• Title/Summary/Keyword: impedance ratio

Search Result 566, Processing Time 0.031 seconds

Numerical Analysis of the Dual-mode Resonator Using Shunt-Stub for the Filter Application (단락형 스터브를 이용한 이중모드 공진기의 필터 응용을 위한 수식적 해석)

  • Noh, Sun-Kuk;Yun, Tae-Soon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.327-332
    • /
    • 2018
  • In this paper, the value of inverter and the characteristics of the dual-mode resonator with the shunt-stub are analyzed and calculated. The value of inverter is function of the impedances and electrical lengths of the resonator and shunt-stub. According to suggested equation, the value of inverter is increased for the square root function. And the value of inverter is decreased as higher impedance of resonator and higher ripple. The bandwidth of the filter is increased as the ripple and the impedance ratio. Also, the center frequency of the filter is shifted as designed impedance. In order to show the designed method, the filter with the resonator's and stub's impedances of $70.7{\Omega}$, and $56.56{\Omega}$, respectively, is suggested by example.

Fabrication & Characteristics of SIR Microsrip Bandpass Filters using Deposition of High-Tc Superconducting Epitaxial Films (고온 초전도 에피텍셜 박막을 이용한 SIR 마이크로스트립 대역통과 필터의 제작 및 특성연구)

  • Park, Kyung-Kuk;Chung, Dong-Chul;Jeong, Yong-Chae;Lim, Sung-Hun;Yim, Seong-Woo;Han, Byoung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.326-332
    • /
    • 1999
  • In this paper, we designed and fabricated High-Tc Superconducting (HTS) microstrip bandpass filters using Stepped Impedance Resonators(SIR) and studied on their characteristics. The $high-T_c$ superconducting $Y_1Ba_2Cu_3O_{7-x}$ epitaxial films were deposited by Pulse Laser Deposition (PLD) system on MgO. The fabricated filters were designed so as to operate in Ku band with central frequency 17.25 GHz, bandwidth 2.896% and ripple 0.01 dB. These filters were composed of parallel coupled microstrip SIR of which impedance ratio (K) are 0.5, 1.5. In the measured response, HTS filters had showed insertion loss below -0.5 dB. For comparison with normal conducting filter, we fabricated the Au counterpart that consists of the resonators as K=1.5 in the same dimension and measured performance of the Au filter. In comparison, HTS filter designed optimally got superior response to gold conterpart.

  • PDF

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

The Accurate design of a Temperature stable Dielectric Stepped-Impedance Resonator (온도 변화에 안정한 유전체 Stepped-Impedance Resonator의 정확한 설계)

  • 임상규;김덕환안철
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.625-628
    • /
    • 1998
  • This paper presents the design method of a temperature stable stepped-impedance resonator using composite material. In this method temperature coefficient of dielectric constant $(\tau\varepsilon)$ and thermal expansion coefficient $(\alpha1)$ of dielectric material were considered. Ba(Zn1/3Nb2/3)O3 and CaZrO3 as composite material having opposite signs of temperature coefficient of dielectric constant were selected. The length of this resonator for the temperature stability of resonance frequency was calculated at 900MHz, 1.4㎓ and 1.9㎓. It was found that the ratio of the length of positive $\tau\varepsilon$ materal to the length of negative $\tau\varepsilon$ material is constant at various resonance frequencies.

  • PDF

Low-impedance Tetrodes using Carbon Nanotube-Polypyrrole Composite Deposition

  • Kim, Minseo;Shin, Jung Hwal;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.73-78
    • /
    • 2017
  • A tetrode is one of the neural electrodes, and it is widely used to record neural signals in the brain of a freely moving animal. The impedance of a neural electrode is an important parameter because it determines the signal-to-noise ratio of the recorded neural signals. Here, we developed a modification technique using carbon nanotube-polypyrrole composite nanostructures to decrease the impedances of tetrodes. The synthesis of the carbon nanotube and polypyrrole nanostructures was performed in two steps. In the first step, randomly dispersed carbon nanotubes and pyrrole monomers were gathered and aligned on the tetrode electrode. Next, they were electro-polymerized on the electrode surface. As the applied time (step-1 and step-2) and the offset voltage increased, the impedances of the tetrodes decreased. The modification technique is, therefore, an important and useful of lowering the impedances of tetrodes.

Impedance Analysis of a Solenoid Eddy Current Coil with Cylindrical Two-conductor Rods (원통형 2-도체를 가진 솔레노이드 와전류 코일의 임피던스 해석)

  • 김성덕;이상래
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.89-98
    • /
    • 1998
  • Some analytic results for a solenoid eddy current coil to test nondestructive conducting materials are described in this paper. Normalized impedance of solenoid coil encircling cylindrical conducting tubes or tow-conductor rods is analyzed. Electrical and magnetic properties such as conductivity, permeability and exciting frequency as well as the geometric ones of fill factor or radius ratio of the conductor are also considered. Impedance characteristics of the models obtained by numerical analysis are examined. Validation of the model is carried out using several samples of non-ferromagnetic conducting tubes and 2-conductor rods.

  • PDF

MINIATURIZED MICROSTRIP DUAL BAND-STOP FILTER USING STEPPED IMPEDANCE RESONATORS (P형 계단형 임피던스 공진기를 이용한 소형화된 마이크로스트립 이중 대역 저지 필터)

  • Park, Young-Bae;Kim, Gi-Rae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.43-46
    • /
    • 2011
  • A novel circuit structure of dual-band bandstop filters is proposed in this paper. This structure comprises two shunt-connected tri-section stepped impedance resonators with a transmission line in between. Theoretical analysis from the equivalent circuit and design procedures are described. We represented graphs for filter design from the derived synthesis equations by resonance condition of circuits. Notably, advantages of the proposed filter structure are compact size in design, wide range of realizable resonance frequency ratio, and more realizable impedances.

  • PDF

Cardiac systolic time intervals and heather index measured by impedance cardiography during postural changes (체위변화시 심장의 수축기 시간간격 및 Heather Index의 변화)

  • 고성경;김창규;김덕원
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.67-79
    • /
    • 1992
  • Cardiac systolic time intervals (STLs) and Heather index (HI) were used to access changes in left ventricular function of six male subjects exposed to postural changes,$0^{\circ}C$, ${\pm}2^{\circ}C$, ${\pm}45^{\circ}C$, ${\pm}90^{\circ}C$, Significant prolongation of the pre-ejection period (PEP) and PEP/ LVET ratio, shortening of the left ventricular ejection time (LVET), STI, HI and $1/PEP^{2}$were observed during exposure to both $+45^{\circ}C $ and $+90^{\circ}C $But the values measured during $-45^{\circ}C $ and$-90^{\circ}C $ were reversed. Changes in fluid shift, filling volume, preload, after load and sympathetic activities may account for the observed findings. Early response of cardiac foctions was recorded using impedance cardiography. This method is very simple but accurate. Thus it will be useful in this aerospace and work physiology. In conclusion, STIs appear to provide reliable noninvasive method for examining changes of cardiac function during exposure to postural changes.

  • PDF

The Experimental Method to Identify The Boundary Condition of Vibrating Structure (진동 구조물의 경계조건을 실험적으로 구하는 방법)

  • Kim, Young-Ju;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.525-530
    • /
    • 2000
  • The vibration shape of the structure with arbitrary boundary condition under excitation is determined by the governing equation and the boundary condition and driving force. In this paper, driving point impedance that is defined by the ratio of the driving force at one point to the velocity of that point is selected as a measure to identify the boundary condition. First, this paper deals with a string with arbitrary boundary condition. It is selected because of its simplicity, but generality of which exhibits the desired physical phenomena. Particularly the relation among the driving point impedance, the boundary condition and the vibration shape is dealt as a primary step to identify the boundary condition by using the driving point impedance.

  • PDF