• 제목/요약/키워드: imaging property

검색결과 154건 처리시간 0.03초

RETRIEVING AEROSOL AMOUNT FROM GEOSTATIONARY SATELLITE

  • Yoon, Jong-Min;Kim, Jhoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.232-235
    • /
    • 2006
  • Using 30 days of hourly visible channel data and DIScrete Ordinate Radiative Transfer (DISORT) model (6S), Aerosol optical depth (AOD) at $0.55{\mu}m$ was retrieved over the East Asia. In contrast with the AOD retrieval using low-earth-orbit satellites such as MODIS (Moderate-Res olution Spectroradiometer) or MISR (Multiangle Imaging SpectroRadiometer), this algorithm with geostationary satellite can improve the monitoring of AOD without the limitation of temporal resolution. Due to the limited number of channels in the conventional meteorological imager onboard the geostationary satellite, an AOD retrieval algorithm utilizing a single visible channel has been introduced. This single channel algorithm has larger retrieval error of AOD than other multiple-channel algorithm due to errors in surface reflectance and atmospheric property. In this study, the effects of manifold atmospheric and surface properties on the retrieval of AOD from the geostationary satellite, are investigated and compared with the AODs from AERONET and MODIS. To improve the accuracy of retrieved AOD, efforts were put together to minimize uncertainties through extensive sensitivity tests. This algorithm can be utilized to retrieve aerosol information from previous geostationary satellite for long-term climate studies.

  • PDF

다수의 평면을 가지는 모델기반 카메라 추적방법 (Camera Tracking Method based on Model with Multiple Planes)

  • 이인표;남보담;홍현기
    • 한국게임학회 논문지
    • /
    • 제11권4호
    • /
    • pp.143-149
    • /
    • 2011
  • 본 논문에서는 다수의 평면을 가지는 모델기반 카메라 추적 시스템이 제안된다. 상품의 정보를 표기하기 위한 2차원 바코드(barcode)로 널리 사용되는 QR(Quick Response) 코드를 인식하여 해당 물체의 3차원 모델을 임포팅한다. 그리고 관련 기하정보를 이용하여 모델의 주요 정점(vertex)을 추출하고 옵티컬 플로우(optical flow)를 이용하여 추적한다. 클리핑 알고리즘으로 다수의 평면을 가지는 물체의 평면 영역을 구별하고 매칭된 특징으로부터 호모그래피를 계산하여 초기 단계의 대략적인 카메라 움직임 파라미터를 추정한다. 이후 카메라의 움직임에 따라 다양한 평면에 존재하는 특징점과 해당 3차원 정보를 선형 방정식으로 구성하고 DLT(Direct Linear Transform) 방법을 적용한다. 최종 단계에서 번들 조정(Bundle Adjustment) 알고리즘을 이용해 카메라의 움직임 파라미터에 포함된 에러를 최소화 한다.

휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성 (Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application)

  • 강동헌;채미나;홍세원
    • 한국전기전자재료학회논문지
    • /
    • 제29권8호
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

광학 영상을 위한 Cy5.5가 결합된 생체적합성 고분자 마이셀 나노입자의 제조 및 특성분석 (Preparation and Characterization of Cy5.5-conjugated Biocompatible Polymeric Micellar Nanoparticles for Optical Imaging)

  • 김효정;김병진;이하영;정석현;정서영;육순홍;신병철;성하수;최연웅;하대철;조선행;이수민
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권6호
    • /
    • pp.393-400
    • /
    • 2009
  • PHEA (hydroxyethyl-aspartamide)-mPEG (methoy-polyethyleneglycol)-$C_{16}$ (hexadecylamine)-ED (ethylenediamine) was prepared as a drug delivery carrier. The structure and molecular weight of polymers were characterized by $^1H$-NMR and gel permeation chromatography. Micelle size and shape were measured by electro-photometer light scattering and transmission electron microscope. The mean diameter of micelles was 23 nm in aqueous solution. To evaluate the potential of these polymeric micelles as a drug carrier, PSI-mPEG-$C_{16}$-ED was conjugated with Cy5.5 for Near-Infrared Fluorescent (NIRF) based optical imaging. PSI-mPEG-$C_{16}$-ED-Cy5.5 was injected intravenously into mice (n=5) and in vivo NIRF imaging was performed during 48 h after injection. The biodistribution study at 24 h after injection showed the longcirculation property of PSI-mPEG-$C_{16}$-ED-Cy5.5. Therefore, PSI-mPEG-$C_{16}$-ED micelles could be a promising drug carrier and imaging agent.

a-Si:H Image Sensor for PC Scanner

  • Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.116-120
    • /
    • 2007
  • In this paper, the image sensor using the a-Si:H TFT is proposed. The optimum amorphous silicon thin film is deposited using plasma enhanced chemical vapor deposition (PECVD). TFT and photodiode both with the thin film are fabricated and form image sensor. The photodiode shows that $I_{dark}\;is\;{\sim}10^{-13}\;A,\;I_{photo}\;is\;{\sim}10^{-9}\;A\;and\;I_{photo}/I_{dark}\;is\;{\sim}10^4$, respectively. In the case of a-Si:H TFT, it indicates that $I_{on}/I_{off}\;is\;10^6$, the drain current is a few ${\mu}A\;and\;V_{th}\;is\;2{\sim}4$ volts. For the analysis on the fabricated image sensor, the reverse bias of -5 volts in ITO of photodiode and $70 {\mu}sec$ pulse in the gate of TFT are applied. The image sensor with good property was conformed through the measured photo/dark current.

스마트 영상 장비를 위한 BCS-SPL 복호화 기법의 효과적인 고속화 방안 (An Effective Fast Algorithm of BCS-SPL Decoding Mechanism for Smart Imaging Devices)

  • 류중선;김진수
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.200-208
    • /
    • 2016
  • Compressed sensing is a signal processing technique for efficiently acquiring and reconstructing in an under-sampled (i.e., under Nyquist rate) representation. A block compressed sensing with projected Landweber (BCS-SPL) framework is most widely known, but, it has high computational complexity at decoder side. In this paper, by introducing adaptive exit criteria instead of fixed exit criteria to SPL framework, an effective fast algorithm is designed in such a way that it can utilize efficiently the sparsity property in DCT coefficients during the iterative thresholding process. Experimental results show that the proposed algorithm results in the significant reduction of the decoding time, while providing better visual qualities than conventional algorithm.

주파수 영역 확산광 단층촬영 장치를 이용한 광 팬텀 및 인체조직의 광 계수 측정 (Optical Property Measurements of Optical Phantoms and Honan Tissues Using Frequency-Domain Diffuse Optical Tomography)

  • 호동수;권기운;엄기윤;이승덕;김법민
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.229-234
    • /
    • 2007
  • Diffuse optical tomography (DOT) is a relatively new medical imaging modality which uses near infrared light to image large-sized tissues noninvasively. We constructed a frequency-domain DOT system to measure the optical properties of optical phantoms and human tissues. The FD-DOT uses the intensity-modulated infrared light source that illuminates the biological tissues. The phase shift and modulation changes at each detector site are separately processed to measure the optical properties. The absorption and scattering coefficients are separately estimated using inverse algorithms.

ANALYSIS OF WATER STRESS OF GREENHOUSE PLANTS USING THERMAL IMAGING

  • K. H. Ryu;Kim, G. Y.;H. Y. Chae
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.593-599
    • /
    • 2000
  • Accurate quantification of plant physiological properties is often necessary for optimal control of an automated greenhouse production system. Conventional crop growth monitoring systems are usually burdensome, inaccurate, and harmful to crops. A thermal image analysis system was used to accomplish rapid and accurate measurements of physiological-property changes of water-stressed crops. Thermal images were obtained from several species of plants that were placed in a growth chamber. Analyzing the images provided the pattern of temperature changes in a leaf and the amount of differences in the temperature of stressed plants and non-stressed plants.

  • PDF

열영상 정보를 이용한 온실 재배 작물의 수분 스트레스 분석 (Analysis of Water Stress of Greenhouse Crops Using Infrared Thermography)

  • 김기영;류관희;채희연
    • Journal of Biosystems Engineering
    • /
    • 제24권5호
    • /
    • pp.439-444
    • /
    • 1999
  • Automated greenhouse production systems often require crop growth monitoring involving accurate quantification of plant physiological properties. Conventional methods are usually burdensome, inaccurate, and harmful to crops. A thermal image analysis system can accomplish rapid and accurate measurements of physiological-property changes of stressed crops. In this research a thermal imaging system was used to measure the leaf-temperature changes of several crops according to water deficit. Thermal images were obtained from lettuce, cucumber, pepper, and chinese cabbage plants. Results showed that there were significant differences in the temperature of stressed plants and non-stressed plants. The temperature differences between these two group of plants were 0.7 to 3$^{\circ}C$ according to species.

  • PDF

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.