• Title/Summary/Keyword: imaging property

Search Result 154, Processing Time 0.025 seconds

A study of the High Sensitive Nonsilver Halide Imaging Material( I ) - Purification of CuPc pigment by a train sublimation technique and preparation of CuPc pigment thin films and it's application for electrophotoconductor - (고감도 비은염 화상재료 개발연구( I ) - CuPc안료의 승화정제 및 전해석출법에 의한 CuPc 박막의 제작과 전자사진감광체에의 응용)

  • 이상남
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.8 no.1
    • /
    • pp.53-70
    • /
    • 1990
  • It is well known that viologens such as 1.1 - disubstituted 4, 4` - bipyridinium salts and those used as redox indicator, herbicide and electrocheromic display device because those possess the lowest redox potential in any organic system. Viologen salts produced reversible high blue color under the influence of radical cation by photoreduction This study is related to the synthesis of viologen derivatives and the photoreduction property in water solution stats and the polar aprotic polyvinylpyrrolidone(PVP) matrix.

  • PDF

ITERATIVE REWEIGHTED ALGORITHM FOR NON-CONVEX POISSONIAN IMAGE RESTORATION MODEL

  • Jeong, Taeuk;Jung, Yoon Mo;Yun, Sangwoon
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.3
    • /
    • pp.719-734
    • /
    • 2018
  • An image restoration problem with Poisson noise arises in many applications of medical imaging, astronomy, and microscopy. To overcome ill-posedness, Total Variation (TV) model is commonly used owing to edge preserving property. Since staircase artifacts are observed in restored smooth regions, higher-order TV regularization is introduced. However, sharpness of edges in the image is also attenuated. To compromise benefits of TV and higher-order TV, the weighted sum of the non-convex TV and non-convex higher order TV is used as a regularizer in the proposed variational model. The proposed model is non-convex and non-smooth, and so it is very challenging to solve the model. We propose an iterative reweighted algorithm with the proximal linearized alternating direction method of multipliers to solve the proposed model and study convergence properties of the algorithm.

Suppression of Speckle in ultrasonic image by Phase Filtering (위상필터를 사용한 초음파 영사에서의 반점 제거)

  • Kim, D.;Greenleaf, J.F.;Oh, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.5-10
    • /
    • 1990
  • The object detection capabilities of ultrasonic imaging systems are limited by the ability of the detection process to distinguish the resolved object signals from backscattered speckle noise. It has been shown that the phase component of the Fourier transform of the speckle noise is random. Based on this property. we propose a new algorithm for distinguishing between speckle and specular targets. The proposed algorithm is implemented by taking the Fourier transform of the received signal, low-pass filtering the phase, and taking the inverse Fourier transform of the filtered phase to enhance specular reflectors and reduce speckle in the image. Simulations and experiments using phantoms confirm the algorithm yielding significant reduction of speckle noise.

  • PDF

Polarity Probing Two-Photon Fluorophores Based on [2.2]Paracyclophane

  • Woo, Han-Young;Korystov, Dmitry;Jin, Young-Eup;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2253-2260
    • /
    • 2007
  • A series of tetra donor substituted [2.2]paracyclophane-based two-photon absorption (TPA) fluorophores were synthesized in neutral and cationic forms. The imaging activity of overall set of fluorophores was studied by the two-photon induced fluorescence (TPIF) method in a range of solvents. We also measured a clear progression toward a longer photoluminescence lifetime with increasing solvent polarity (intrinsic photoluminescence lifetime, τi: ~2 ns in toluene → 12-16 ns in water). The paracyclophane fluorophores with this unique property can be utilized as an optical polarity probe for the biomolecular substrates. The combined measurement of the two-photon fluorescence microscopy (TPM) cell image and TPIF lifetime can give us a better understanding of the biological processes and local environments in the cells.

Flexure hinge mechanism having amplified rectilinear motion for confocal scanning microscopy using optical section

  • Kwon, Oh-Kyu;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.162.6-162
    • /
    • 2001
  • Confocal scanning microscopy (CSM) is an important instrument in a wide variety of imaging applications because of its ability to provide three-dimensional images of thick, volume specimens. The mechanism for two-dimensional beam scanning and optical sectioning has an important roe in CSM as the three-dimensional profiler. This optical sectioning property arises from the use of a point detector, which serves to attenuate the signals from out-of-focus. The intensity profile for the open loop scanning should be matched with its response for the standard. The non-linearity can be minimized with the optical sectioning or the optical probe of the closed loop control. This paper shows the mathematical expression of the light such as the extinction curve in the optical fields of system using AO deflector, the axial/lateral response experimentally when the error sources change, and the methods of optical sectioning. Thorough design of optical sectioner is crucial to the success of CSM in the field ...

  • PDF

THE RELATIVE IMPORTANCE OF NON-NEWTONIAN CHARACTERISTICS OF BLOOD IN THE HEMODYNAMICS OF THE CAROTID BIFURCATION (경동맥 혈류유동에서의 혈액의 비뉴우토니안 특성의 상대적 중요성 해석)

  • Lee, S.W.;Steinman, D.A.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.181-185
    • /
    • 2008
  • In this study, we attempted to quantify the relative importance of assumptions regarding blood rheology. Three patient-specific carotid bifurcation geometries and time-varying flow rates were obtained using magnetic resonance imaging. For each subject, CFD simulations were carried out assuming two different non-Newtonian rheology models Carreau and Ballyk models) and rescaled Newtonian viscosities based on characteristic shear rates to account for the shear-thinning property of blood. The sensitivity of WSS and oscillatory shear index (OSI) were contextualized with respect to the reproducibility of the reconstructed geometry and to assumptions regarding the inlet boundary conditions. We conclude that the assumption of Newtonian fluid is reasonable for studies aimed at quantifying the distribution of WSS-based extrema in an image-based CFD model of carotid bifurcation.

  • PDF

THE RELATIVE IMPORTANCE OF NON-NEWTONIAN CHARACTERISTICS OF BLOOD IN THE HEMODYNAMICS OF THE CAROTID BIFURCATION (경동맥 혈류유동에서의 혈액의 비뉴우토니안 특성의 상대적 중요성 해석)

  • Lee, S.W.;Steinman, D.A.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.181-185
    • /
    • 2008
  • In this study, we attempted to quantify the relative importance of assumptions regarding blood rheology. Three patient-specific carotid bifurcation geometries and time-varying flow rates were obtained using magnetic resonance imaging. For each subject, CFD simulations were carried out assuming two different non-Newtonian rheology models (Carreau and Ballyk models) and rescaled Newtonian viscosities based on characteristic shear rates to account for the shear-thinning property of blood. The sensitivity of WSS and oscillatory shear index (OSI) were contextualized with respect to the reproducibility of the reconstructed geometry and to assumptions regarding the inlet boundary conditions. We conclude that the assumption of Newtonian fluid is reasonable for studies aimed at quantifying the distribution of WSS-based extrema in an image-based CFD model of carotid bifurcation.

  • PDF

Hybrid Time-Reversal Method for Structural Health Monitoring (구조물 건전성 모니터링을 위한 하이브리드 시간-반전기법)

  • Lee, U-Sik;Kim, Dae-Hwan;Jun, Yong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.546-548
    • /
    • 2010
  • This paper proposes a new baseline-free TR-based SHM method in which the time-reversal (TR) property of the guided Lamb waves is utilized. The new TR-based SHM method has two distinct features when compared with the other existing SHM techniques: (1) The measurement- based backward TR process is replaced by the computation-based process (2) In place of the comparison method most commonly used for SHM, the TOF information of the damage signal extracted from the reconstructed signal is utilized for the damage diagnosis. For the damage diagnosis, the imaging method is adopted to efficiently detect damage by representing the damage as an image. The proposed TR-based SHM technique is then validated through the damage diagnosis experiment for an aluminum plate with a damage at different locations.

  • PDF

POLARIZATION AND POLARIMETRY: A REVIEW

  • Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.1
    • /
    • pp.15-39
    • /
    • 2014
  • Polarization is a basic property of light and is fundamentally linked to the internal geometry of a source of radiation. Polarimetry complements photometric, spectroscopic, and imaging analyses of sources of radiation and has made possible multiple astrophysical discoveries. In this article I review (i) the physical basics of polarization: electromagnetic waves, photons, and parameterizations; (ii) astrophysical sources of polarization: scattering, synchrotron radiation, active media, and the Zeeman, Goldreich-Kylafis, and Hanle effects, as well as interactions between polarization and matter (like birefringence, Faraday rotation, or the Chandrasekhar-Fermi effect); (iii) observational methodology: on-sky geometry, influence of atmosphere and instrumental polarization, polarization statistics, and observational techniques for radio, optical, and $X/{\gamma}$ wavelengths; and (iv) science cases for astronomical polarimetry: solar and stellar physics, planetary system bodies, interstellar matter, astrobiology, astronomical masers, pulsars, galactic magnetic fields, gamma-ray bursts, active galactic nuclei, and cosmic microwave background radiation.

3-Dimensional Subsurface Imaging Using Geostatistics (공간통계학을 이용한 3차원 지하영상화)

  • Shon, Ho-Woong;Lee, Kang-Won;Park, Eun-Ho
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2009.04a
    • /
    • pp.151-156
    • /
    • 2009
  • Forward modelling of ground penetrating radar (GPR) data is implemented using a new finite element ray tracing technique. The method is different from conventional ray tracing techniques in that the radar cross section of buried targets, the effective area of the receiving antenna, and the attenuation along the raypath are computed. The forward models are used to understand radar signatures measured across various ground structures which are important in detecting engineering hazards at construction sites, void spaces beneath simulated road beds, as well as a learning tool to avoid pitfalls in radargram interpretation. Forward modelling of radar data also can be used in predicting possible structures present at cultural property sites.

  • PDF