanium implants influenced bone tissue responses after an in vivo implantation. The second aim was to investigate secondary stability change after 1 to 3months period. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of $3-15{\mu}m$. The micro structure revealed pore sizes of $1-3{\mu}m$, the crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. Bone tissue responses were evaluated by resonance frequency measurements that were undertaken 1 to 3months after insertion in the rabbit tibia. It was concluded that no statistical difference of RFA values was found between the groups, RFA gains after Imonth and 3months were calculated.

족근 관절 경비 인대 결합 손상 (Ankle Syndesmotic Injury)

  • 곽희철;권용욱
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.187-194
    • /
    • 2011
  • Ankle injuries may involve the distal tibiofibular syndesmosis and can be associated with a variable degree of trauma to the soft tissue and osseous structures that play an important role in ankle joint stability. Ankle syndesmotic injury may occur solely as a soft tissue injury or in association with variable ankle fractures. Ankle syndesmotic injury does not necessarily lead to ankle instability; however, the coexistence of deltoid ligament injury critically destabilizes the ankle joint. The prevalence of these injuries may be higher than previously reported. The diagnosis of syndesmotic injury as not always easy because isolated ankle sprains may be missed in the absence of a frank diastasis and syndesmotic instability may be unnoticed in the presence of bimalleolar ankle fractures. Controversies arise at almost every phase of treatment includings : type of fixation(screw size, type of implant), number of cortices required for fixation and of need for hardware removal. Regardless of controversies, the most important goal should be restore and maintain the normal tibiofibular relationship to allow for healing of the ligamentous structures of the syndesmosis.

척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가 (Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion)

  • 김윤혁;박원만;김경수;박형균;주증우;박경우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

The humeral suspension technique: a novel operation for deltoid paralysis

  • de Joode, Stijn GCJ;Walbeehm, Ralf;Schotanus, Martijn GM;van Nie, Ferry A;van Rhijn, Lodewijk W;Samijo, Steven K
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.240-243
    • /
    • 2022
  • Isolated deltoid paralysis is a rare pathology that can occur after axillary nerve injury due to shoulder trauma or infection. This condition leads to loss of deltoid function that can cause glenohumeral instability and inferior subluxation, resulting in rotator cuff muscle fatigue and pain. To establish dynamic glenohumeral stability, a novel technique was invented. Humeral suspension is achieved using a double button implant with non-resorbable high strength cords between the acromion and humeral head. This novel technique was used in two patients with isolated deltoid paralysis due to axillary nerve injury. The results indicate that the humeral suspension technique is a method that supports centralizing the humeral head and simultaneously dynamically stabilizes the glenohumeral joint. This approach yielded high patient satisfaction and reduced pain. Glenohumeral alignment was improved and remained intact 5 years postoperative. The humeral suspension technique is a promising surgical method for subluxated glenohumeral joint instability due to isolated deltoid paralysis.

Management of Intraoperative Acetabular Fractures in Total Hip Arthroplasty: A Current Concept Review

  • Christian Hipfl;Sebastian Hardt;Carsten Perka
    • Hip & pelvis
    • /
    • 제36권3호
    • /
    • pp.179-186
    • /
    • 2024
  • Intraoperative acetabular fractures (IAFs), a complication seldomly encountered in total hip arthroplasty, are typically a result of the impact of insertion of a cementless press-fit cup. Factors that contribute to the risk of these types of fractures include poor bone quality, highly sclerotic bone, and the use of a press-fit cup that is excessively large. The approach to management of these fractures is dependent on when they are identified. Immediate stabilization measures should be implemented for management of fractures detected during surgery. When fractures are detected postoperatively, the decision regarding conservative treatment is dependent on the stability of the implant and the specific fracture pattern. In the majority of cases, effective treatment of an acetabular fracture detected intraoperatively can be administered using a multi-hole revision cup along with anchoring screws in the various regions of the acetabulum. Selection of plate osteosynthesis of the posterior column is recommended when there is a large posterior wall fragment or pelvic discontinuity. In cases where anatomical dimensions allow, cup-cage reconstruction may offer a promising alternative to a combined hip procedure. The number of reports addressing the management of IAFs is limited. This review focuses on outlining the strategies that are currently available for management of this seldomly encountered complication.

티타늄 임플란트의 표면처리가 골유착에 미치는 영향에 관한 조직형태계측학적 연구 (A histomorphometric study on the effect of surface treatment on the osseointegration)

  • 최웅재;조인호
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.445-456
    • /
    • 2009
  • 연구목적: 임플란트를 이용한 수복의 임상적인 성공에 중요한 역할을 하는 초기 골유착의 향상을 위해 티타늄의 표면 거칠기 조절과 함께 생체활성도를 가진 표면으로 변화시키는 방법에 관한 연구가 이루어지고 있다. 표면 거칠기의 적절한 증가는 조골세포의 활동을 증가시키고 골과 임플란트의 접촉과 유지를 촉진시킨다고 보고되고 있고 또한 알칼리와 열처리를 통하여 생체 활성 표면을 얻을 수 있는 것으로 보고되고 있다. 이에 본 연구에서는 알칼리 및 열을 이용한 티타늄 표면 처리가 골유착에 어떤 영향을 미치는지 알아보고자 하였다. 연구재료 및 방법: 기계절삭된 임플란트를 대조군으로 하여 (1군), 5 M NaOH 용액에 처리한 임플란트를 대기 중에서 열처리한 군 (2군)과 진공에서 열처리한 군 (3군)으로 분류하였다. 알칼리와 열처리를 시행한 임플란트들의 표면 특성을 관찰하고 가토에 식립하여 치유 기간에 따라서 조직학적 및 조직형태계측학적으로 비교하고 EPMA (Electron Probe Micro Analyzer)를 이용하여 치유 기간 별 골성분의 변화를 분석하였다. 결과 및 결론: 대기 중에서 열처리한 2군이 통계적으로 유의하게 (P<.05) 증가된 표면 거칠기를 보였다. 이렇게 만들어진 임플란트를 가토에 식립하여 조직 형태계측학적 분석을 시행한 결과 골-임플란트 접촉율은 전반적으로 치유기간이 경과하면서 증가하는 것으로 나타났으며 2군과 3군에서 통계적 분석결과 치유기간 간에 유의한 차이가 관찰되었고 (P<.05), 골-임플란트 면적율 (BA) 또한 골 임플란트 접촉율과 비슷한 양상을 보였으며 통계적 분석결과 2군에서만 치유기간별로 통계적으로 유의한 차이가 관찰되었다 (P<.05). 치유 기간별로 임플란트 주변 골에서 칼륨 (K), 인 (P), 칼슘 (Ca), 티타늄 (Ti)의 분포를 EPMA로 보았을 때 빈도의 편향은 관찰되지 않았으며 2군과 3군에서 초기에 칼슘과 인이 증가되는 것이 관찰되었다. 이상의 결과로 볼 때 알칼리 및 대기 중에서 열처리로 표면 처리된 임플란트의 사용은 초기에 안정된 골유착에 도움을 주며 임플란트 식립 후 기능까지의 시간을 감소시킬 것으로 사료된다.

다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구 (Detorque values of abutment screws in a multiple implant-supported prosthesis)

  • 이주리;이동환;황재웅;최정한
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.280-286
    • /
    • 2010
  • 연구 목적: 본 연구는 다수의 임플란트에 의해 지지되는 보철물을, 두 가지 인상법에 의해 얻은 모형들에 연결한 후, 나사의 풀림 토크값을 측정하여 나사 결합부 안정성에 차이가 있는지를 알아보는데 그 목적이 있다. 연구 재료 및 방법: 네 개의 외부 육각 임플란트 (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB)에 직접 연결되는 임플란트 상부 구조물과, 이와 수동적 적합을 갖는 완전 무치악 하악주모형을 만들었다. 이 주모형에서 비연결 인상법으로 6회 인상을 채득하여 6개의 모형 (1군)을 제작하고, 아크릴릭 레진을 이용한 연결 인상법으로 6회 인상을 채득하여 6개의 모형 (2군)을 제작하여, 총 12개의 실험모형을 제작하였다. 각 실험모형에 상부 구조물을 지대주 나사 ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB)로 20 Ncm의 힘으로 조인 후 각 나사의 풀림 토크값을 총 2회 측정하였다. 두 군 간 나사의 풀림 토크값의 비교를 위한 통계분석은 반복측정을 고려하고 나사와 reading을 고정효과로, 모형을 랜덤효과로 포함하는 혼합모형 (mixed model)을 이용하여 유의수준 .05에서 실시하였다. 결과: 나사의 풀림 토크값의 평균은 7.9 Ncm (1군)과 8.1 Ncm (2군)이었으며, 4개 나사의 풀림 토크값 중 최소값인 최소 풀림 토크값의 평균은 6.1 Ncm (1군)과 6.5 Ncm (2군)이었다. 나사의 풀림 토크값은 두 군 간에 통계적으로 유의할 만한 차이가 없었고, 조인 순서와 위치가 서로 다른 4개의 나사 간의 풀림 토크값도 통계적으로 유의한 차이가 없었다. 최소 풀림 토크값도 두 군 간에 통계적으로 유의할 만한 차이가 없었다. 결론: 다수의 외부 육각 임플란트에 의해 지지되는 보철물에서, 나사의 풀림 토크값과 최소 풀림 토크값은 비연결 인상법과 연결 인상법에 의해 얻어진 모형 간에 차이가 없어, 나사 결합부 안정성에 차이가 없는 것으로 판단된다.