• Title/Summary/Keyword: image evaluation

Search Result 3,748, Processing Time 0.032 seconds

Digitization of Adjectives that Describe Facial Complexion to Evaluate Various Expressions of Skin Tone in Korean (피부색을 표현하는 형용사들의 수치화를 통한 안색 평가법 연구)

  • Lee, Sun Hwa;Lee, Jung Ah;Park, Sun Mi;Kim, Younghee;Jang, Yoon Jung;Kim, Bora;Kim, Nam Soo;Moon, Tae Kee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.349-355
    • /
    • 2017
  • Skin tone plays a key role in one of the determinant for facial attractiveness. Most female customers have an interest in choosing skin color and improving their skin tone and their needs have been contributed the expansion of cosmetic products in the market. Recently, cosmetic customers, who want bright skin, are also interested in healthy and lively-looking skin. However, there is no method to evaluate the skin tone with the complexion-describing adjectives (CDAs). Therefore, this study was conducted to find the ways to objectify and digitize the CDA. We obtained that quasi $L^*$ at dark skin is 65 and quasi $L^*$ at bright skin is 74 for standard images, which are selected from our data base. To match the following seven CDAs: pale, clear, radiant, lively, healthy, rosy and dull, the colors of both images were adjusted by 30 panels. The quasi $L^*$, $a^*$ and $b^*$ were converted from the RGB values of the manipulated images. The differences between the quasi $L^*$, $a^*$ and $b^*$ values of standard images and manipulated images reflecting each CDA were statistically significant (p < 0.05). However, there were no statistical significances between the $L^*$ values of dark and bright skin images that were modified in accordance with each CDA and there also were no statistical significances between the quasi $a^*$ values of dark and bright skin for pale and clear CDAs. From the statistical analysis, the CDAs were observed to form three groups: (i) pale-clear-radiant, (ii) lively-healthy-rosy and (iii) dull. We recognized that people have a similar opinion about perception of CDAs. Following our results of this study, we establish new standard method for sensibility evaluation which is difficult to carry out scientifically or objectively.

Causes of Under-staging in Patients with Gastric Cancer That was Proven to be Unresectable after a Laparotomy - Correlation with CT Findings (비절제 위암의 원인분석-전산화단층촬영(CT) 소견을 중심으로)

  • Yoon, Hyuk-Jin;Shin, Jung-Hye;Kim, Gab-Chul;Yu, Wan-Sik;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.263-269
    • /
    • 2006
  • Purpose: The aim of this study was to investigate the causes of under-staging in patients with advanced gastric cancer that was proven to be unresectable after a laparotomy. Materials and Methods: We retrospectively analyzed 25 gastric cancer patients who had undergone a diagnostic laparotomy between 2001 and 2005. For the preoperative evaluation, spiral CT and multidetector-row CT were performed. We analyzed the clinicopathologic features of patients and compared the image findings and the results of surgery. The causes of under-staging were divided into 3 groups; patient factor, CT factor, and interpretation factor. Results: Grossly, there were 12 cases of Borrmann type-III tumors and 13 cases of Borrmann type-IV tumors. The most frequent histologic type was poorly differentiated adenocarcinomas (8 cases) and signet ring cell carcinomas (7 cases). There were 13 cases of adjacent organ invasion, and the pancreas was the most frequently invaded organ (9 cases). There were 17 cases of peritoneal metastasis, and 3 cases of distant lymph node metastasis. For the cause of under-staging, there were four cases of patient factor, 19 cases of interpretation factor, and 9 cases of CT factor. In three cases, the cause of under-staging could not be identified. Conclusion: CT interpretation factor was the most frequent cause of under-staging in the preoperative diagnosis with gastric cancer patients. Therefore, more cautious CT interpretation is necessary to avoid unnecessary laparotomies in gastric cancer patients.

  • PDF

An Analysis of the Image and Visual Preference of a Light Rail Pier according to Aesthetic Styles (경전철 교각의 미관개선유형별 이미지 및 시각적 선호도 분석)

  • Jung, Sung-Gwan;Kang, Dong-Hyun;Shin, Jae-Yun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.15-26
    • /
    • 2015
  • The Daegu Metropolitan Transit Corporation Advisory Committee has chosen 5 styles of bridge-pier designs, including coating, graphic, planting, billboard and safety-facility style, based on the results of landscape simulations from a previous study. This study was conducted to investigate citizen's preferences and emotional images for each style of bridge-pier design, by aiming at the pilot urban landscape improvement section from Daebong Bridge in Suseong Gu to the crossroads near Dongseong Elementary School in Daegu Metropolitan City. The questionnaire was drawn up regarding the urban landscape improvement plans applied to the research area, and the questions were about citizens' perception of bridge-pier structures generated by constructing a light rail transit, important factors to consider when designing bridge piers, preferences for each style of bridge-pier design and emotional impact. 60.4% of the survey participants were found to perceive bridge-pier structures as unattractive, so it was necessary to improve them aesthetically. Regarding visual factors of bridge-pier designs, color was most important at 5.81, followed by form at 5.57. Regarding aesthetic component factors, harmony was most important at 6.07, followed by amenity at 6.00. In the survey participants' preference for each bridge-pier design, the graphic style was preferred most at 4.14, followed by the planting style. In emotional adjectives used for each bridge-pier design, the coating style, the safety-facility style and the non-treatment style showed similar results, and all of these styles were evaluated as artificial, lifeless and desolate. The graphic style and the billboard style showed different tendencies, depending on visual factors and aesthetic component factors applied to the graphic design used for these two bridge-pier styles. Since natural materials were used for the planting style, however, it showed high preference for such emotional images as natural and lively. The emotional adjective 'amiable' was found to affect citizens' preferences for each bridge-pier aesthetic improvement plan most, and it was also analyzed to have an effect on all the styles of bridge-pier designs. To improve the landscape of a light rail transit being constructed inside the urban area, this study quantitatively extracted citizens' preferences and emotional adjective for every style of bridge-pier design applied to the pilot urban landscape improvement section, and it is expected that the results of this study will be used as basic data to improve the landscape of bridge piers.

A Research on Service and Awareness of Dental Coordinators by Manpower at Dental Care Service Institutions - Centering on Manpower Other than Dentists (치과코디네이터 업무 및 인식에 관한 조사연구 - 치과의사를 제외한 기타 인력을 중심으로)

  • Choi, Boo-Keun;Han, Su-Jin;Kwon, Soon-Bok;Jung, Jae-Yeon;Cho, Myung-Sook;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.6 no.4
    • /
    • pp.437-453
    • /
    • 2006
  • To analyze dental hygienists and other manpower at dental care service institutions where a dental coordinator was working among about 200 dental care service institutions in Seoul, Gyeonggi Province, and Incheon as of June 2005 for contents of training for dental coordinators, opinions of qualification of dental coordinators, present and future services provided by dental coordinators, and awareness of dental coordinators and to provide basic data about future services, roles, and cultivation of dental coordinators, a survey was conducted and 216 copies returned were analyzed, obtaining the following results. 1. 83.8 percent needed an educational program for dental coordinators as an educational content; 41.7% had awareness of the educational content; and 83.8 percent insisted that over the intermediate level of curricula should be taken. Dental coordinator cultivation institutions identified included the institution under the control of the Korean Dental Hygienists Association and the education center for the department of dental hygiene; 76.9% insisted that an appropriate qualifying examination should be necessary. They suggested the central government department and the local government as a certification institution; 39.4% insisted that financial support for the education should be provided by financing education alone. Only 28.7% experienced dental coordinator education and 73.1% hoped to serve as a dental coordinator. They were found to expect a rise in payment(64.4%) and in the title(46.8%) after completion of the educational program. 2. 66.2% saw a dental hygienist as the most appropriate for a dental coordinator; clinical career (39.4%) and practical capacity(29.2%) were suggested as requirements for a dental coordinator; and a period of over three years(47.2%) was suggested for appropriate dental career. 3. Dental coordinators' present services included 'reservation management' for customer management, 'staff service training' for organization management, 'understanding of customer reception attitudes and actions' for self-management, 'hospital information management' for hospital marketing, 'acceptance' for hospital affairs management, and 'hospital environment management' for hospital facilities management; their future services included 'acquisition of ability to use a foreign language' for self-management, followed by 'staff service training' for organization management, 'training and counseling' for customer management, 'acquisition of counseling capacity' for self-management, 'complaining customer reception' for customer management, and 'marketing strategy implementation' for hospital marketing. 4. After comparing dental hygienists and other manpower in terms of dental coordinators' future services, dental hygienists showed interest in 'acquisition of ability to use a foreign language,' 'staff service training,' 'complaining customer reception,' and 'acquisition of counseling capacity' while other manpower showed interest in 'acquisition of ability to use a foreign language,' 'document data management,' 'acquisition of basic service manner,' 'acquisition of counseling capacity,' 'manpower management,' 'establishment and evaluation of a marketing strategy,' and 'education and counseling.' 5. As for awareness of dental coordinators, they were thought of as helpful in improving image of a dental clinic; it was found that continuous training should be necessary to develop dental coordinators' capacity; dental coordinators' services should be important and contribute to patients' qualitative satisfaction.

  • PDF

Designing Mobile Framework for Intelligent Personalized Marketing Service in Interactive Exhibition Space (인터랙티브 전시 환경에서 개인화 마케팅 서비스를 위한 모바일 프레임워크 설계)

  • Bae, Jong-Hwan;Sho, Su-Hwan;Choi, Lee-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.1
    • /
    • pp.59-69
    • /
    • 2012
  • As exhibition industry, which is a part of 17 new growth engines of the government, is related to other industries such as tourism, transportation and financial industries. So it has a significant ripple effect on other industries. Exhibition is a knowledge-intensive, eco-friendly and high value-added Industry. Over 13,000 exhibitions are held every year around the world which contributes to getting foreign currency. Exhibition industry is closely related with culture and tourism and could be utilized as local and national development strategies and improve national brand image as well. Many countries try various efforts to invigorate exhibition industry by arranging related laws and support system. In Korea, more than 200 exhibitions are being held every year, but only 2~3 exhibitions are hosted with over 400 exhibitors and except these exhibitions most exhibitions have few foreign exhibitors. The main reason of weakness of domestic trade show is that there are no agencies managing exhibitionrelated statistics and there is no specific and reliable evaluation. This might cause impossibility of providing buyer or seller with reliable data, poor growth of exhibitions in terms of quality and thus service quality of trade shows cannot be improved. Hosting a lot of visitors (Public/Buyer/Exhibitor) is very crucial to the development of domestic exhibition industry. In order to attract many visitors, service quality of exhibition and visitor's satisfaction should be enhanced. For this purpose, a variety of real-time customized services through digital media and the services for creating new customers and retaining existing customers should be provided. In addition, by providing visitors with personalized information services they could manage their time and space efficiently avoiding the complexity of exhibition space. Exhibition industry can have competitiveness and industrial foundation through building up exhibition-related statistics, creating new information and enhancing research ability. Therefore, this paper deals with customized service with visitor's smart-phone at the exhibition space and designing mobile framework which enables exhibition devices to interact with other devices. Mobile server framework is composed of three different systems; multi-server interaction, server, client, display device. By making knowledge pool of exhibition environment, the accumulated data for each visitor can be provided as personalized service. In addition, based on the reaction of visitors each of all information is utilized as customized information and so the cyclic chain structure is designed. Multiple interaction server is designed to have functions of event handling, interaction process between exhibition device and visitor's smart-phone and data management. Client is an application processed by visitor's smart-phone and could be driven on a variety of platforms. Client functions as interface representing customized service for individual visitors and event input and output for simultaneous participation. Exhibition device consists of display system to show visitors contents and information, interaction input-output system to receive event from visitors and input toward action and finally the control system to connect above two systems. The proposed mobile framework in this paper provides individual visitors with customized and active services using their information profile and advanced Knowledge. In addition, user participation service is suggested as well by using interaction connection system between server, client, and exhibition devices. Suggested mobile framework is a technology which could be applied to culture industry such as performance, show and exhibition. Thus, this builds up the foundation to improve visitor's participation in exhibition and bring about development of exhibition industry by raising visitor's interest.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes (토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가)

  • Minar, Maruf;Hwang, Ya-won;Choi, Seok-hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The aim of the study was to assess the in vitro effect of 808-nm InGaAs diode laser on rabbit articular chondrocyte proliferation and sulphated glycosaminoglycan (sGAG) synthesis in alginate bead. Previous studies revealed either positive or negative stimulatory effects of laser on different types of cells. A 808-nm InGaAs diode laser at 1.0W power output was used to irradiate the rabbit chondrocytes in alginate beads with energy densities of $31J/cm^2$ (G 1) and $62J/cm^2$ (G 2) corresponding to the experimental groups for 10 seconds and 20 seconds, respectively at 24, 48, 72 and 96 hours after seeding. Control group was left untreated. MTT assay was performed at 1 week and 2 weeks after the $1^{st}$ laser irradiation in alginate beads. sGAG synthesis in alginate beads at 1 week and 2 weeks were determined by DMMB assay. Histological evaluation for cellular distribution and sGAG deposition around the cells were performed by alcian blue stain. MTT assay revealed no positive stimulatory effect in cell proliferation in alginate bead. DMMB assay results showed significantly increased sGAG production in G 2 chondrocytes at 2 weeks. Image analysis of alcian blue stained slides also showed significantly higher percentage of positive alcian blue stain in G 2 chondrocytes. This result suggests that 808-nm InGaAs diode laser with 1.0 W power output although cannot stimulate cell proliferation it can increase the cell secretion activity and sGAG deposition in alginate beads.