A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

완전 무치악 환자에서 나사-시멘트 보철물(SCP: screw-cement prosthesis)을 이용한 임플란트 보철 수복 증례 (Retrievable SCP (screw-cement prosthesis) implant-supported fixed partial dentures in a fully edentulous patient: a case report)

  • 김주현;윤보혁;장정은;허중보;정창모
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.318-323
    • /
    • 2012
  • 임플란트 보철물은 유지방법에 따라 크게 나사 유지형 보철물(screw-retained prosthesis)과 시멘트 유지형 보철물(cement-retained prosthesis)로 나눌 수 있으며, 이들 장점을 고려하여 만든 나사-시멘트 유지형 보철물(SCRP: screw and cement retained implant prosthesis)이있다. 나사-시멘트 유지형 보철물은 임플란트 지대주와 상부 보철물 사이의 시멘트 층이 보철물 제작 과정에서 발생하는 여러 오차를 보상하여 수동적 적합을 얻을 수 있으며, 임상 및 기공 과정이 간단한 장점과 더불어 임플란트 보철의 유지 관리를 위해 필수적인 탈 부착(retrievability)이 가능하다. 본 증례에서는 완전 무치악 환자를 대상으로 상, 하악에 각각 9, 8개의 임플란트(US II, OSSTEM, Seoul, Korea)를 식립하고 나사 구멍이 순측으로 향하는 부위는 시멘트 유지형, 다른 부위는 나사-시멘트 유지형태를 사용하여 복합형태의 나사-시멘트 보철물(SCP: screw-cement prosthesis)을 제작하였으며 3년 간의 정기 검사에서 기능과 심미적으로 만족할 만한 결과를 얻어 이를 보고하고자 한다.

수종 임플랜트 시스템에서의 회전력에 관한 연구 (A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM)

  • 문익훈;정재헌
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

시멘트 유지형 임플란트 보철물의 신개념 유지 방식: Fiber post의 설측 수평 삽입에 의한 유지력 보완 (A new retaining method of cement-retained restoration with linguo-horizontal insertion of fiber post)

  • 윤나리;이성복;이석원;안수진;박수정
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.71-78
    • /
    • 2017
  • 임플란트 보철물을 지대주 및 임플란트에 연결하는 방법은 크게 나사 유지방식과 시멘트 유지방식으로 나눌 수 있다. 나사 유지형의 장점은 탈착 가능성과 잔류 시멘트가 남지 않는다는 점이나 상대적으로 나사 풀림이나 파절의 비율이 시멘트 유지방식에 비해 높다는 단점이 있다. 반면 시멘트 유지형은 심미적이고 상대적으로 적은 비용으로 보철물을 제작할 수 있으나 탈착의 용이성이 불리하다는 단점이 있다. 이 두 가지의 장점을 조합한 방식으로 SCRP방식이 소개되었다. 그러나 역시 이상적인 임플란트 식립 위치를 전제로 한다. 이러한 여러 가지 보철 방식의 단점들을 해결하기 위하여 잔여 시멘트를 남기지 않으면서 연조직 염증을 예방할 수 있는 fiber post 유지형 보철 연결방식을 새롭게 소개하고자 한다.

EFFECT OF THE SURFACE MODIFICATIONS AND THE USE OF WASHER ON THE REVERSE TORQUE OF THE IMPLANT PROSTHETIC GOLD RETAINING SCREW

  • Lee, Jae-Hyuck;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.246-261
    • /
    • 2002
  • The screw loosening is one of the complications that happen frequently in dental implant prostheses. The purpose of this study was to evaluate the changes of reverse/loosening (opening) torque of the screw according to the surface modifications by sandblasting and 24K gold electroplating as well as to determine the possibility of the clinical use of a washer in dental implant. The reverse torque of 4 experimental conditions(control, sandblasted, use of washers, electroplasted) was measured by digital torque gauge (Model MGT50Z, Mark-10 Corp., 458 West John Street Hicksville, NY 11801 USA). Electronic torque controller (Nobel Biocare DEA 020) was used in fastening the gold screws into abutment replicas. Mixed Linear Model Analysis method was used for statistical analysis. To examine the changes of screw thread surface, microphotographs were taken by Olympus PME-3 metallurgic microscope (Olympus Optical Co. Ltd., Tokyo, Japan). Within the limitations of this study, the following results were drawn: 1. The surface modifications of the gold screws and the use of a washer have significantly affected the reverse torque value compared to the control group (P<0.01). 2. Sandblasting and electroplating treatments demonstrated significantly higher reverse torque value than that of control group. 3. The use of a washer may be one of the useful clinical methods that prevent the screw loosening. However, further studies are necessary for the material selection and design of the washer.

부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report)

  • 하승룡
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 완전무치악 환자한테 처음으로 시도되었던 임플란트 보철치료는 현재는 단일치아 상실된 경우까지 그 활용범위가 넓어졌으며, 임플란트 보철치료는 현대 치과에서는 거의 필수적인 치료방법으로 자리매김 하였다. 임플란트 보철물을 제작하는데 사용되는 재료도 초기에 비해 다양해졌는데, 그 중 하나가 고기능성 폴리머의 적용이다. 예전부터 의과에서 많이 사용되어 왔던 고기능성 폴리머를 치과에서도 시도하는 빈도가 점점 늘어나고 있다. 이에 고기능성 폴리머를 구치부 임플란트 지대주로 사용한 3가지 증례를 보고하고자 한다. 첫번째 증례는 하악 좌측 제2소구치가 상실된 부위에 PEKK 지대주 및 PFG 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 두번째 증례는 상실된 상악 좌측 제1대구치 부위에 PEKK 지대주 및 monolithic zirconia 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 마지막 증례는 상악 우측 제1,2 대구치 상실부위에 PEKK 지대주 및 splinted PFM 크라운(시멘트-나사-유지형)을 제작하여 장착하였다. 4년의 추적 관찰 결과 상기 환자 모두 심미적 및 기능적으로 만족스러운 결과를 얻었기에 증례를 보고하고자 한다.

임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 : Part II - 임플란트 유지나사 (Fracture Analysis of Implant Components using Scanning Electron Microscope : Part II - Implant Retaining Screw)

  • 임광길;김대곤;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.373-388
    • /
    • 2010
  • 보철물의 실패는 파절로 인해 다수 발생하게 되지만 파절 발생시 그 원인을 파악하는 것은 어렵다. 보철물의 실패를 예방하고 예후를 예측하기 위해 보철물의 원인을 분석하는 것이 중요하며, 원인을 밝히기 위해 파절면 분석을 시행하게 된다. 파절면 분석은 파절면 뿐 아니라 주위 환경(응력 상황)에 대한 분석이 동반되며, 이를 이용하여 균열 진행, 파절 양상, 파절 원인 등을 파악하게 된다. 이 연구의 목적은 임상적으로 기능 시 파절된 임플란트 유지나사의 파절면 분석을 시행하여 파절 기전 및 파절 원인(하중 양상)을 밝히는 것이다. 파절된 임플란트 유지나사는 3년간 강릉-원주 대학교에 임플란트 유지나사의 파절을 주소로 내원한 환자를 대상으로 수집하였다. 먼저 임상 및 방사선 사진 분석을 시행하였으며, 시편 세척 과정을 거쳐 주사 전자 현미경을 이용한 파절면 분석을 시행하였다. 임플란트 파절면 분석 시 피로 줄무늬, 톱니바퀴 모양, 벽개 파절, 딤플 파절 등의 파절 지표를 통해 제작 금속, 파절 시 하중상태에 따른 각기 다른 파절 양상을 관찰할 수 있었다.

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과 (Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws)

  • 류승범;허성주;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.103-109
    • /
    • 2020
  • 목적: 본 연구의 목적은 임플란트 지대주 나사에 혐기성 나사 고정제의 적용 유무와 나사 종류에 따른 풀림 토크 값의 차이를 평가하는 것이다. 재료 및 방법: 외부 육각형 임플란트 고정체를 사용하였고, 동일한 제조사의 지대주와 지대주 나사가 사용되었다. 지대주 나사는 두 종류로 티타늄 재질의 나사(티타늄 나사)와 텅스텐 카바이드 코팅된 나사(Ebony 나사)가 사용되었다. 티타늄 나사에 아무 처리하지 않은 군(TI군)과 티타늄 나사에 나사 고정제를 사용한 군(TI_AS군), Ebony 나사에 아무 처리하지 않은 군(EB군)과 Ebony 나사에 나사 고정제를 사용한 군(EB_AS군)에 대해 실험을 진행하였다. 총 4가지 군에서 각 10개씩의 임플란트 고정체-지대주 복합체가 사용되었다. 디지털 토크 측정 장비를 사용하여 풀림 토크 값을 측정한 뒤 통계 처리하여 각 군별 비교하였다. 정규성 분포를 만족하여 Two-way ANOVA test (α = .05)를 이용하여 통계 분석하였다. 결과: 각 군에 대한 결과를 살펴보면 TI 군은 20.3 ± 1.6 N.cm, TI_AS 군에서 32.4 ± 6.7 N.cm, EB 군은 20.2 ± 1.5 N.cm, EB_AS 군에서 30.4 ± 4.5 N.cm의 풀림 토크 값을 나타냈다. 결론: 혐기성 나사 고정제를 사용한 경우 티타늄 나사와 ebony 나사 모두에서 고정제를 사용하지 않은 경우 보다 풀림 토크 값이 높게 나타났다. 하지만 두 나사 군 간의 차이는 존재하지 않았다.