• Title/Summary/Keyword: implant direction

검색결과 126건 처리시간 0.027초

A simple approach to preserve keratinized mucosa around implants using a pre-fabricated implant-retained stent: a report of two cases

  • Park, Jung-Chul;Yang, Ki-Bin;Choi, You-Na;Kim, Yong-Tae;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제40권4호
    • /
    • pp.194-200
    • /
    • 2010
  • Purpose: There is no consensus regarding the relationship between the width of keratinized mucosa and the health of periimplant tissues, but clinicians prefer to provide enough keratinized mucosa around dental implants for long-term implant maintenance. An apically positioned flap during second stage implant surgery is the chosen method of widening the keratinized zone in simple procedures. However, the routine suture techniques used with this method tend to apply tension over the provisional abutments and decrease pre-existing keratinized mucosa. To overcome this shortcoming, a pre-fabricated implant-retained stent was designed to apply vertical pressure on the labial flap and stabilize it in a bucco-apical direction to create a wide keratinized mucous zone. Methods: During second stage implant surgery, an apically displaced, partial thickness flap with a lingualized incision was retracted. A pre-fabricated stent was clipped over the abutments after connecting to the provisional abutment. Vertical pressure was applied to displace the labial flap. No suture was required and the stent was removed after 10 days. Results: A clinically relevant amount of keratinized mucosa was achieved around the dental implants. Buccally displaced keratinized mucosa was firmly attached to the underlying periosteum. A slight shrinkage of the keratinized zone was noted after the healing period in one patient, but no discomfort during oral hygiene was reported. Clinically healthy gingiva with enough keratinized mucosa was achieved in both patients. Conclusions: The proposed technique is a simple and time-effective technique for preserving and providing keratinized tissue around dental implants.

2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석 (Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type)

  • 변욱;정다운;한인혜;김성량;이창희
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.259-271
    • /
    • 2013
  • 임플란트 고정체-지대주 결합구조체의 형태에 따른 교합부하의 반응이 다양하여 본 연구에서는 하중위치 및 결합구조체 접촉 비율에 따라 3단 계단형 결합구조체와 경사형에서 어떠한 차이가 있는 지를 3차원 유한요소분석을 시행하였다. 2종의 임플란트-지대주 결합 구조체에 연결된 상부 치관을 제작하여 각 치관에 설정된 하중위치에 200 N의 하중을 부여하였다. 임플란트 중심 부위에서 하중조건이 멀어질수록 피질골정에 가해지는 응력이 증가되기에 하중조건은 응력발생에 영향을 미치는 주요 요소이며 다음으로 결합구조형태에도 영향을 받았다. 또한 수직 하중에 비해 빗금 경사 하중이 부여된 경우 계단형은 경사형에 비해 유리한 응력 분포를 보였다. 그리고 지대주 결합구조체가 고정체의 내벽에 대해 접촉이 많아 질수록 골질에 대한 응력분산이 유리한 것으로 나타났다. 결론적으로 고정체 폭경에서 벗어난 빗김 수직 및 경사 하중은 결합구조체의 종류와 관계없이 피질골정에 응력을 집중시키므로 저작기능시 교합접촉면을 고정체의 폭경 내에 위치하도록 하는 것이 생체역학적으로 바람직 할 것으로 사료되었다.

디지털 기법을 활용한 치과의사, 기공사, 그리고 환자 간의 효과적인 소통을 통한 전치부 임플란트의 진단 및 심미수복 증례 (Usage of digital technique to facilitate communication between dentist, dental lab technician, and patients in diagnosis and restoration for maxillary anterior implant: a case report)

  • 방혜민;장우형;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.42-51
    • /
    • 2022
  • 상악 전치부 임플란트 같이 심미성이 요구되는 부위의 보철수복은 임플란트 몸체의 식립각도에 영향을 많이 받는다. 순측으로 식립된 임플란트의 각도 때문에, 비심미적인 보철물의 결과가 예상되는 경우 치료에 앞서 환자와 임플란트 보철수복의 한계점을 논의하는 것은 매우 중요하다. 환자에게 치료의 한계점을 시각화하여 보여주기 위해 얼굴스캔 데이터와, CT 파일, 그리고 구내스캔을 중첩하여 디지털진단왁스업을 시행하여 환자에게 제시하였다. 환자는 순측으로 돌출된 보철물의 디자인에 불만족하였다. 환자의 의견을 반영하기 위해 3D 데이터를 이용하여 사고로 인해 이미 근관치료된 인접치를 포함한 새로운 디자인을 제시하고, 기공실팀과 함께 환자의 의견이 반영된 보철물을 제작하였다. 환자는 자신의 의견이 반영된 보철물에 심미적 및 기능적으로 만족하였다.

실크 피브로인 나노 차폐막(나노가이드-에스)을 이용한 치조골 유도재생능력에 관한 비교 연구 (A comparative study for guided bone regeneration of silk fibroin nanomembrane(NanoGide-$S^{TM}$))

  • 한대현;홍기석;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.475-482
    • /
    • 2008
  • Purpose: To evaluate the safety and efficiency of bone regenerative abilities of silk fibroin nanomembrane(Nanoguide-S) Material and Methods: The objects were 38 patients who had large defect at extraction sockets caused by chronic periodontitis and silk fibroin nano matrix were used on experimental group(N=19) and PLA/PLGA matrix were used on control group(N=19). The width, height, and length by crown-apical direction(socket depth) of defects were measured with the occlusal plane as a reference plane, and tooth axis direction, perpendicular to tooth axis direction were measured on radiographs at 3 months pre-operative, 3 months post-operative. Result: Tissue response to silk fibroin nano matrix and Biomesh were clinically satisfactory and complications such as swelling, exudation, ulceration and vesicles were not found except the ordinary discomfort of operated portion. 3 months later, the width, height, and length by crown-apical direction (socket depth) of defects were clinically improved in both groups with no significant difference. 3 months later radiolucency of tooth axis direction and perpendicular to tooth axis direction were all increased in both groups with no significant difference. Conclusion: By these results biodegradadable silk fibroin nano matrix was efficient in GBR on alveolar bone resorption caused by periodontitis compared to Biomesh.

인공 체액 조건에서 임플랜트용 티타늄 소재의 부식 특성 (Corrosion Behavior of Titanium for Implant in Simulated Body Fluids)

  • 이중배;최기열
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.110-118
    • /
    • 2004
  • The corrosion of pure titanium (CP- Ti Grade 2) and titanium alloy (Ti6Al4V ELI) were studied under various conditions of simulated body fluids. The static immersion test and the electrochemical test were performed in accordance with ISO 10271 : 2001. For the electrochemical test, the open circuit potential was monitored as a function of time, and the cyclic polarization curve was recorded. The corrosion resistance was evaluated from the values of corrosion potential, passivation current density, breakdown potential, and the shape of hysteresis etc. The effects of alloy type, surface condition, temperature, oxygen, and constituents in the fluids such as acid, chloride were estimated. Both specimens had extremely low dissolution rate in the static immersion test. They showed strong passivation characteristics in the electrochemical test. They maintained negligible current density throughout the wide anodic potential range. The passive layer was not broken up to 2.0 V (vs. SCE). The hysteresis and the shift of passivation potential toward the anodic direction was observed during the reversed scan. The passivation process appeared to be accelerated by oxygen in air or that dissolved in the fluids. The passivation also proceeded without oxygen by the reaction of constituents in the fluids. Acid or chloride in the fluids, specially later weakened the passive layer, and then induced higher passivation current density and less shift of passivation potential in the reversed scan. CP-Ti Grade 2 was more reactive than Ti6Al4V ELI in the fluids containing acid or chloride, but thicker layer produced on its surface provided higher corrosion resistance.

Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study

  • Mai, Hai Yen;Lee, Du-Hyeong
    • Journal of Korean Dental Science
    • /
    • 제13권1호
    • /
    • pp.28-34
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data. Materials and Methods: Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal-Wallis test and a post hoc Mann-Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05. Result: Overall discrepancy values ranged from 0.08 to 0.30 ㎛. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064). Conclusion: The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.

임플란트 식립을 위한 수술 가이드의 사용 (The use of surgical guide stent for implant placement)

  • 이지연;윤지영;오남식
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.366-375
    • /
    • 2014
  • 임플란트 식립 시 수술 가이드는 치료계획 수립 및 진단 뿐 아니라 식립 위치 및 각도를 조절하는데 도움을 준다. 수술 가이드는 식립 위치만 보여 주는 디자인(Nonlimiting design), 식립 위치와 각도를 보여주는 디자인(Partially limiting design), 식립 위치와 각도 및 깊이까지 보여주는 디자인(Completely limiting design)으로 나뉜다. 식립 위치와 각도를 보여주는 디자인은 제작이 비교적 간단하고 비용이 적게 드는 반면 식립 위치와 각도 및 깊이까지 보여주는 디자인보다 수술 정확성이 떨어진다는 단점을 가진다. 식립 위치와 각도 및 깊이까지 보여주는 디자인은 해부학적으로 정확하고 보철적, 생역학적 관점에서 최적화 된 치료를 할 수 있으며 심미적, 기능적으로 술 후 불편감을 최소화 해줄 수 있다. 본 논문에서는 다양한 수술 가이드에 대하여 문헌을 통해 고찰해보고 이를 임상에 적용한 증례를 살펴보고자 한다.

Hydrothermal Synthesis of $TiO_2$ Nanowire Array for Osteoblast Adhesion

  • Yun, Young-Sik;Kang, Eun-Hye;Hong, Min-Eui;Yun, In-Sik;Kim, Yong-Oock;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.275-275
    • /
    • 2013
  • Osteoblast is one of cells related with osseointegration and many research have conducted the adhesion of osteoblast onto the surface of implant. In the osseointegration, biocompatibility of the implant and cell adhesion to the surface are important factors. The researches related to cell adhesion have a direction from micro-scaled surface roughness to nano-scaled surface roughness with advancing nanotechnology. A cell reacts and sense to stimuli from extracellular matrix (ECM) and topography of the ECM [1]. Thus, for better osseointegration, we should provide an environment similar to ECM. In this study, we synthesize TiO2 nanowires using hydrothermal reaction because TiO2 provides inertness to titanium on its surface and enables it used as an implant material for the orthopedic treatment such as fixation of the bone fracture [2]. Ti substrate is immersed into NaOH aqueous solution. The solution are heated at $140{\sim}200^{\circ}C$ for various time (10~720 minutes). After heat treatment, we take out the sample and immerse it into HCl aqueous solution for 1 hour. The acid treated sample is heated again at $500^{\circ}C$ for 3 hours [3]. Then, we culture osteoblast on the TiO2 nanowires. For investigating cell adhesion onto nanostructured surface, we conduct several tests such as MTT assay, ALP (Alkaline phosphatase) activity assay, measuring calcium expression, and so on. These preliminary results of the cell culture on the nanowires are foundation for investigating cell-material interaction especially with nanostructure interaction.

  • PDF

임플란트 고정체와 지대주 간의 전하중 크기가 골응력에 미치는 영향에 대한 유한요소해석 (Effect of Implant Preload on the Marginal Bone Stresses Studied by Three Dimensional Finite Element Aanalysis)

  • 남효준;조광헌
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.127-138
    • /
    • 2012
  • 본 연구에서는 임플란트 고정체와 지대주 간의 전하중 크기가 임플란트 주위 변연골의 응력분포에 미치는 영향에 대해 조사하였다. 해석 모델은 하악골에 식립되는 단일 임플란트(solid형 지대주와 submerged 형 고정체)로 제작되었고, 외력 조건으로는 임플란트 지대주 상부에 100N의 기능력이 협설 방향으로 30도 경사져 협측으로 작용하도록 설정하였다. 전하중의 크기가 변연골 응력 분포에 어떠한 차이가 생기게 하는지를 조사하기 위해 다섯개의 다른 전하중의 크기(0, 200, 400, 600, 800N)를 부여하였다. 모든 분석은 선형 탄성을 가정하여 ABAQUS/CAE(ver6.10-1, HKS, Fremont, CA, USA) 프로그램을 사용하였다. 임플란트 주위 변연골 응력분포의 차이는 전하중의 크기와 관련이 있었다. 100N의 교합력 하에 전하중이 0인 경우 변연골(임플란트 벽에서 0.1mm 떨어진 부분)에서 압축 응력은 28.33MPa이었는데, 전하중을 200N 증가시킬 때마다 1.76MPa씩 증가하였다. 이런 방식으로 800N의 전하중을 가할 때 나타나는 최대 압축 응력은 35.18MPa이었다. 반면 변연골에서의 인장 응력은 전하중이 증가할 수록 감소하였다. 임플란트 고정체와 지대주 간의 전하중은 변연골에서의 압축 응력을 증가시킬 수 있으나 기능력에 비하면 그 효과는 미미할 것으로 판단된다.

자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구 (A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment)

  • 서민지;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.169-181
    • /
    • 2008
  • 치과용 자석의 개선으로 자성 어태치먼트를 이용한 임플란트 피개의치의 사용이 늘고 있다. 또한 여러 형태의 자성 어태치먼트가 개발되어 임상 상황에 따라 적절히 선택하여 사용할 수 있게 되었다. 이에 시중에 판매되는 세 가지 형태의 임플란트용 자성 어태치먼트를 이용해 자성 어태치먼트의 형태와 임플란트 수에 따른 임플란트 피개의치의 유지력을 비교 분석하였다. 식립된 임플란트가 1개인 경우를 1군, 2개인 경우 2군, 4개인 경우를 3군으로 하였고, 자성 어태치먼트의 형태에 따라 flat type, cushion type, dome type으로 세분하였다. Instron으로 수직방향, 사선방향, 전후방향의 인장력을 가하여 자성 어태치먼트의 형태에 따른 유지력의 차이, 힘의 방향에 따른 유지력의 차이, 자성 어태치먼트의 수에 따른 유지력의 변화를 비교 분석하여 다음의 결과를 얻었다. 1) 임플란트의 수와 상관없이 수직력은 flat type이 가장 컸으며, 측방력은 dome type이 가장 작은 것으로 나타났다. 2) 임플란트가 1개일 때 flat type의 수직력이 전후방회전력보다 크게 나타났고, 임플란트가 2개일 때는 dome type과 flat type이, 임플란트가 4개일 때는 cushion type과 flat type에서 수직력이 전후방회전력보다 크게 나타났다. 3) 임플란트 수에 따른 유지력 측정결과, 자석의 형태에 상관없이 임플란트 수가 많을수록 유지력은 증가하였다. 이상의 결과로 볼 때, 큰 유지력이 필요한 환자에게는 flat type이, 유해한 수평력이 존재하는 환자에게는 dome type의 이용이 유리하고, 임플란트가 1개일 때 flat type, 2개일 때 dome type과 flat type, 임플란트가 4개일 때 cushion type과 flat type이 피개의치의 안정성이 더 좋은 것으로 나타났다. 또한 자성 어태치먼트의 형태에 상관없이 임플란트의 수가 증가할수록 더 큰 유지력을 나타냈다. 따라서 임플란트 피개의치 사용 시 적절한 유지력과 안정성을 얻기 위해서 임플란트의 수와 자성 어태치먼트 형태의 고려가 필요하다고 사료된다.