• Title/Summary/Keyword: imaging infrared

Search Result 769, Processing Time 0.028 seconds

The Evaluation of Non-Ionizing Radiation (Near-Infrared Radiation) based Medical Imaging Application : Diabetes Foot (비전리 방사선 (근적외선) 기반 의료영상 활용 가능성 평가: 당뇨발)

  • Jung, Young-Jin;Shin, Cheol-Won;Ahn, Sung-Min;Hong, Jun-Yong;Ahn, Yun-Jin;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.399-406
    • /
    • 2016
  • Near-infrared radiation (NIR) is non-ionizing, non-invasive, and deep tissue penetration in biological material, thereby increasing research interests as a medical imaging technique in the world. However, the use of current near-infrared medical image is extremely limited in Korea (ROK) since it is not well known among radiologic technologists and radiological researchers. Therefore to strengthen the knowledge for NIR medical imaging is necessary so as to prepare a qualified radiological professionals to serve medical images in high-quality on the clinical sites. In this study, an overview of the features and principles of NIR imaging was demonstrated. The latest research topics and worldwide research trends were introduced for radiologic technologist to reinforce their technical skills. In particular, wound care and diabetic foot which have high feasibility for clinical translation were introduced in order to contribute to accelerating NIR research for developing the field of radiological science.

Imaging Evaluation of Peritoneal Metastasis: Current and Promising Techniques

  • Chen Fu;Bangxing Zhang;Tiankang Guo;Junliang Li
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.86-102
    • /
    • 2024
  • Early diagnosis, accurate assessment, and localization of peritoneal metastasis (PM) are essential for the selection of appropriate treatments and surgical guidance. However, available imaging modalities (computed tomography [CT], conventional magnetic resonance imaging [MRI], and 18fluorodeoxyglucose positron emission tomography [PET]/CT) have limitations. The advent of new imaging techniques and novel molecular imaging agents have revealed molecular processes in the tumor microenvironment as an application for the early diagnosis and assessment of PM as well as real-time guided surgical resection, which has changed clinical management. In contrast to clinical imaging, which is purely qualitative and subjective for interpreting macroscopic structures, radiomics and artificial intelligence (AI) capitalize on high-dimensional numerical data from images that may reflect tumor pathophysiology. A predictive model can be used to predict the occurrence, recurrence, and prognosis of PM, thereby avoiding unnecessary exploratory surgeries. This review summarizes the role and status of different imaging techniques, especially new imaging strategies such as spectral photon-counting CT, fibroblast activation protein inhibitor (FAPI) PET/CT, near-infrared fluorescence imaging, and PET/MRI, for early diagnosis, assessment of surgical indications, and recurrence monitoring in patients with PM. The clinical applications, limitations, and solutions for fluorescence imaging, radiomics, and AI are also discussed.

TEST MODEL OF MILLIMETER-WAVE IMAGING RADIOMETER EQUIPMENT (MIRAE)

  • Lee, Ho-Jin;Kim, Won-Gyum;Seong, Jin-Taek;Kim, Dae-Suk;Na, Kyoung-Tae;Jung, Min-Kyoo;Chang, Yu-Shin;Kim, Soon-Tae;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.365-368
    • /
    • 2007
  • Millimeter-wave (MMW) imaging radiometer systems have an attractive advantage to obtain an image through low visibility weather conditions such as fog, clouds and light rain compared with visible and infrared imaging systems. Many countries have developed a various kinds of MMW imaging radiometers for the aim of low cost and high performance. In Korea, Millimeter-wave Imaging RAdiometer Equipment (MIRAE) has been developed since the end of 2006. Recently the development of some modules was finished for the test model. This paper describes the design and development of the MIRAE. In addition, the test results of its manufactured modules are presented.

  • PDF

A Study on Characteristics Analysis of Multichannel Filter Module for Near-infrared Fluorescence Imaging (근적외선 형광 이미징 영상 구현을 위한 다채널 필터 모듈 특성분석 연구)

  • Choi, Jinsoo;Cho, Sang Uk;Kim, Doo-In;Lee, Hak-Guen;Choi, Hak Soo;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, development of multichannel filter module and characteristic evaluation for bio imaging were studied. The filter module was fabricated in order to realize near infrared fluorescence imaging of 700 nm and 800 nm wavelength ranges, and contrast imaging analysis for characteristic evaluation of the filter module was studied through signal to back ground ratio (SBR), controlled by parameters such as magnification, exposure, gain. Furthermore, phantoms, which are biomimetic tissue with equal optical properties of kidney and liver, were fabricated to study characteristics of both filter module depending on thickness and exposure amount of light source for bio imaging analysis. The fabricated filter module has more than 4 of SBR difference despite changes of magnification, exposure, gain, and in the case of the kidney phantom and the liver phantom, contrast imaging of more than 4 of SBR was confirmed on 50 mA, 60 mA exposure amount of light source respectively.

IMS High-z Quasar Survey - Faint z~6 Quasar Candidates in IMS Fields

  • Kim, Yongjung;Im, Myungshin;Jeon, Yiseul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.72.4-73
    • /
    • 2015
  • Over the last decade, more than 50 quasars have been discovered at redshift about 6 when reionization of the universe occurred. However, most of them are luminous quasars (zAB < 21 mag), implying that such a biased quasar sample, which cannot represent the entire population of quasars at z~6, is not enough to understand the properties of quasars in the early universe. Recently, we have been performing the Infrared Medium-deep Survey (IMS), a moderately wide (120 deg2) and deep (JAB ~ 22.5 - 23 mag) near-infrared imaging survey. Combining this with the optical (ugriz) imaging data from the CFHT Legacy Survey (CFHTLS), we have identified more than 10 faint quasar candidates at z~6 in the IMS field by using multiple color selection criteria. From now on, we will perform spectroscopic confirmations of these faint quasar candidates with IMACS on the Magellan Baade Telescope at Las Campanas Observatory and GMOS on the Gemini South Telescope at Gemini Observatory. The confirmed quasars will be used to constrain the faint-end slope of the quasar luminosity function at z~6 and calculate the ratio of quasar ionizing flux to required flux for reionization of the universe. Moreover, these confirmed quasars will be followed up with near-infrared spectroscopy to determine their black hole masses and Eddington ratios to check the rapidness of their growth.

  • PDF

Active Infrared Thermography for Visualizing Subsurface Micro Voids in an Epoxy Molding Compound

  • Yang, Jinyeol;Hwang, Soonkyu;Choi, Jaemook;Sohn, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.106-114
    • /
    • 2017
  • This paper presents an automated subsurface micro void detection technique based on pulsed infrared thermography for inspecting epoxy molding compounds (EMC) used in electronic device packaging. Subsurface micro voids are first detected and visualized by extracting a lock-in amplitude image from raw thermal images. Binary imaging follows to achieve better visualization of subsurface micro voids. A median filter is then applied for removing sparse noise components. The performance of the proposed technique is tested using 36 EMC samples, which have subsurface (below $150{\mu}m{\sim}300{\mu}m$ from the inspection surface) micro voids ($150{\mu}m{\sim}300{\mu}m$ in diameter). The experimental results show that the subsurface micro voids can be successfully detected without causing any damage to the EMC samples, making it suitable for automated online inspection.

In vivo Dendritic Cell Migration Tracking Using Near-infrared (NIR) Imaging (Near-infrared (NIR) 영상기법을 이용한 생체 내 수지상세포의 이동)

  • Lee, Jun-Ho;Jung, Nam-Chul;Lee, Eun Gae;Lim, Dae-Seog
    • KSBB Journal
    • /
    • v.27 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Matured dendritic cells (DCs) begin migration with their release from the bone marrow (BM) into the blood and subsequent traffic into peripheral lymphoid and non-lymphoid tissues. Throughout this long movement, migrating DCs must apply specialized skills to reach their target destination. Non-invasive in vivo cell-tracking techniques are necessary to advance immune cell-based therapies. In this study, we used a DiD cell-tracking solution for in vivo dendritic cell tracking in naive mice. We tracked DiD (non-invasive fluorescence dye)-labeled mature dendritic cells using the Near Infrared (NIR) imaging system in normal mice. We examined the immunophenotype of DiD-labeled cells compared with non-labelled mature DCs, and obtained time-serial images of NIR-DC trafficking after mouse footpad injection. In conclusion, we confirmed that DiD-labeled DCs migrated into the popliteal lymph node 24 h after the footpad injection. Here, these data suggested that the cell tracking system with the stable fluorescence dye DiD was useful as a cell tracking tool to advance dendritic cell-based immunotherapy.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

Development of Near Infrared Radiation Image Board for Performace Improvement of Grain Sorter (곡물선별기의 선별력 향상을 위한 근거리적외선 영상보드 개발)

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Currently, most of the grain sorter uses CCD optic camera to find defective products. The aim of this paper is to use the CCD camera, and aim for improving the sorting power of the grain separator by using NIR(Near Infrared Radiation) sensor based on moisture content measurement algorithm. We intend to develop a system to develop an NFC imaging system in real time by developing an NIR imaging system and developing the grain sorter system that is considered to be defective in real time by checking the internal moisture content of the raw material in the real time.

  • PDF

Study on the Thermal and Electrical Conductivity Properties of Titanium-sputtered Materials

  • Han, Hye Ree
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.3
    • /
    • pp.530-544
    • /
    • 2022
  • Titanium exhibits substantial corrosion resistance, strength, and ductility, with a specific gravity of approximately 4.5 and a melting point of approximately 1800℃. It is currently used in aircraft parts and space development. This study considered the thermal characteristics, stealth effects of infrared thermal imaging cameras, electromagnetic shielding, and electrical conductivity of Ti-sputtered materials. Base materials of different densities and types were treated using titanium sputtering. Infrared thermal imaging showed a better stealth effect when the titanium layer was directed toward the outside. The film sample presented a better stealth effect than the fabrics did. In each of the samples subjected to titanium sputtering, when the titanium layer was directed outward, the untreated sample or exposed titanium layer showed surface temperatures lower than those of the samples with the titanium layer oriented toward the heat source. Additionally, after the titanium sputtering treatment, the films conducted electricity (low resistance) better than the fabrics did. All titanium-sputtered specimens presented reduced electromagnetic wave transmission and significantly reduced infrared transmission. These results are expected to apply to military uniforms (soldiers' protective clothing to gain the upper hand on the battlefield), medical sensors, multifunctional intelligent textiles and etc.