• Title/Summary/Keyword: image motion compensation

Search Result 154, Processing Time 0.025 seconds

Motion Blur Reduction in LCDs

  • Hong, Sun-Kwang;Oh, Jae-Ho;Park, Po-Yun;Park, Jin-Hyeok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1108-1110
    • /
    • 2004
  • LCDs show motion image blur due to slow response time and a hold-type driving method. In this paper, we investigate motion blur phenomena and quantitatively show that the motion blur can be significantly reduced through a combination of dynamic capacitance compensation (DCC) and black data insertion.

  • PDF

Analysis of Affine Motion Compensation for Light Field Image Compression (라이트필드 영상 압축을 위한 Affine 움직임 보상 분석)

  • Huu, Thuc Nguyen;Duong, Vinh Van;Xu, Motong;Jeon, Byeungwoo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.06a
    • /
    • pp.216-217
    • /
    • 2019
  • Light Field (LF) image can be understood as a set of images captured by a multi-view camera array at the same time. The changes among views can be modeled by a general motion model such as affine motion model. In this paper, we study the impact of affine coding tool of Versatile Video Coding (VVC) on LF image compression. Our experimental results show a small contribution by affine coding tool in overall LF image compression of roughly 0.2% - 0.4%.

  • PDF

An image sequence coding using motion-compensated transform technique based on the sub-band decomposition (움직임 보상 기법과 분할 대역 기법을 사용한 동영상 부호화 기법)

  • Paek, Hoon;Kim, Rin-Chul;Lee, Sang-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • In this paper, by combining the motion compensated transform coding with the sub-band decomposition technique, we present a motion compensated sub-band coding technique(MCSBC) for image sequence coding. Several problems related to the MCSBC, such as a scheme for motion compensation in each sub-band and the efficient VWL coding of the DCT coefficients in each sub-band are discussed. For an efficient coding, the motion estimation and compensation is performed only on the LL sub-band, but the discrete cosine transform(DCT) is employed to encode all sub-bands in our approach. Then, the transform coefficients in each sub-band are scanned in a different manner depending on the energy distributions in the DCT domain, and coded by using separate 2-D Huffman code tables, which are optimized to the probability distributions in the DCT domain, and coded by using separate 2-D Huffman code tables, which are optimized to the probability distribution of each sub-band. The performance of the proposed MCSBC technique is intensively examined by computer simulations on the HDTV image sequences. The simulation results reveal that the proposed MCSBC technique outperforms other coding techniques, especially the well-known motion compensated transform coding technique by about 1.5dB, in terms of the average peak signal to noise ratio.

  • PDF

Susceptibility Weighted Imaging of the Cervical Spinal Cord with Compensation of Respiratory-Induced Artifact

  • Lee, Hongpyo;Nam, Yoonho;Gho, Sung-Min;Han, Dongyeob;Kim, Eung Yeop;Lee, Sheen-Woo;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.209-217
    • /
    • 2018
  • Purpose: The objective of this study was to obtain improved susceptibility weighted images (SWI) of the cervical spinal cord using respiratory-induced artifact compensation. Materials and Methods: The artifact from $B_0$ fluctuations by respiration could be compensated using a double navigator echo approach. The two navigators were inserted in an SWI sequence before and after the image readouts. The $B_0$ fluctuation was measured by each navigator echoes, and the inverse of the fluctuation was applied to eliminate the artifact from fluctuation. The degree of compensation was quantified using a quality index (QI) term for compensated imaging using each navigator. Also, the effect of compensation was analyzed according to the position of the spinal cord using QI values. Results: Compensation using navigator echo gave the improved visualization of SWI in cervical spinal cord compared to non-compensated images. Before compensation, images were influenced by artificial noise from motion in both the superior (QI = 0.031) and inferior (QI = 0.043) regions. In most parts of the superior regions, the second navigator resulted in better quality (QI = 0.024, P < 0.01) compared to the first navigator, but in the inferior regions the first navigator showed better quality (QI = 0.033, P < 0.01) after correction. Conclusion: Motion compensation using a double navigator method can increase the improvement of the SWI in the cervical spinal cord. The proposed method makes SWI a useful tool for the diagnosis of spinal cord injury by reducing respiratory-induced artifact.

Fast Video Stabilization Method Using Integral Image (적분 영상을 이용한 고속 비디오 안정화 기법)

  • Kwon, Young-Man;Lim, Myung-Jae;Oh, Byung-Hun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.13-20
    • /
    • 2010
  • We proposed a new technique to perform fast video stabilization using integral image in this article. In the proposed technique, it evaluate local and global motion by the block matching using the generated integral image for each frame and compensate the motion like jitter. We made the various experimental jitter patterns to evaluate the effectiveness of the proposed technique and evaluated stabilization capability and execution time with the existing ones. Through the experiment, we found that the execution time of proposed technique was faster than that of existing techniques and the compensation of jitter was well done.

A Study on the Rotational Motion Compensation Method for ISAR Imaging (ISAR 영상 형성을 위한 회전운동보상 기법 연구)

  • Kang, Byung-Soo;Bae, Ji-Hoon;Chung, Sung-Eun;Kim, Chan-Hong;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • In this paper, we propose a inverse synthetic aperture radar(ISAR) rotational motion compensation(RMC) method to remove residual blurring caused by non-uniform rotational motion of a target. First, a range bin having an isolated scatterer is selected. Next, polynomial phase signal in the selected range bin is estimated by using both Fourier transform(FT) and polynomial-phase transform(PPT). Finally, a new slow time variable that uniformly samples radar signal along the aspect angle directions is defined by using the estimated phase signal, and we interpolate radar signal in terms of the new time variable. As a result, rotational motion to blurr ISAR images is removed, and focused ISAR images are obtained. Simulation results using battleship model validate the robustness and effectiveness of our proposed RMC method.

A Study on Rotational Motion Compensation Method for Bistatic ISAR Imaging (바이스태틱 ISAR 영상 형성을 위한 회전운동보상 기법 연구)

  • Kang, Byung-Soo;Ryu, Bo-Hyun;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.670-677
    • /
    • 2017
  • In this paper, we propose a rotational motion compensation(RMC) for bistatic inverse synthetic aperture radar(Bi-ISAR) imaging. For this purpose, geometry-error, caused by changes of bistatic-angle, is removed using known position information of a transmitter, a receiver, and target trajectories. Next, RMC is performed to compensate non-uniform rotational motion error by reformatting radar signal in terms of a newly defined slow time variable that converts non-uniform rotational motion into uniform one. Simulation results using an aircraft model composed of ideal point scatterers validate the efficacy of the proposed Bi-ISAR RMC method.

A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy (IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템)

  • Kim, Yoon-Jong;Yoon, Uei-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

A Stabilization Method for Rotated and Translated Images (회전 및 병진 흔들림 영상의 안정화 기법)

  • Seok Ho-Dong;Lyou Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.8
    • /
    • pp.810-817
    • /
    • 2006
  • This paper presents a rotational motion estimation and correction technique for digital image stabilization. An equivalent rotation model is derived so as to accommodate a combined rotational and the translational motion. Thanks to this simplification, the suggested estimation algorithm can directly find the rotational center using geometric characteristic of local motion vectors instead of using searching method. And we also present recursive version of frame to reference algorithm(FRA) for the real time implementation. The proposed DIS system does not require time consuming parameter searching process, while showing comparatively good performance compared with the previous ones. To show the effectiveness of the DIS scheme, the algorithm has been implemented on the DSP based hardware system and experimental results are also discussed.

Limiting Motion Search Range for the Pseudo Video Sequence-based Light Field Image Coding (유사 비디오 시퀀스 기반의 라이트필드 영상 부호화를 위한 움직임 탐색 영역 제한)

  • Yim, Jonghoon;Duong, Vinh Van;Huu, Thuc Nguyen;Jeon, Byeungwoo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.182-183
    • /
    • 2022
  • The large data volume of light field (LF) image has motivated much research on how to compress the data volume more efficiently. One of the approaches is to compress LF images after representing them in the form of pseudo video sequence. In this way, the pseudo temporal redundancy between views can be exploited by motion estimation and compensation. Based on our observation that images obtained by LF cameras have small range of disparity values between adjacent views, we propose to limit the motion search range to reduce the time complexity of motion estimation. Our experimental results show that a smaller motion search range reduces the encoding time while not affecting the bitrate of H.266/VVC much.

  • PDF