• Title/Summary/Keyword: implant position

Search Result 283, Processing Time 0.027 seconds

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Concept and application of implant connection systems: Part I. Placement and restoration of internal conical connection implant (임플란트 연결부의 개념과 적용: Part 1. 원추형 내부연결 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.211-221
    • /
    • 2020
  • The typical biomechanical properties of an internal conical connection (ICC) are axial displacement and loss of preload. The axial displacement of an ICC without a vertical stop can cause the loss of preload and a lowered occlusion. The stress of an ICC is concentrated on the contact interface of the abutment and not on the screw, and during placement, it is important to choose a wider coronal wall thickness as much as possible. The ICC should also be placed below the level of the bone crest. During the restoration of an ICC, care should be taken to ensure an appropriate abutment shape and an accurate connection. To get the best clinical results, it is important to select its wall thickness and place it in the appropriate position to restore it adequately.

The effect of maintenance period of non-resorbable membrane on bone regeneration in rabbit calvarial defects (가토 두개골 결손부에서 비흡수성 차단막의 유지 기간에 따른 골조직 형성효과)

  • Jung, Min-Gu;Jang, Hyun-Seon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.543-551
    • /
    • 2007
  • When clinicians faced with an insufficient volume of supporting bone on ideally esthetic and bio-mechanical position for dental implantation, guided bone regeneration(GBR) was indicated. Although GBR has wide application at clinic, proper time of membrane removal remains qustionable in using non-resorbable membrane, such as non-expanded polytetrafluoroethylene(PTFE), The aim of this study was to compare the effect of maintenance period of PTFE membrane on bone regeneration in rabbit calvarial defects. Eight adult New Zealand white female rabbits were used in this study. Four defects were surgically made in their calvaria. Using a trephine bur, 4 'through and through' defects were created and classified into 3 groups, which were consisted of control group(no graft), experimental group 1(autogenous bone)and experimental group 2(deproteinized bovine bone; $OCS-B^{(R)}$). The defects were covered with PTFE membrane($Cytoplast^{(R)}$). Membranes were removed after 1, 2, 4 and 8 weeks post-GBR procedure in 2 rabbits repectively, All rabbits were sacrificed after 8 week post-GBR procedure. Specimens were harvested and observed histologically. The results were as follow; 1) The use of graft material and membrane was necessary in GBR procedure. 2) When PTFE membranes were removed early, the most favorable bone regeneration was revealed in experimental group T, followed by experimental group II and control group. 3) On GBR, it is recommended that membrane should maintain for 4 weeks with autogenous graft. As well, the use of xenograft need longer maintenance period than autogenous bone. Further evaluations will be needed, such as histomorphologic research, more species and different kinds of graft materials. And on the basis of these studies, clinical researches would be required.

Comparative inorganic analysis of the mesiodens and the 3rd molar as the autogenous tooth graft materials

  • Lee, Sung-Suk;Kim, Su-Gwan;Oh, Ji-Su;You, Jae-Seek;Kim, Won-Gi;Yang, Jung-Eun;Lim, Hyoung-Sup
    • The Journal of the Korean dental association
    • /
    • v.55 no.2
    • /
    • pp.128-138
    • /
    • 2017
  • Objective: The aim is to evaluate the potential of the mesiodens through the comparative inorganic analysis of 3rd molar teeth prior to clinical study. Material and methods: The extracted mesiodens and the 3rd molar teeth were prepared. The teeth are prepared as in the process of the autogenous tooth bone graft. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) analysis was performed for inorganic analysis. Results: Rough and porous surfaces were observed in all materials in SEM analysis. Ca/P ratio of mesiodens was 1.55 and the 3rd molar was 1.22 in EDS analysis. XRD analysis shows that the 3 main peaks position were similar. This means that the graft materials are very similar to that of the crystallinity. Conclusions: The mesiodens and the 3rd molar teeth are very similar to the inorganic component. These results provide the reasonable rationale that mesiodens can be used as autogenous tooth bone graft in a clinic.

  • PDF

Comparison of treatment effects between four premolar extraction and total arch distalization using the modified C-palatal plate

  • Jo, Sung Youn;Bayome, Mohamed;Park, Justyn;Lim, Hee Jin;Kook, Yoon-Ah;Han, Seong Ho
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.224-235
    • /
    • 2018
  • Objective: The purpose of this study was to compare the skeletal, dental, and soft-tissue treatment effects of nonextraction therapy using the modified C-palatal plate (MCPP) to those of premolar extraction (PE) treatment in adult patients with Class II malocclusion. Methods: Pretreatment and posttreatment lateral cephalographs of 40 adult patients with Class II malocclusion were retrospectively analyzed. The MCPP group comprised 20 patients treated with total arch distalization of the maxillary arch while the PE group comprised 20 patients treated with four PE. Fifty-eight linear and angular measurements were analyzed to assess the changes before and after treatment. Descriptive statistics, paired t-test, and multivariate analysis of variance were performed to evaluate the treatment effects within and between the two groups. Results: The MCPP group presented 3.4 mm of retraction, 1.0 mm of extrusion, and $7.3^{\circ}$ lingual inclination of the maxillary central incisor. In comparison, the PE group displayed greater amount of maxillary central incisor retraction and retroclination, mandibular incisor retraction, and upper lip retraction (5.3 mm, $14.8^{\circ}$, 5.1 mm, and 2.0 mm, respectively; p < 0.001 for all). In addition, the MCPP group showed 4.0 mm of distalization and 1.3 mm of intrusion with $2.9^{\circ}$ distal tipping of the maxillary first molars. Conclusions: These findings suggest the MCPP is an effective distalization appliance in the maxillary arch. The amount of incisor retraction, however, was significantly higher in the PE group. Therefore, four PE may be recommended when greater improvement of incisor position and soft-tissue profile is required.

Inlay Grafting for the Treatment of the Posterior Comminuted Fracture of Medial Orbital Wall (Inlay법을 이용한 안와 내벽 골절의 교정)

  • Lim, Jong-Hyo;Kim, Tae-Gon;Lee, Jun-Ho;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.55-60
    • /
    • 2009
  • Purpose: For blowout fracture of the medial orbital wall, the goals of treatment are complete reduction of the herniated soft tissue and anatomic reconstruction of the wall without surgical complications. Surgeons frequently worry about damage to the optic nerve from the dissection, when the part over the posterior ethmoidal foramen was fractured. The authors performed small incision and inlay grafting for reconstruction of medial orbital wall fracture. Methods: Between January 2007 and April 2008, 15 out of 32 patients were included in an analysing the outcome of corrected medial orbital wall fracture. In 15 patients of posterior comminuted fracture of medial orbital wall, insertion of porous polyethylene($Medpor^{(R)}$ channel implant, Porex, USA) to ethmoidal sinus was performed in multiple layer, through the transconjunctival approach (inlay grafting). Results: In all cases, the orbital bone volume was reconstructed in its normal anatomical position. The associated ocular problems disappeared except for mild enophthalmos in 2 patients and there were no surgical complications associated with inlay grafting. Conclusion: The advantage of inlay grafting include anatomical reconstruction of the orbital wall; the avoidance of optic nerve injury; the simplicity of the procedure; and consequently, the absence of surgery-related complications. This technique is presented as one of the preferred treatments for posterior comminuted fracture of medial orbital wall.

RIGID FIXATION AND SPACE MAINTENANCE BY TITANIUM MESH FOR RECONSTRUCTION OF THE PREMAXILLA (상악골 전방 결손부 재건 시 견고 고정과 공간 유지로 사용된 타이타니움 메쉬의 임상 예)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Koh, Myoung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2005
  • Reconstruction of defect in the anterior part of the maxilla to enable implant placement or prothesis is a complicated treatment due to the anatomical position and lack of soft tissues. Two cases are presented in which autogenous iliac PMCB(particulate marrow and cancellous bone) with titanium mesh were used for premaxilla reconstruction and alveolar bone repair of the anterior maxillas prior to denture and implants fixation respectively. Cancellous bone from the anterior iliac crest was compressed and placed against a titanium mesh fixed to the bone of palate in a patient with severe defect of the anterior maxilla. There were no problem in the healing, and the anterior maxillas of two patients had increased height and width during the initial healing and remodeling. The clinical reports describe the use of titanium mesh for reconstruction of premaxilla. Autogenous bone grafts were harvested from the iliac crest and were loaded on a titanium mesh that were left in the patient's maxilla for 6 months before they were removed respectively. The radiographic analysis demonstrated that a 10mm vertical ridge augmentation had been achieved. In guided bone regeneration, the quantity of bone regenerated under the barrier has been demonstrated to be directly related to the amount of the space under the membrane. This space can diminish as a result of membrane collapse. To avoid this problem which involved the use of a titanium mesh barrier to protect the regenerating tissues and to achieve a rigid fixation of the bone segments, were used in association with autologous bone in 2 cases. The aim of this study was to evaluate the capability of a configured titanium mesh to serve as a mechanical and biologic device for restoring a vertically defected premaxilla.

Tomographic and histometric analysis of autogenous bone block and synthetic hydroxyapatite block grafts without rigid fixation on rabbit calvaria

  • Bae, Soo-Yong;Park, Jung-Chul;Shin, Hyun-Seung;Lee, Yong-Keun;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.251-258
    • /
    • 2014
  • Purpose: The preferred material for bone augmentation beyond the envelope of skeletal bone is the bone block graft, due to its dimensional stability. We evaluated the necessity of rigid fixation for the bone block graft, and compared the bone regeneration and volume maintenance associated with grafting using a synthetic hydroxyapatite block (HAB) and an autogenous bone block (ABB) without rigid fixation on rabbit calvaria over two different periods. Methods: Cylinder-shaped synthetic HAB and ABB were positioned without fixation on the rabbit calvarium (n=16). The animals were sacrificed at 4 or 8 weeks postoperatively, and the grafted materials were analyzed at each healing period using microcomputed tomography and histologic evaluation. Results: Integration of the graft and the recipient bed was observed in all specimens, although minor dislocation of the graft materials from the original position was evident in some specimens (six ABB and ten HAB samples). A tendency toward progressive bone resorption was observed in the grafted ABB but not in the grafted HAB, which maintained an intact appearance. In the HAB group, the area of new bone increased between 4 and 8 weeks postoperatively, but the difference was not statistically significant. Conclusions: The nonfixed HAB was successfully integrated into the recipient bed after both healing periods in the rabbit calvaria. In spite of limited bone formation activity in comparison to ABB, HAB may be a favorable substitute osteoconductive bone material.

PERIODONTAL REGENERATION FOLLOWING RECONSTRUCTIVE SURGERY INCLUDING TOPICAL APPLICATION OF TETRACYCLINE IN DOGS (테트라싸이클린이 치주결체조직의 재부착에 미치는 효과)

  • Choi, Sang-Mook;Han, Soo-Boo;Koo, Jea-Seung;Kang, Yun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.203-218
    • /
    • 1993
  • This study was designed to examine the effect of tetracycline application to the planed periodontal surgery of the experimentally induced periodontal disease in dogs. Modified Widman flap surgery was done and aqueous tetracycline (1%) was applied to the root surface for 5min, after which the wound was rinsed with saline, and flaps were coronally repositioned. Root surface ntoches were used as reference points. The animals were sacrificed 1 week, 2 weeks, 4 weeks, and 8 weeks after surgery, and block sections of tooth and surround tissue were processed for conventional light and electron microscopy. The results were as follows : 1. A more coronal position of junctional epithelium was observed in the area treated with tetracycline. 2. In the most of the tetracycline - treated teeth, the new collagen fibrils of connective tissue were oriented vertical/or oblique and parallel to the root surface. The vertical or oblique fibers were inserted into the denuded dentin matrix and contacted with exposed dentin collagen fibrils. 3. In the tetracycline - treated root, new cementum apposition, most of acellular extrinsic fiber cementum, was seen with bundles of oriented collagen fibrils incoporating into the cementum. 4. In the control and tetracyclin - treated teeth, bone resorption was observed at the alveolar crest in the 1 week groups.

  • PDF