• Title/Summary/Keyword: impact noise

Search Result 1,322, Processing Time 0.028 seconds

Improved dynamic model of the impact hammer (개선된 충격해머의 동역학적 모델)

  • Lim, Byoung-Duk;Park, Jung-Hyun;Heo, Joon-Hyeok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.372.1-372
    • /
    • 2002
  • Although impact hammer is widely used as a convenient excitation tool in structural modal testing, little is known about the dynamic charateristics of its impulse mechanism. Transmission of the impulsive force to the structure depends on the dynamic properties of the impact hammer as well as the stiffness of the tip. An improved dynamic model of the impact hammer is proposed in this study with numerical simulations based on this model. (omitted)

  • PDF

A study on the annoyance and disturbance of floor impact noise according to noise sensitivity based on questionnaire survey (설문조사를 통한 소음 민감도에 따른 층간소음에 의한 성가심과 생활방해 연구)

  • Jeong, Jeongho;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2018
  • The response to noise may differ depending on the respondent's noise sensitivity. In this study, it was investigated that the noise sensitivity, the annoyance and disturbance of floor impact noise and opinions on their neighbors. The questionnaire respondents were divided into two or three groups based on noise sensitivity, and annoyance and disturbance on floor impact sound were compared. The noise sensitivity questionnaire method was presented. The questionnaire survey was conducted on 233 residents of Seoul, Gyeonggi - do area. As a result of the questionnaire survey, when the sensitivity group was divided into three groups, it was found that there was a significant difference between the groups with the noise sensitivity and the disturbance reaction. As a result of the opinions on their neighbors, positive responses to neighbors increased with age. Also, it was found that there was a low perception of inter - floor noise and life disturbance of the group having positive feelings about neighbors.

Influence of Chemical composition of Ethylene-Vinyl Acetate Copolymers on Impact Noise Damping of Composites (에틸렌-초산비닐 공중합체의 공중합 조성이 복합체의 충격음 흡수성능에 미치는 영향)

  • 이현종
    • Journal of Korea Foresty Energy
    • /
    • v.18 no.2
    • /
    • pp.55-61
    • /
    • 1999
  • This study was carried out to investigate the influence of viscoelastic properties(or chemical composition) of a series of ethylen-viny1 acetate copolymers on impact noise and vibration damping of wood/polymer/wood sandwich composites. The impact noise and vibration damping of composites were very sensitive to the state of molecular motion of polymer. The noise and vibration damping of composites were maximum when the polymer was under the glass transition(vinylacetate 55~75%) at the test-temperature, and minimum rubbery state(vinyl-acetate 47~20%) or glassy state(vinylacetate 100~87%). The polymer under glass transition reduced the impact noise by 6~12 dB.

  • PDF

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

Hourly Environmental Pollution (Air Pollution and Noise) Mapping Method by the Traffic Volume Change (시간별 교통량 변화에 따른 환경오염지도(대기 및 소음) 구축방안에 관한 연구)

  • Cho, Dong-Myung;Kwon, Woo-Taeg;Na, Young
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.485-494
    • /
    • 2007
  • Air pollution and traffic noise from roads distributed near residential area has been a major social problem. In this study, an environmental pollution map for a residential area of Shihung-city was made by an expectation model based on hourly traffic volume change. Using the result from the model, a plan to reduce population in the residential area was established. The result of the modelling is summarized as follows: 1. At peak traffic hours (18 o'clock), 301-500 degree in hazardous and $d_{25}$ degree (25% of the residents are suffering extremely from the noise) in noise pollution were predicted in Jeongwang Main Road in Shihung city. 2. The calculated critical pollutant standard index, PSI showed the air pollution level, especially PM-10 high enough to require re-entrainment. 3. It was expected air pollution would extensively extend over the area distribution of each degree. However, noise pollution problem was limited to the area near roads.

The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form (EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발)

  • Park, Cheol-Yong;Kim, Sang-Hoon;Jang, Dong-Woon;Jang, Cheol-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

A study on the performance test and acoustic design of interference type noise reduction device for railway noise (철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구)

  • Cho, Jun-Ho;Koh, Hyo-In
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad (바닥충격음 완충재의 동적특성과 소음저감 성능 비교)

  • Yang, Soo-Young;Lee, Dong-Hoon;Hong, Boung-Kuk;Song, Hwa-Young;Lee, Joo-Wone
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

Performance of floor coverings by impact sound (실 충격원에 대한 바닥마감재 성능 분석)

  • Chung, Jinyun;Im, Jungbin;Lee, Sungchan;Kim, Kyoungwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

A Tendency of Prediction Technique for the Assessment of Railway Noise (철도소음 영향평가를 위한 예측기술 동향)

  • Cho, Jun-Ho;Park, Young-Min;Sun, Hyo-Sung;Hong, Woong-Gi
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • Since 1990s, the railway noise has been researched and developed in our nation. First of all, what's causing the noise and how to eliminate the cause of the noise must be found out. Secondly, cutting off the propagation path of the noise from the noise source to the receiving points. In this study the characteristics of prediction formula for the assessment of railway noise used in some nations including Korea were investigated. In order to develop the prediction formula of the railway noise, the noise radiated from railway vehicle, rails and sleepers, characteristics of noise barrier, velocity of train, ground effects, roughness should be analyzed and predicted. Especially, on the basis of acoustics, the characteristics of source are applied to acoustic power and directivity information.