바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구 (A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance)

  • 장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF

공동주택의 소음 저감재 설치로 인한 바닥 충격음에 관한 연구 (A Study on Floor Impact Sound due to Resilient Materials in Apartment Buildings)

  • 김병길;김수련;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.5-10
    • /
    • 2004
  • Apartment Buildings have particularity to cluster together, especially, floor is close to resident, it is subject to dissatisfaction about impact noise between up and down floors. However, we require standard for counterplan to reduce the impact noise of floor. In point of fact, it difficult to objective evaluate for performance sound insulation that not physical sound volume but orignal form, means and effect of sound caused to complex noise in apartment house. Unique type of dwelling and structure pattern cause to noise of floor impact which is established by law for standard regulation. It is object to analysis and compare the result of performance sound insulation of upper floor impact and sample construct the subject resilient material of sound insulator

  • PDF

완충재 적용현장에서의 바닥충격음 차단성능 현황분석 (Evaluation of Floor Impact Sound Insulation Performance for Building Floors with Damping Materials)

  • 김경우;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.53-58
    • /
    • 2001
  • Floor impact sound has caused many acoustical complaints to the apartment building dwellers. The concrete floating floor construction is one of the most reasonable way to reduce floor impact sound. Recently, many damping materials are used in apartment buildings. In this study, to evaluate floor impact sound insulation performance, field tests were carried at five building floors with damping materials. The test results of impact sound insulation performance for five buildings showed good improvement in light weight impact sound after installation of damping materials, but heavy weight impact sound wasn't improved.

  • PDF

현장실험을 통한 목조바닥의 구성요소가 충격음 차단성능에 미치는 영향 평가 (Evaluation on Effect of Constitution of Timber Framed Floor on Insulation Performance Against Impact Sound by Field Measurements)

  • 박주생;이상준;김세종
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권6호
    • /
    • pp.431-444
    • /
    • 2012
  • 바닥구조의 충격음 차단성능은 바닥의 구성요소에 의해 많은 영향을 받는데, 그중 목조 바닥구조의 경우 중량의 흡읍층과 바닥구조의 강성이 주요한 영향인자로 고려되어 왔다. 본 연구에서는 국내 시공된 목조 건축물에 대해서 현장 실험을 통해 바닥 구성요소가 충격음 차단성능에 미치는 영향에 대해서 살펴보았다. 목조 바닥의 충격음 차단성능은 상대적으로 낮은 저주파수 대역에서의 음압레벨에 의해 전체적인 성능이 좌우되었으며, 흡읍층과 바닥구조의 강성 보강에 의해 저주파수 대역 음압레벨을 감소시켜 충격음 차단성능을 향상시킴을 알 수 있었다. 특히, 바닥난방을 위해 설치되는 시멘트 몰탈층과 같은 충격음 흡수층과 원래 경간의 중간 지점에 보를 설치하여 장선 경간을 줄여줌으로써 목조 바닥의 강성을 증가시킨 경우에 중량 충격음 차단성능이 크게 향상되었다.

강재프레임 모듈러주택의 바닥충격음 성능평가 (Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House)

  • 천영수;방종대;김갑득;유송이
    • 토지주택연구
    • /
    • 제5권2호
    • /
    • pp.81-89
    • /
    • 2014
  • 이 논문에서는 최근 관심을 모으고 있는 강재프레임 모듈러주택의 건식 바닥시스템을 대상으로 바닥충격음 차단성능을 확보하기 위하여 시도된 다양한 바닥구조의 실험결과에 대하여 제시하고 있다. 실험결과, 단위모듈 건식온돌 바닥구조는 완충구조로서 액체몰을 사용한 바닥구조 D31(D32)를 사용하는 조건에서 경량충격음의 경우 주택건설기준 등에 관한 규정에서 정하고 있는 바닥충격음 차단성능의 1등급 수준의 확보가 가능하고, 중량충격음의 경우는 바닥충격음 차단성능의 최저등급이기는 하나 기본적인 성능의 확보가 가능한 것으로 평가되었다.

천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구 (A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses)

  • 기노갑;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구 (An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings)

  • 윤세철;오종민
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

바닥마감재에 의한 바닥충격음 차음특성 연구 (A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings)

  • Gi, No-Gab;Kwon, Hyun-Jong;Song, Min-Jeong;Kim, Sun-Woo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.368.2-368
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound insulation performance of materials and elements used in building is falling down as they become thicker and lighter Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. (omitted)

  • PDF

바닥충격음 차단성능 평가방법의 상호비교 (Comparison of Rating Methods for the Floor Impact Sound Insulation Performance)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF