• Title/Summary/Keyword: image measurement

Search Result 3,103, Processing Time 0.031 seconds

An Implementation of OTB Extension to Produce TOA and TOC Reflectance of LANDSAT-8 OLI Images and Its Product Verification Using RadCalNet RVUS Data (Landsat-8 OLI 영상정보의 대기 및 지표반사도 산출을 위한 OTB Extension 구현과 RadCalNet RVUS 자료를 이용한 성과검증)

  • Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.449-461
    • /
    • 2021
  • Analysis Ready Data (ARD) for optical satellite images represents a pre-processed product by applying spectral characteristics and viewing parameters for each sensor. The atmospheric correction is one of the fundamental and complicated topics, which helps to produce Top-of-Atmosphere (TOA) and Top-of-Canopy (TOC) reflectance from multi-spectral image sets. Most remote sensing software provides algorithms or processing schemes dedicated to those corrections of the Landsat-8 OLI sensors. Furthermore, Google Earth Engine (GEE), provides direct access to Landsat reflectance products, USGS-based ARD (USGS-ARD), on the cloud environment. We implemented the Orfeo ToolBox (OTB) atmospheric correction extension, an open-source remote sensing software for manipulating and analyzing high-resolution satellite images. This is the first tool because OTB has not provided calibration modules for any Landsat sensors. Using this extension software, we conducted the absolute atmospheric correction on the Landsat-8 OLI images of Railroad Valley, United States (RVUS) to validate their reflectance products using reflectance data sets of RVUS in the RadCalNet portal. The results showed that the reflectance products using the OTB extension for Landsat revealed a difference by less than 5% compared to RadCalNet RVUS data. In addition, we performed a comparative analysis with reflectance products obtained from other open-source tools such as a QGIS semi-automatic classification plugin and SAGA, besides USGS-ARD products. The reflectance products by the OTB extension showed a high consistency to those of USGS-ARD within the acceptable level in the measurement data range of the RadCalNet RVUS, compared to those of the other two open-source tools. In this study, the verification of the atmospheric calibration processor in OTB extension was carried out, and it proved the application possibility for other satellite sensors in the Compact Advanced Satellite (CAS)-500 or new optical satellites.

Correlation Analysis Between 3D Kidneys Measurements and Abdominal Obesity Level in Computed Tomography (전산화단층영상에서 콩팥 3차원 영상 계측치와 복부 비만도 간의 상관관계 분석)

  • Ji-Yeong Kim;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.315-325
    • /
    • 2023
  • The purpose of this study was to predict abdominal obesity with 3-Dimensional computed tomography (3D CT) measurements of kidneys by analyzing the correlation between kidney sizes and abdominal obesity level. The subjects were 178 healthy adults without underlying diseases who had a comprehensive health examination at the Health Medical Center of Jesus Hospital in Jeonju. Abdominal obesity was measured by CT cross-sectional image at the level of the umbilicus and divided into visceral fat area, subcutaneous fat area, visceral fat/total fat ratio. The average comparison of kidney sizes classified according to abdominal obesity were performed through one-way analysis of variance (ANOVA) and Scheffe test. Pearson correlation analysis was performed to correlate all measurement values. The results of kidney size ANOVA analysis according to abdominal obesity were as follows. The means of kidney measurements according to visceral fat classification were significantly different in all kidney measurements (p<0.05). And in case of subcutaneous fat classification, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in the right kidney width (p<0.05). In case of visceral fat area/total fat area ratio, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in both kidneys width (p<0.05). Pearson correlation between kidneys measurements and CT abdominal obesity showed that visceral fat area had the highest correlation with the left kidney width measured by 3D CT (r=0.467) and subcutaneous fat area had correlation with the right kidney width measured by 3D CT (r=0.249). The visceral fat area/total fat area ratio had correlation with the left kidney width measured by 3D CT (r=0.291).

Comparative Study on the Carbon Stock Changes Measurement Methodologies of Perennial Woody Crops-focusing on Overseas Cases (다년생 목본작물의 탄소축적 변화량 산정방법론 비교 연구-해외사례를 중심으로)

  • Hae-In Lee;Yong-Ju Lee;Kyeong-Hak Lee;Chang-Bae Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.258-266
    • /
    • 2023
  • This study analyzed methodologies for estimating carbon stocks of perennial woody crops and the research cases in overseas countries. As a result, we found that Australia, Bulgaria, Canada, and Japan are using the stock-difference method, while Austria, Denmark, and Germany are estimating the change in the carbon stock based on the gain-loss method. In some overseas countries, the researches were conducted on estimating the carbon stock change using image data as tier 3 phase beyond the research developing country-specific factors as tier 2 phase. In South Korea, convergence studies as the third stage were conducted in forestry field, but advanced research in the agricultural field is at the beginning stage. Based on these results, we suggest directions for the following four future researches: 1) securing national-specific factors related to emissions and removals in the agricultural field through the development of allometric equation and carbon conversion factors for perennial woody crops to improve the completeness of emission and removals statistics, 2) implementing policy studies on the cultivation area calculation refinement with fruit tree-biomass-based maturity, 3) developing a more advanced estimation technique for perennial woody crops in the agricultural sector using allometric equation and remote sensing techniques based on the agricultural and forestry satellite scheduled to be launched in 2025, and to establish a matrix and monitoring system for perennial woody crop cultivation areas in the agricultural sector, Lastly, 4) estimating soil carbon stocks change, which is currently estimated by treating all agricultural areas as one, by sub-land classification to implement a dynamic carbon cycle model. This study suggests a detailed guideline and advanced methods of carbon stock change calculation for perennial woody crops, which supports 2050 Carbon Neutral Strategy of Ministry of Agriculture, Food, and Rural Affairs and activate related research in agricultural sector.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient (비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가)

  • Park, So-Yeon;Ahn, Jong-Ho;Suh, Jung-Min;Kim, Yung-Il;Kim, Jin-Man;Choi, Byung-Ki;Pyo, Hong-Ryul;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2012
  • Purpose: It is essential to minimize the movement of tumor due to respiratory movement at the time of respiration controlled radiotherapy of non-small cell lung cancer patient. Accordingly, this Study aims to evaluate the usefulness of restricted respiratory period by comparing and analyzing the treatment plans that apply free and restricted respiration period respectively. Materials and Methods: After having conducted training on 9 non-small cell lung cancer patients (tumor n=10) from April to December 2011 by using 'signal monitored-breathing (guided- breathing)' method for the 'free respiratory period' measured on the basis of the regular respiratory period of the patents and 'restricted respiratory period' that was intentionally reduced, total of 10 CT images for each of the respiration phases were acquired by carrying out 4D CT for treatment planning purpose by using RPM and 4-dimensional computed tomography simulator. Visual gross tumor volume (GTV) and internal target volume (ITV) that each of the observer 1 and observer 2 has set were measured and compared on the CT image of each respiratory interval. Moreover, the amplitude of movement of tumor was measured by measuring the center of mass (COM) at the phase of 0% which is the end-inspiration (EI) and at the phase of 50% which is the end-exhalation (EE). In addition, both observers established treatment plan that applied the 2 respiratory periods, and mean dose to normal lung (MDTNL) was compared and analyzed through dose-volume histogram (DVH). Moreover, normal tissue complication probability (NTCP) of the normal lung volume was compared by using dose-volume histogram analysis program (DVH analyzer v.1) and statistical analysis was performed in order to carry out quantitative evaluation of the measured data. Results: As the result of the analysis of the treatment plan that applied the 'restricted respiratory period' of the observer 1 and observer 2, there was reduction rate of 38.75% in the 3-dimensional direction movement of the tumor in comparison to the 'free respiratory period' in the case of the observer 1, while there reduction rate was 41.10% in the case of the observer 2. The results of measurement and comparison of the volumes, GTV and ITV, there was reduction rate of $14.96{\pm}9.44%$ for observer 1 and $19.86{\pm}10.62%$ for observer 2 in the case of GTV, while there was reduction rate of $8.91{\pm}5.91%$ for observer 1 and $15.52{\pm}9.01%$ for observer 2 in the case of ITV. The results of analysis and comparison of MDTNL and NTCP illustrated the reduction rate of MDTNL $3.98{\pm}5.62%$ for observer 1 and $7.62{\pm}10.29%$ for observer 2 in the case of MDTNL, while there was reduction rate of $21.70{\pm}28.27%$ for observer 1 and $37.83{\pm}49.93%$ for observer 2 in the case of NTCP. In addition, the results of analysis of correlation between the resultant values of the 2 observers, while there was significant difference between the observers for the 'free respiratory period', there was no significantly different reduction rates between the observers for 'restricted respiratory period. Conclusion: It was possible to verify the usefulness and appropriateness of 'restricted respiratory period' at the time of respiration controlled radiotherapy on non-small cell lung cancer patient as the treatment plan that applied 'restricted respiratory period' illustrated relative reduction in the evaluation factors in comparison to the 'free respiratory period.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

The Measurement of Sensitivity and Comparative Analysis of Simplified Quantitation Methods to Measure Dopamine Transporters Using [I-123]IPT Pharmacokinetic Computer Simulations ([I-123]IPT 약역학 컴퓨터시뮬레이션을 이용한 민감도 측정 및 간편화된 운반체 정량분석 방법들의 비교분석 연구)

  • Son, Hye-Kyung;Nha, Sang-Kyun;Lee, Hee-Kyung;Kim, Hee-Joung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.19-29
    • /
    • 1997
  • Recently, [I-123]IPT SPECT has been used for early diagnosis of Parkinson's patients(PP) by imaging dopamine transporters. The dynamic time activity curves in basal ganglia(BG) and occipital cortex(OCC) without blood samples were obtained for 2 hours. These data were then used to measure dopamine transporters by operationally defined ratio methods of (BG-OCC)/OCC at 2 hrs, binding potential $R_v=k_3/k_4$ using graphic method or $R_A$= (ABBG-ABOCC)/ABOCC for 2 hrs, where ABBG represents accumulated binding activity in basal ganglia(${\int}^{120min}_0$ BG(t)dt) and ABOCC represents accumulated binding activity in occipital cortex(${\int}^{120min}_0$ OCC(t)dt). The purpose of this study was to examine the IPT pharmacokinetics and investigate the usefulness of simplified methods of (BG-OCC)/OCC, $R_A$, and $R_v$ which are often assumed that these values reflect the true values of $k_3/k_4$. The rate constants $K_1,\;k_2\;k_3$ and $k_4$ to be used for simulations were derived using [I-123]IPT SPECT and aterialized blood data with a standard three compartmental model. The sensitivities and time activity curves in BG and OCC were computed by changing $K_l$ and $k_3$(only BG) for every 5min over 2 hours. The values (BG-OCC)/OCC, $R_A$, and $R_v$ were then computed from the time activity curves and the linear regression analysis was used to measure the accuracies of these methods. The late constants $K_l,\;k_2\;k_3\;k_4$ at BG and OCC were $1.26{\pm}5.41%,\;0.044{\pm}19.58%,\;0.031{\pm}24.36%,\;0.008{\pm}22.78%$ and $1.36{\pm}4.76%,\;0.170{\pm}6.89%,\;0.007{\pm}23.89%,\;0.007{\pm}45.09%$, respectively. The Sensitivities for ((${\Delta}S/S$)/(${\Delta}k_3/k_3$)) and ((${\Delta}S/S$)/(${\Delta}K_l/K_l$)) at 30min and 120min were measured as (0.19, 0.50) and (0.61, 0,23), respectively. The correlation coefficients and slopes of ((BG-OCC)/OCC, $R_A$, and $R_v$) with $k_3/k_4$ were (0.98, 1.00, 0.99) and (1.76, 0.47, 1.25), respectively. These simulation results indicate that a late [I-123]IPT SPECT image may represent the distribution of the dopamine transporters. Good correlations were shown between (3G-OCC)/OCC, $R_A$ or $R_v$ and true $k_3/k_4$, although the slopes between them were not unity. Pharmacokinetic computer simulations may be a very useful technique in studying dopamine transporter systems.

  • PDF

A Comparative Survey on Misconception and Desire for Physique of College Women in Taegu and Fukuoka (한.일 여대생의 자기 체형 인식 및 체형 불안도에 관한 비교 연구)

  • Hong, Jin-Pyo;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.5
    • /
    • pp.435-442
    • /
    • 2000
  • This study was carried out to investigate misconception for physique and desire for physique of college women in Taegu(412 subjects) and Fukuoka(423 subjects). The data was collected by questionnaire interview and anthropometric measurement. The results were as follows : The mean age, height, weight, and BMI of Taegu subjects were $19.9{\pm}1.2$ years old, $159.6{\pm}4.9cm,\;51.2{\pm}6.0kg\;and\;20.1{\pm}2.2$, respectively. The mean age, height , weight, and BMI of Fukuoka subjects were $18.3{\pm}0.6$ year old, $157.5{\pm}5.0cm,\;53.3{\pm}6.9kg\;and\;21.5{\pm}2.5$, respectively. The average ideal height desired by subjects in Taegu was higher than their real mean height by 5.1cm ; while the average ideal weight desired by subjects was lower than real mean weight by 2.6kg. The average ideal height desired by subjects in Fukuoka was higher than their real mean height by 3.2cm ; while the average ideal weight desired by subjects was lower than real mean weight by 5.4kg. The percentage of Taegu subjects who desired to be slender, be fatty and maintain weight were 70.1%, 7.3%, and 22.6% respectively. The percentage of Fukuoka subjects who desired to be slender, be fatty and maintain weight were 85.3%,2.6% and 12.1% respectively. The rate of misconception for the actual physique was 56.5% in Taegu subjects, and 57.2% In fukuoka subjects. The over estimation rate was higher in subjects desired for slenderness than in others. The adolescent females having a fatty body image in self-consciousness indicated that they felt high social physique anxiousness. Finally, the rate of misconception and the degree of social physique anxiousness were higher in those who had a desire for slenderness.

  • PDF

The Effect of the Quality of Education Service on the Performance of Education Service through Relationship Commitment in Franchise Beauty Academy: Moderating Effect of Trust Level (프랜차이즈 뷰티 아카데미의 교육서비스 품질이 관계 몰입을 통한 교육 서비스 성과에 미치는 영향 연구: 신뢰 수준의 조절효과)

  • Kim, Chang-Bong;Kim, Hee-Su
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.3
    • /
    • pp.193-211
    • /
    • 2021
  • Recently, interest in Korean Wave craze and K-beauty, led by K-pop, is increasing. In addition, the popularity and influence of the domestic beauty service industry has increased, and the economic and cultural ripple effects have been continuously expanding. The need to professional manpower training in response to the demand for manpower due to the growing development of domestic beauty services is emphasized, and the number of trainees who are actual consumers of beauty academy is increasing. Therefore, the purpose of our study is to examine the importance of quality factors of educational services to achieve educational purposes in the educational services provided by the Beauty Academy and the relationship between relationship commitment and educational service performance. Furthermore, it is to draw the importance of administrative support services, educational programs as well as educational service provision activities. However, the research for professional manpower training according to the provision of beauty services is insufficient compared to the development speed of the beauty industry. Therefore, at the present time when beauty service education is emphasized, our study will examine the relationship between relationship commitment and educational service performance based on the quality of education service by the students of domestic beauty academy. The measurement variables set for our study are program, instructor quality, tuition, external service, service fairness, relationship commitment, trust level, and educational service performance. The variables were analyzed and derived through the survey, and the following contents were derived from the empirical analysis. First, the quality of education service provided by the beauty academy, such as program, external service, service fairness, relationship commitment and trust level, had a significant effect on relationship commitment. Educational services provided by the institute, such as the systematicity and diversity of educational programs, enabled students to have a uniform relationship commitment. The quality of education service itself is to learn the expertise necessary for providing beauty service from the standpoint of the students and play an organic role in the relationship with the institute. Second, the moderating effect of trust level between academies and students was significant in the quality of education service and the relationship commitment. This means that students will feel higher level of service quality through the practical trust relationship of the students about the educational services provided by the institute. Based on the results of the empirical analysis, the implications of our study are to find ways to improve the students' ability and satisfaction represented by the results of educational services. This is because the quality of education services provided by the institute called Beauty Academy will have a great impact on the career choice of educational facilities and students. The characteristics of consistency, convenience, and knowledge orientation of education itself should be considered comprehensively, and a strong market position should be established through image formation through external service factors, which are external environments of academies.Furthermore, in terms of presenting differentiated strategies with competitors, the educational service quality factors play a significant role in the commitment to the relationship with the students, so the role of relationship marketing will be important for the psychological stability experienced by the students by grasping the demand accompanying the behavior of the students in advance.