저자들은 BRCA 유전자 변형 환자의 양측 삼중음성 유방암의 선행화학요법에 대한 상이한 반응에 대한 증례를 보고한다. 우측은 T1cN0M0, 좌측은 T4dN3aM0으로 각각 진단되었다. 환자는 Adriamycin, cyclophosphamide 항암요법 4차, docetaxel 4차를 시행 받았다. 양측 유방암은 첫 번째 항암요법 4차 이후에 부분 관해를 보였다. Docetaxel 항암요법 중 양측 유방암은 상이한 반응을 보였다. 우측 유방암은 지속적인 관해를 보였으나, 좌측 유방암은 진행되는 양상을 보였다. 전절제술 결과, 우측 유방암은 0.3 cm, 좌측은 12 cm로 측정되었다. 동일한 삼중음성 유방암에서도 항암요법에 대하여 좌우가 상이한 반응을 보일 수 있으므로, 면밀한 추적 관찰이 고려되어야 할 것이다.
Objective: To investigate the predictive value of radiomics features based on cardiac magnetic resonance (CMR) cine images for left ventricular adverse remodeling (LVAR) after acute ST-segment elevation myocardial infarction (STEMI). Materials and Methods: We conducted a retrospective, single-center, cohort study involving 244 patients (random-split into 170 and 74 for training and testing, respectively) having an acute STEMI (88.5% males, 57.0 ± 10.3 years of age) who underwent CMR examination at one week and six months after percutaneous coronary intervention. LVAR was defined as a 20% increase in left ventricular end-diastolic volume 6 months after acute STEMI. Radiomics features were extracted from the oneweek CMR cine images using the least absolute shrinkage and selection operator regression (LASSO) analysis. The predictive performance of the selected features was evaluated using receiver operating characteristic curve analysis and the area under the curve (AUC). Results: Nine radiomics features with non-zero coefficients were included in the LASSO regression of the radiomics score (RAD score). Infarct size (odds ratio [OR]: 1.04 (1.00-1.07); P = 0.031) and RAD score (OR: 3.43 (2.34-5.28); P < 0.001) were independent predictors of LVAR. The RAD score predicted LVAR, with an AUC (95% confidence interval [CI]) of 0.82 (0.75-0.89) in the training set and 0.75 (0.62-0.89) in the testing set. Combining the RAD score with infarct size yielded favorable performance in predicting LVAR, with an AUC of 0.84 (0.72-0.95). Moreover, the addition of the RAD score to the left ventricular ejection fraction (LVEF) significantly increased the AUC from 0.68 (0.52-0.84) to 0.82 (0.70-0.93) (P = 0.018), which was also comparable to the prediction provided by the combined microvascular obstruction, infarct size, and LVEF with an AUC of 0.79 (0.65-0.94) (P = 0.727). Conclusion: Radiomics analysis using non-contrast cine CMR can predict LVAR after STEMI independently and incrementally to LVEF and may provide an alternative to traditional CMR parameters.
Subin Heo;Seung Soo Lee;So Yeon Kim;Young-Suk Lim;Hyo Jung Park;Jee Seok Yoon;Heung-Il Suk;Yu Sub Sung;Bumwoo Park;Ji Sung Lee
Korean Journal of Radiology
/
제23권12호
/
pp.1269-1280
/
2022
Objective: This study aimed to evaluate the usefulness of quantitative indices obtained from deep learning analysis of gadoxetic acid-enhanced hepatobiliary phase (HBP) MRI and their longitudinal changes in predicting decompensation and death in patients with advanced chronic liver disease (ACLD). Materials and Methods: We included patients who underwent baseline and 1-year follow-up MRI from a prospective cohort that underwent gadoxetic acid-enhanced MRI for hepatocellular carcinoma surveillance between November 2011 and August 2012 at a tertiary medical center. Baseline liver condition was categorized as non-ACLD, compensated ACLD, and decompensated ACLD. The liver-to-spleen signal intensity ratio (LS-SIR) and liver-to-spleen volume ratio (LS-VR) were automatically measured on the HBP images using a deep learning algorithm, and their percentage changes at the 1-year follow-up (ΔLS-SIR and ΔLS-VR) were calculated. The associations of the MRI indices with hepatic decompensation and a composite endpoint of liver-related death or transplantation were evaluated using a competing risk analysis with multivariable Fine and Gray regression models, including baseline parameters alone and both baseline and follow-up parameters. Results: Our study included 280 patients (153 male; mean age ± standard deviation, 57 ± 7.95 years) with non-ACLD, compensated ACLD, and decompensated ACLD in 32, 186, and 62 patients, respectively. Patients were followed for 11-117 months (median, 104 months). In patients with compensated ACLD, baseline LS-SIR (sub-distribution hazard ratio [sHR], 0.81; p = 0.034) and LS-VR (sHR, 0.71; p = 0.01) were independently associated with hepatic decompensation. The ΔLS-VR (sHR, 0.54; p = 0.002) was predictive of hepatic decompensation after adjusting for baseline variables. ΔLS-VR was an independent predictor of liver-related death or transplantation in patients with compensated ACLD (sHR, 0.46; p = 0.026) and decompensated ACLD (sHR, 0.61; p = 0.023). Conclusion: MRI indices automatically derived from the deep learning analysis of gadoxetic acid-enhanced HBP MRI can be used as prognostic markers in patients with ACLD.
Kyehwan Kim;Seung Do Lee;Hyo Jin Lee;Hangyul Kim;Hye Ree Kim;Yun Ho Cho;Jeong Yoon Jang;Min Gyu Kang;Jin-Sin Koh;Seok-Jae Hwang;Jin-Yong Hwang;Jeong Rang Park
Journal of Cardiovascular Imaging
/
제31권2호
/
pp.85-95
/
2023
BACKGROUND: The prognostic utility of follow-up transthoracic echocardiography (FU-TTE) in patients with hypertrophic cardiomyopathy (HCM) is unclear, specifically in terms of whether changes in echocardiographic parameters in routine FU-TTE parameters are associated with cardiovascular outcomes. METHODS: From 2010 to 2017, 162 patients with HCM were retrospectively enrolled in this study. Using echocardiography, HCM was diagnosed based on morphological criteria. Patients with other diseases that cause cardiac hypertrophy were excluded. TTE parameters at baseline and FU were analyzed. FU-TTE was designated as the last recorded value in patients who did not develop any cardiovascular event or the latest exam before event development. Clinical outcomes were acute heart failure, cardiac death, arrhythmia, ischemic stroke, and cardiogenic syncope. RESULTS: Median interval between the baseline TTE and FU-TTE was 3.3 years. Median clinical FU duration was 4.7 years. Septal trans-mitral velocity/mitral annular tissue Doppler velocity (E/e'), tricuspid regurgitation velocity, left ventricular ejection fraction (LVEF), and left atrial volume index (LAVI) at baseline were recorded. LVEF, LAVI, and E/e' values were associated with poor outcomes. However, no delta values predicted HCM-related cardiovascular outcomes. Logistic regression models incorporating changes in TTE parameters had no significant findings. Baseline LAVI was the best predictor of a poor prognosis. In survival analysis, an already enlarged or increased size LAVI was associated with poorer clinical outcomes. CONCLUSIONS: Changes in echocardiographic parameters extracted from TTE did not assist in predicting clinical outcomes. Cross-sectionally evaluated TTE parameters were superior to changes in TTE parameters between baseline and FU at predicting cardiovascular events.
Wonsuk Choi;Chi-Hoon Kim;In-Chang Hwang;Chang-Hwan Yoon;Hong-Mi Choi;Yeonyee E Yoon;In-Ho Chae;Goo-Yeong Cho
Journal of Cardiovascular Imaging
/
제30권3호
/
pp.185-196
/
2022
BACKGROUND: Two-dimensional (2D) strain provides more predictive power than ejection fraction (EF) in patients with ST-elevation myocardial infarction (STEMI). 3D strain and EF are also expected to have better clinical usefulness and overcome several inherent limitations of 2D strain. We aimed to clarify the prognostic significance of 3D strain analysis in patients with STEMI. METHODS: Patients who underwent successful revascularization for STEMI were retrospectively recruited. In addition to conventional parameters, 3D EF, global longitudinal strain (GLS), global area strain (GAS), as well as 2D GLS were obtained. We constructed a composite outcome consisting of all-cause death or re-hospitalization for acute heart failure or ventricular arrhythmia. RESULTS: Of 632 STEMI patients, 545 patients (86.2%) had a reliable 3D strain analysis. During median follow-up of 49.5 months, 55 (10.1%) patients experienced the adverse outcome. Left ventricle EF, 2D GLS, 3D EF, 3D GLS, and 3D GAS were significantly associated with poor outcomes. (all, p < 0.001) The maximum likelihood-ratio test was performed to evaluate the additional prognostic value of 2D GLS or 3D GLS over the prognostic model consisting of clinical characteristics and EF, and the likelihood ratio was 15.9 for 2D GLS (p < 0.001) and 1.49 for 3D GLS (p = 0.22). CONCLUSIONS: The predictive power of 3D strain was slightly lower than the 2D strain. Although we can obtain 3D strains, volume, and EF simultaneously in same cycle, the clinical implications of 3D strains in STEMI need to be investigated further.
Han Na Lee;Jin An;Miji Lee;Hye Jeon Hwang;Jooae Choe;Jihye Yoon;Ji-Hyang Lee;Min-Hye Kim;Young-Joo Cho;Sang Min Lee;Tae-Bum Kim;Joon Beom Seo
Korean Journal of Radiology
/
제25권7호
/
pp.673-683
/
2024
Objective: To evaluate the role of visual and quantitative chest CT parameters in assessing treatment response in patients with severe asthma. Materials and Methods: Korean participants enrolled in a prospective multicenter study, named the Precision Medicine Intervention in Severe Asthma study, from May 2020 to August 2021, underwent baseline and follow-up chest CT scans (inspiration/expiration) 10-12 months apart, before and after biologic treatment. Two radiologists scored bronchiectasis severity and mucus plugging extent. Quantitative parameters were obtained from each CT scan as follows: normal lung area (normal), air trapping without emphysema (AT without emph), air trapping with emphysema (AT with emph), and airway (total branch count, Pi10). Clinical parameters, including pulmonary function tests (forced expiratory volume in 1 s [FEV1] and FEV1/forced vital capacity [FVC]), sputum and blood eosinophil count, were assessed at initial and follow-up stages. Changes in CT parameters were correlated with changes in clinical parameters using Pearson or Spearman correlation. Results: Thirty-four participants (female:male, 20:14; median age, 50.5 years) diagnosed with severe asthma from three centers were included. Changes in the bronchiectasis and mucus plugging extent scores were negatively correlated with changes in FEV1 and FEV1/FVC (ρ = from -0.544 to -0.368, all P < 0.05). Changes in quantitative CT parameters were correlated with changes in FEV1 (normal, r = 0.373 [P = 0.030], AT without emph, r = -0.351 [P = 0.042]), FEV1/FVC (normal, r = 0.390 [P = 0.022], AT without emph, r = -0.370 [P = 0.031]). Changes in total branch count were positively correlated with changes in FEV1 (r = 0.349 [P = 0.043]). There was no correlation between changes in Pi10 and the clinical parameters (P > 0.05). Conclusion: Visual and quantitative CT parameters of normal, AT without emph, and total branch count may be effective for evaluating treatment response in patients with severe asthma.
목 적 : Deep inspiration breath-hold(DIBH) 기법을 이용한 좌측 유방암의 방사선치료 중 환자의 호흡과 심장 위치의 변화에 대한 분석을 통해 DIBH 기법의 치료 재현성을 평가하고자 한다. 대상 및 방법 : 유방보존수술 후 DIBH 기법을 적용한 좌측 유방암 환자 3명을 대상으로 하였다. 전산화치료계획시스템(Eclipse version 10.0, Varian, USA)을 이용하여 자유호흡상태 Computed Tomography(CT)와 DIBH CT에서 동일한 전산화치료계획을 수립하여 심장의 체적과 선량을 비교하였고, RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)의 데이터를 이용하여 환자의 호흡을 분석하였다. 치료 중 Electronic portal imaging device(EPID)를 이용한 Cine Acquisition 방법으로 영상을 획득하여 Varian 사의 Offline Review (ARIA 10, Varian, USA)에서 심장의 장축 거리를 측정하였다. 조사야 내 심장의 포함 정도를 비교 평가하기 위하여 동일한 3개(A, B, C)의 지점에서 길이 측정을 진행하였다. 결 과 : 자유호흡상태와 DIBH를 적용한 두 가지 전산화치료계획에서 심장평균선량 (6.82 vs 1.91 Gy), 심장의 V30 (68.57 vs $8.26cm^3$), V20(76.43 vs $11.34cm^3$)의 차이를 확인 할 수 있었다. 각 환자의 치료 중 DIBH 구간에서 호흡 진폭에 대한 표준편차의 평균값은 각각 ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$로 분석되었다. 치료 중 획득한 영상에서 조사야 내에 포함되는 심장의 길이를 측정한 후 전산화치료계획에서의 심장의 길이와 비교한 결과 최대값은 0.32 cm, 최소값은 0.00 cm로 확인 되었다. 결 론 : 좌측 유방암 환자 치료 시 DIBH를 적용할 경우 심장에 들어가는 선량을 줄이기 위한 전산화치료계획을 수립하는데 용이할 뿐만 아니라, 실제 치료 중에도 심장의 위치에 대한 정확한 재현성과 심장 선량을 감소시킬 수 있다는 것을 확인할 수 있었다. 또한 EPID의 Cine acquisition 방법은 치료 선량 외에 추가적인 선량 없이 DIBH의 재현성 평가를 위한 매우 효과적인 방법이라고 생각된다.
I. 목적 : 본 연구에서는 복부의 이상적 영상 구현을 위한 Film Screen (F.S) System과 Computed Radiography(C.R) System의 촬영조건의 차이를 비교 분석해 보고, C.R system에서 촬영조건 변화에 따른 영상의 특성을 분석함으로써, C.R 환경에서 촬영조건 설정의 중요성을 살펴보고자 한다. II. 대상 및 방법 : F.S system에서 촬영 조건을 70kVp로 고정시키고, mAs를 단계적으로 변화시켜 복부 단순겸사를 시행하여 영상을 획득한 후, 진단방사선과 전문의와 방사선사로 구성된 영상평가 팀의 정량적, 정성적 분석을 통하여 F.S system 최적의 영상을 선정하였다. 동일 환자를 대상으로 C.R system 에서 위와 동일한 방법으로 영상을 획득한 후, F.S system과 C.R system의 영상의 특성곡선(Characteristic Curves)을 비교분석하고, C.R system에서 촬영조건 변화에 따른 복부 장기의 농도변화 및 영상의 특정을 비교 평가하였다. 마지막으로, F.S system과 C.R system의 최적의 영상 획득을 위한 촬영조건의 차이를 비교 분석하고, C.R 환경에서 촬영조건의 중요성을 살펴보았다. III. 결과 : F.S system에서 영상평가팀의 평가를 통하여 선택된 최적 영상의 촬영 조건은 70kVp, 20mAs로 나타났다. C.R system에서는 촬영조건 12mAs, 70kVp에서 복벽과 직접노출구역의 농도 차이가 최대인, 진단적 가치가 높은 영상을 얻을 수 있었다. C.R system에서는 (70kVp로 고정)변화한 mAs량(3.2mAs, 8mAs, 12mAs, 16mAs, 20mAs)에 상관없이 복부 장기는 거의 통일한 농도를 나타냈으며 12mAs 기준으로 노출 조건의 감소 또는 증가에 따라서 복벽과 직접노출부분의 명확한 구분이 불가능하였으며, mAs량이 낮아질수록 양자반점(Quantum Mottle)으로 인한 artifact는 증가함을 볼 수 있었다. IV. 결론 : 위의 실험 결과 본원 system의 복부단순검사에서는 C.R system 사용 시 F.S system 보다 촬영 조건을 약 40% 감소시킬 수 있었다. C.R환경에서 x-ray장치 Image processing 장치, 자동 감도조절(EDR : exposure data recognition processing) 장치, PACS 등 사용하는 장비들의 특성을 분석하여 적정 노출조건을 재설정한다면, 최소의 피폭선량으로 최대의 영상정보를 지닌 진단적 가치가 높은 영상의 획득이 가능하다고 사료된다.
목 적 : 편마비를 가진 뇌성마비 환아에서 확산 텐서강조영상을 이용한 3차원 피질척수로 영상의 이상 소견의 유형과 임상적인 소견과의 일치도를 알아보기 위하여 연구를 시행하였다. 방 법 : 2003년 3월부터 2007년 8월까지 영남대학교 의과대학 부속병원 소아과 및 재활의학과에서 확산 텐서강조영상 검사를 시행했던 편마비를 가진 뇌성마비 환아 13예를 대상으로 FACT기법을 사용하여 피질척수로의 3차원 신경섬유로 영상을 재구성하여 분석하였다. 기본 관심영역은 전 뇌교, 두 번째 관심영역은 전 수질을 통과하는 피질척수로로 설정하여 두 부위를 동시에 통과하는 신경섬유로를 최종 관심 신경섬유로로 하였다. 분할비등방도와 각의 종료 기준은 각각 0.3과 70도로 하였다. 결 과 : 삼차원 피질척수로 영상에서 이상 소견으로는 피질척수로의 단절과 신경섬유의 양적 감소, 피질척수로의 무형성, 횡뇌량 신경섬유 그리고 비정상적인 피질척수로의 재구성 등의 유형이 있었으며 전체 13예 중 피질척수로의 단절이 10예(76.9%), 신경섬유의 양적 감소가 8예(61.5%)에서 관찰되었다. 피질척수로의 무형성은 3예(23.1%)에서 관찰되었고 횡뇌량 신경섬유로는 2예(15.4%), 비정상적인 피질척수로의 재구성은 4예(30.8%)에서 관찰되었다. 임상적인 소견과 3차원 피질척수로의 이상소견이 일치되는 예가 13예 중 11예(84.6%)였다. 결 론 : 확산 텐서강조영상을 이용한 3차원 피질척수로 영상은 다양한 이상 소견과 임상적인 소견과의 높은 일치도를 보여 편마비 뇌성마비의 진단과 치료에 매우 유용한 검사로 사용될 수 있다고 생각된다. 그러나 향후 검사법의 표준화 등 보완을 요하는 연구가 더 필요하다고 생각된다.
목적: 호흡게이트PET(이하 RGPET)을 이용하여 호흡에 의한 PET영상의 인공산물의 감소 효과를 호흡모형 팬톰을 제작하여 분석하였다. 특히 4D-CT를 시행하여 얻은 동일 호흡위상의 CT영상을 이용하여 RGPET의 감쇠 보정에 이용할 수 있도록 CT영상을 재구성하는 방법을 제시하였다. 대상 및 방법: 반복주기 6초, 진동 폭 26mm의 운동 팬톰에 각각 3 ml syringe와 10, 30 ml의 vial에 18.5 MBq (0.5 mCi) 18-F FDG를 주입한 후, 게이트의 유무에 따라 Discovery ST (GE Medical System, Milwaukee. WU) PET-CT 스캐너를 사용하여 PET/CT스캔을 시행하였다. 이때 호흡추적장치로는 적외선 CCD카메라 방식의 Real-Time Position Management (Varian Medical Systems, Palo Alto, CA)을 사용하였다. 호흡게이트PET 및 4D-CT스캔은 10% 호흡위상백분위 별로 총 10세트의 영상을 각각 획득하였다. 이와 같이 운동주기를 10개의 소 구간으로 분할하여 얻은 PET과 CT영상으로부터 각 물체의 위치를 분석하였고, 물체의 크기에 따른 운동 인공산물의 크기와 PET 계수 값의 감소간의 상관관계를 분석하였다. 결과: RGPET과 4D-CT상에서 물체의 중심위치를 호흡위상별로 분석한 결과, 오차범위 내에서 실제 위치와 잘 일치하였다. 게이트를 시행하지 않은 PET에서 관측된 물체의 크기는 상대적 운동크기에 비례하여 증가하여, 운동범위가 물체 크기의 2배가 되면 부피를 2.5배 가량 과대 평가하였다. 반면, 최대 uptake수치는 50% 가량 줄었다. 결론: RGPET을 통해 PET영상에서 나타나는 호흡으로 인한 인공산물의 대부분을 제거할 수 있음을 확인할 수 있었으며, 4D-CT스캔을 통해 획득한 동일위상의 CT 영상을 이용하여 보다 정확한 감쇠 보정 및 영상융합 결과를 얻었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.