• Title/Summary/Keyword: implant failure

Search Result 302, Processing Time 0.023 seconds

EFFECT ON THE OSTEOGENESIS OF DENTAL IMPLANTS AFTER HORIZONTAL DISTRACTION OSTEOGENESIS WITH NITRIFIED DISTRACTOR (질화 표면처리된 신장기를 이용한 수평적 치조골신장술 후 임플란트 식립시 골유착 효과에 관한 연구)

  • Park, Chul-Min;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Oh, Ji-Su;Baik, Sung-Mun;Lim, Sung-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2008
  • This study evaluated whether there is a difference between a conventional titanium distraction device and a TiN-coated device in terms of implant osseointegration after horizontal distraction osteogenesis in narrow alveolar bone. Four adult mongrel dogs, each weighing $9{\sim}10kg$, were used in this study. The lower premolars were extracted and horizontal distraction was performed with conventional titanium distraction devices (group 1) or TiN-coated devices (group 2). After an 8-week consolidation period, the implants were installed, and the dogs were sacrificed after another 8 weeks. The osseointegration around the implants was evaluated histomorphologically. There was one failure in experimental group 1 because of fracture of the device. Direct bone contact was achieved and there were no significant differences between the control group and experimental groups 1 and 2 in terms of osseointegration around the implants at 8 weeks. In summary, intraoral distraction osteogenesis is a good option for augmenting severely atrophied alveolar ridges, and the TiN-coated device may be useful because of its advantages, which include surface hardness, corrosion resistance, and reduced bacteria.

A clinical study of iliac bone graft using subperiosteal tunneling method for alveolar ridge augmentation (심하게 흡수된 치조제의 증강을 위한 골막하 터널링기법을 이용한 장골이식술에 대한 임상연구)

  • Park, Soong;Jung, Jun-Ho;Kim, Yeo-Gab;Kwon, Yong-Dae;Choi, Byung-Joon;Ohe, Joo-Young;Lee, Baek-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.427-433
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate the efficacy of the subperiosteal tunneling technique with iliac block bone graft for bone augmentation in an edentulous alveolar ridge. Patients and Methods: Total of 8 sites in 7 patients were included in this study. The bone height was evaluated by CBCT preoperatively and 4 months after operation. Total of 11 implants were inserted and evaluated clinically and radiographically. Results: Mean value of the increased bone height was 6.29 mm and no implant failure was observed. There were no complications such as soft tissue dehiscence, exposure of the grafted bone and infection. Conclusion: We have achieved excellent clinical outcomes by this technique, so we concluded that it is useful for augmentation of severely deficient alveolar ridge.

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Short Segment Fixation for Thoracolumbar Burst Fracture Accompanying Osteopenia : A Comparative Study

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Lee, Sung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • Objective : The purpose of this study was to compare the results of three types of short segment screw fixation for thoracolumbar burst fracture accompanying osteopenia. Methods : The records of 70 patients who underwent short segment screw fixation for a thoracolumbar burst fracture accompanying osteopenia (-2.5< mean T score by bone mineral densitometry <-1.0) from January 2005 to January 2008 were reviewed. Patients were divided into three groups based on whether or not bone fusion and bone cement augmentation procedure 1) Group I (n=26) : short segment fixation with posterolateral bone fusion; 2) Group II (n=23) : bone cement augmented short segment fixation with posterolateral bone fusion; 3) Group III (n=21) : bone cement augmented, short segment percutaneous screw fixation without bone fusion. Clinical outcomes were assessed using a visual analogue scale and modified MacNab's criteria. Radiological findings, including kyphotic angle and vertebral height, and procedure-related complications, such as screw loosening or pull-out, were analyzed. Results : No significant difference in radiographic or clinical outcomes was noted between patients managed using the three different techniques at last follow up. However, Group I showed more correction loss of kyphotic deformities and vertebral height loss at final follow-up, and Group I had higher screw loosening and implant failure rates than Group II or III. Conclusion : Bone cement augmented procedure can be an efficient and safe surgical techniques in terms of achieving better outcomes with minimal complications for thoracolumbar burst fracture accompanying osteopenia.

A 3D-printing Bone Model for Surgical Planning of Total Hip Replacement after Failed Triple Pelvic Osteotomy

  • Han, Kyungjin;Park, Jiyoung;Yoon, Jangwon;Lee, Young-Won;Choi, Ho-Jung;Jeong, SeongMok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.463-466
    • /
    • 2017
  • A 3-year-old, 26 kg, castrated male Chow Chow was presented for assessment of weight-bearing lameness of the left hind limb. The patient had a history of triple pelvic osteotomy on the left side to correct hip dysplasia 2 years prior to his presentation of clinical signs and underwent total hip replacement on the right coxofemoral joint 1 year later. Upon physical examination, pain and crepitus were noted on the left hip joint during extension. Radiological examination revealed coxofemoral joint subluxation and moderate degenerative bone changes on the left hip joint and pelvic axis, which relates to acetabular angles that were changed after triple pelvic osteotomy (TPO). Preoperative computed tomography was used for 3-dimensional printing to establish an accurate surgical plan. The changed angles of the acetabulum after TPO were evaluated, and rehearsal surgery was performed using a 3-demensional printing bone model. Three months after the THR surgery, the function of the affected limb had improved, with no lameness. Complications, such as luxation and implant failure, were not observed until 6 months after the operation. Accurate evaluation of acetabulum angles and rehearsal surgery using a 3D-printed bone model is effective for total hip replacement after unsuccessful TPO.

Charlson comorbidity index as a predictor of periodontal disease in elderly participants

  • Lee, Jae-Hong;Choi, Jung-Kyu;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.92-102
    • /
    • 2018
  • Purpose: This study investigated the validity of the Charlson comorbidity index (CCI) as a predictor of periodontal disease (PD) over a 12-year period. Methods: Nationwide representative samples of 149,785 adults aged ${\geq}60$ years with PD (International Classification of Disease, 10th revision [ICD-10], K052-K056) were derived from the National Health Insurance Service-Elderly Cohort during 2002-2013. The degree of comorbidity was measured using the CCI (grade 0-6), including 17 diseases weighted on the basis of their association with mortality, and data were analyzed using multivariate Cox proportional-hazards regression in order to investigate the associations of comorbid diseases (CDs) with PD. Results: The multivariate Cox regression analysis with adjustment for sociodemographic factors (sex, age, household income, insurance status, residence area, and health status) and CDs (acute myocardial infarction, congestive heart failure, peripheral vascular disease, cerebral vascular accident, dementia, pulmonary disease, connective tissue disorders, peptic ulcer, liver disease, diabetes, diabetes complications, paraplegia, renal disease, cancer, metastatic cancer, severe liver disease, and human immunodeficiency virus [HIV]) showed that the CCI in elderly comorbid participants was significantly and positively correlated with the presence of PD (grade 1: hazard ratio [HR], 1.11; P<0.001; grade ${\geq}2$: HR, 1.12, P<0.001). Conclusions: We demonstrated that a higher CCI was a significant predictor of greater risk for PD in the South Korean elderly population.

Recipient Vessel Selection in Immediate Breast Reconstruction with Free Abdominal Tissue Transfer after Nipple-Sparing Mastectomy

  • Yang, Sung-Jun;Eom, Jin-Sup;Lee, Taik-Jong;Ahn, Sei-Hyun;Son, Byung-Ho
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.216-221
    • /
    • 2012
  • Background : Nipple-sparing mastectomy (NSM) is gaining popularity due to its superior aesthetic results. When reconstructing the breast with free abdominal tissue transfer, we must readdress the recipient vessel, because NSM can cause difficulty in access to the chest vessel. Methods : Between June 2006 and March 2011, a total of 92 women underwent NSM with free abdominal tissue transfer. A lateral oblique incision was used for the nipple-sparing mastectomy. For recipient vessels, the internal mammary vessels were chosen if the mastectomy flap did not block access to the vessels. If it did, the thoracodorsal vessels were used. Age, degree of breast ptosis, weight of the mastectomy specimen, and related complications of the internal mammary vessel group and the thoracodorsal vessel group were compared. Results : Thoracodorsal vessels were used as recipient vessels in 59 cases, and internal mammary vessels in 33 cases including 4 cases with perforators of the internal mammary vessels. Breast reconstruction was successful in all cases except one case involving a total flap failure, which was replaced by a silicone gel implant. The internal mammary group and the thoracodorsal group were similar in terms of age, height, breast weight, and degree of ptosis. The flap related complications such as flap loss and take-back operation rates were not significantly different between the two groups. The rate of nipple necrosis was higher in the internal mammary group. Conclusions : The thoracodorsal vessels could produce comparable outcomes in breast reconstruction after nipple-sparing mastectomies. If access to internal mammary vessels is difficult, the thoracodorsal vessel can be a better choice.

Secondary Breast Reconstruction (이차 유방 재건술)

  • Ahn, Hee Chang;Ahn, Yong Su;Kim, Youn Hwan;Choi, Seung Suk
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.761-766
    • /
    • 2009
  • Purpose: Secondary breast reconstruction is defined as a whole reconstructive procedure to correct complications and to improve the aesthetics when a patient is dissatisfied with her initial reconstruction. We would like to present these particular procedures on previously failed breast reconstruction with analysis of unsatisfactory results. Methods: From June 2002 to August 2008, we performed secondary breast reconstructions for 10 patients with failed breasts. Six patients with implant failure underwent secondary breast reconstructions using free TRAM flaps after the removal of implants. Two patients with partial loss of pedicled TRAM flaps underwent secondary breast reconstruction using Latissimus Dorsi flaps. Two patients with 1 total loss of free TRAM flap and 1 extensive fat necrosis underwent secondary breast reconstruction using implants. Results: The average age of the patients were 36.4 years (26 ~ 47 years). All flaps survived completely and had relatively good aesthetic results in free TRAM cases. There was breast asymmetry in one patient using cohesive gell implants in total loss of previously free TRAM patient, which was corrected by exchanging the implants and placing dermofat grafts. Conclusion: Secondary breast reconstruction differs from primary procedures in several aspects; there are changes in the anatomy and tissue environment of the breasts, and various limitations in choosing reconstruction methods. In addition, the patients may be uncomfortable with previous complication. It is important to consider various factors before deciding to undergo a secondary breast reconstruction carefully with informed consent.

Treatment of Two-Part Fracture of Humerus Neck Using T Plate Fixation (상완골 경부 이분 골절에서 T형 금속판을 이용한 치료)

  • Nam, Il-Hyun;Ahn, Gil-Yeong;Yun, Ho-Hyun;Kim, Jae-Cheol;Moon, Gi-Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.34-41
    • /
    • 2006
  • Purpose: This study is to analyze the result and complications of internal fixation with T-plate for two-part fracture of the neck of the humerus. Materials and Methods: The clinical results of fourteen patients who had been performed with this method mentioned above were reviewed. Their average age was 49.6. Postoperative mean follow up period was 24.1 months. Radiological evaluation was done by Kronberg's and shoulder function by Neer's. Results: By Kronberg evaluation, nine cases were good, two cases acceptable and three cases poor. By Neer's, mean score of shoulder function was 77.6 and 4 cases were excellent, one satisfactory, five unsatisfactory and four failure. The complications were the sfiff shoulder, loss of reduction and avascular necrosis of humeral head. Conclusion: In this study, there were differences according to the age. And we obtained an unsatisfactory result in patients over 50 years old. We consider that in patients over 50 years old, the differences were due to the muscle weakness through wide surgical approaches, postoperative implant loosening or the stiffness caused by poor rehabilitation.