• 제목/요약/키워드: impedance function

검색결과 473건 처리시간 0.024초

흡음재의 적절한 위치 및 임피던스 선정을 통한 효율적인 실내 소음 제어 (Good Choice of Positions and Impedances of Absorptive Materials for Effective Interior Noise Control)

  • 조성호;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.791-796
    • /
    • 2003
  • Some basic guidelines for changing non-uniform boundary condition in an acoustically small cavity are presented. In this paper, modal summation technique is used to represent inside sound field. From this formulation, corner effect is defined and proposed. The corner in a cavity is good position for changing boundary condition effectively. Impedance circle with same absorption coefficient is defined to find appropriate impedance of absorptive material for better noise control performance.

  • PDF

Impedance Analysis of Resistance Anomaly of $BaTiO_3$ based PTC thermistor

  • Chun, Myoung-Pyo;Myoung, Seong-Jae;Nam, Joong-Hee;Cho, Jeong-Ho
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.182-182
    • /
    • 2009
  • The effect of Re-oxidation on the PTCR properties of Sm-doped barium titanate ceramics was investigated by means of impedance spectroscopy. Electrical properties such as resistance vs. temperature, I-V curve were measured and microstructure was observed with SEM photography. Sample was fabricated with thick film process such as tape casting of green sheet, screen printing of electrode pattern, stacking, firing in reduced atmosphere and re-oxidation, etc. As the temperature of re-oxidation increases, resistance jump as a function of temperature enhances but resistance at room temperature increases. These behavior of resistance as a function of temperature, dependent on the re-oxidation condition, is analyzed with Cole-Cole impedance plot and is shown to be related with the degree of oxidation of grain boundary regardless of grain core during re-oxidation process of sample.

  • PDF

하이브리드 마이코로파 광대역 증폭기용 임피던스 정합회로 설계 (Design of broad-band impedance matching networks for hybrid microwave amplifier applications)

  • 김남태
    • 전자공학회논문지D
    • /
    • 제35D권5호
    • /
    • pp.11-17
    • /
    • 1998
  • In this paper, the synthesis procedufe of impedance matching network is presented for broad-band microwave amplifier design, whereby amplifier operating in the octave bandwidth is designed and fabricated in detail. The transfer function of the matching netowrks is synthesized by chebyshev approximation and element values for the networks of specified topology are calculatd for various MILs and ripples. After the transistor is modeled by negative-image device model, the synthesis procedure for matching networks is applied to broad-band amplifier design which has electrical performance of about 12dB gain in 4 to 8GHz range. Experimental results obtained from the fabricated amplifier are shown to approach the electrical performance designed in the given frequency range. Construction of the impedance matching networks by transfer function synthesis is very useful method for the design of broad-band microwave amplifiers.

  • PDF

A Novel Impedance Matching Topology for Magnetically Coupled Wireless Power Transfer

  • Lee, Gunbok;Park, Wee Sang
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.16-19
    • /
    • 2012
  • A modified 4-coil magnetic resonance wireless power transfer (MRWPT) system is proposed. Four coils based on 2-coil system with additional two matching coils were used in this topology. When Tx-Rx distance is changed, the input impedance is changed. However, it can be adjusted by coil parameters of matching coils to maintain impedance matching for maximum efficiency. The equivalent circuit of MRWPT system was analyzed for both transmission function and optimum coupling coefficient of the matching coils. By using four spiral resonant coils, these design considerations was experimentally verified. The measured data agreed well with the calculated data and the transmission function of the proposed system was more efficient than that of conventional 2-coil system.

체위변화시 심장의 수축기 시간간격 및 Heather Index의 변화 (Cardiac systolic time intervals and heather index measured by impedance cardiography during postural changes)

  • 고성경;김창규;김덕원
    • 대한인간공학회지
    • /
    • 제11권1호
    • /
    • pp.67-79
    • /
    • 1992
  • Cardiac systolic time intervals (STLs) and Heather index (HI) were used to access changes in left ventricular function of six male subjects exposed to postural changes,$0^{\circ}C$, ${\pm}2^{\circ}C$, ${\pm}45^{\circ}C$, ${\pm}90^{\circ}C$, Significant prolongation of the pre-ejection period (PEP) and PEP/ LVET ratio, shortening of the left ventricular ejection time (LVET), STI, HI and $1/PEP^{2}$were observed during exposure to both $+45^{\circ}C $ and $+90^{\circ}C $But the values measured during $-45^{\circ}C $ and$-90^{\circ}C $ were reversed. Changes in fluid shift, filling volume, preload, after load and sympathetic activities may account for the observed findings. Early response of cardiac foctions was recorded using impedance cardiography. This method is very simple but accurate. Thus it will be useful in this aerospace and work physiology. In conclusion, STIs appear to provide reliable noninvasive method for examining changes of cardiac function during exposure to postural changes.

  • PDF

생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정 (Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method)

  • 김거식;이상옥;서정환;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

Detection of Unbalanced Voltage Cells in Series-connected Lithium-ion Batteries Using Single-frequency Electrochemical Impedance Spectroscopy

  • Togasaki, Norihiro;Yokoshima, Tokihiko;Oguma, Yasumasa;Osaka, Tetsuya
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.415-423
    • /
    • 2021
  • For a battery module where single cells are connected in series, the single cells should each have a similar state of charge (SOC) to prevent them from being exposed to an overcharge or over-discharge during charge-discharge cycling. To detect the existence of unbalanced SOC cells in a battery module, we propose a simple measurement method using a single-frequency response of electrochemical impedance spectroscopy (EIS). For a commercially available graphite/nickel-cobalt-aluminum-oxide lithium-ion cell, the cell impedance increases significantly below SOC20%, while the impedance in the medium SOC region (SOC20%-SOC80%) remains low with only minor changes. This impedance behavior is mostly due to the elementary processes of cathode reactions in the cell. Among the impedance values (Z, Z', Z"), the imaginary component of Z" regarding cathode reactions changes heavily as a function of SOC, in particular, when the EIS measurement is performed around 0.1 Hz. Thanks to the significant difference in the time constant of cathode reactions between ≤SOC10% and ≥SOC20%, a single-frequency EIS measurement enlarges the difference in impedance between balanced and unbalanced cells in the module and facilitates an ~80% improvement in the detection signal compared to results with conventional EIS measurements.

임피던스 기반 저비용 구조물 건전성 모니터링 기법 (Low-cost Impedance Technique for Structural Health Monitoring)

  • 이종원
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.265-271
    • /
    • 2018
  • 본 연구에서는 임피던스(impedance)를 이용하여 저비용으로 구조물의 결함을 탐지할 수 있는 기법을 연구한다. 임피던스 기법은 구조물 건전성 모니터링을 위한 국부적 결함탐지의 대표적인 기법으로써, 압전재료를 구조물의 표면에 부착하여 구조물의 전기-역학적 어드미턴스(electro-mechanical admittance) 신호를 모니터링 함으로써 결함을 추정하는 기법이다. 이 기법을 적용하기 위하여 일반적으로 고가의 임피던스 분석기(impedance analyser)가 사용되는데, 기술의 효과적인 보급을 위해서는 저비용의 기법을 개발할 필요가 있다. 본 연구에서는 임피던스 분석기를 대체하여, 일반적으로 실험실에서 사용되는 함수발생기(function generator)와 디지털 멀티미터(digital multimeter)만을 이용하여 전달 임피던스(transfer impedance)를 측정함으로써 구조물에 발생하는 결함을 탐지할 수 있는 기법을 연구한다. 즉, 건전상태와 손상상태에서 측정되는 전압의 진폭비를 이용한 손상지수를 비교함으로써 결함 유무를 판정할 수 있는 기법을 연구한다. 강재 시편에 대한 전달 임피던스 실험을 수행하였는데, 출력 전압의 진폭비를 이용한 손상지수를 비교함으로써 결함 유무를 합리적으로 판정할 수 있었다. 본 연구는 임피던스 기반 저비용 결함탐지기법을 위한 기초연구로써, 향후 결함의 위치 및 정도를 판정할 수 있는 연구가 보완된다면 구조물 건전성 모니터링에 효과적으로 활용될 수 있을 것으로 판단된다.

손실 매질에 위치한 도체의 입력임피던스 수치계산 (Numerical Calculation for Input Impedance of a Conductor Located in the Loss Media)

  • 안창환
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.230-236
    • /
    • 2013
  • 본 논문은 대표적인 손실 매질인 대지에 위치한 도체의 입력임피던스를 MATLAB을 이용한 자체 프로그램을 활용하여 계산하고, 그 결과를 나타내었다. 도체의 입력임피던스는 안테나 이론의 전자계 모델에서 유도된 포클링턴방정식에 모멘트법이 적용되어 계산되었다. 결과의 정확도를 높이기 위해서 기저함수와 가중함수가 삼각함수인 켈러킨법을 적용하였다. 대지에 위치한 도체의 영상분은 수정된 영상법을 적용하여 고려하였다. 도체의 전류분포에 대한 자체 제작한 프로그램 결과와 NEC 프로그램의 결과를 비교하여 프로그램의 신뢰성을 확인하였다. 대지에 위치한 도체의 길이가 1 m, 2 m인 경우에 도전율에 따른 임피던스를 주파수에 따라 시뮬레이션 하였다. 실제 대지에 설치된 도체의 입력임피던스와 위상을 측정하고 동일한 조건에서의 시뮬레이션 결과와 비교하였다.

카오스 특징 추출에 의한 고저항 지락사고의 패턴인식 (Recognition of High Impedance Fault Patterns according to the Chaotic Features)

  • 신승연;공성곤
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1997년도 추계학술대회 학술발표 논문집
    • /
    • pp.311-314
    • /
    • 1997
  • This paper presents recognition of high impedance fault patterns based of chaotic features using the Radial Basis Function Network(RBFN). The chaos attractor is reconstructed from the fault current data for pattern recognition. The RBFN successfully classifies the three kinds of fault pattems and one normal pattem.

  • PDF