• Title/Summary/Keyword: illuminating power

Search Result 1,299, Processing Time 0.024 seconds

Control Scheme of Emergency Power Supply for Elevator Emergency Call System (승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로)

  • Park, Noh-Sik;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

A Study on the Development and the Application of Reducdant Digital Excitation System for the Power Plants (다중화 디지털 여자 시스템 개발과 발전소 적용에 관한 연구)

  • 김경철;임익헌
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.97-107
    • /
    • 2001
  • Many power plants in the thermal and hydraulic utilities, the pulp and the paper industry are faced with high maintenance and down time due to the aged excitation system. For the life extension of the aged power plants, the static excitation system of triple module redundancy type had been developed by KEPRI(Korea Electric Power Research Institute). This paper will discuss the design conception and the application results of system which includes the power control devices(thyristors, GTO), power potential transformer(excitation transformer) and triple module redundancy controller(voltage regulator).

  • PDF

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

A Study on the AC Pow a Study on the AC Power Control Circuit by Combining PWM and Phase Control (PWM과 입상제어의 조합에 의한 교류전력 제어회로에 관한 연구)

  • 정화균;김이곤;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.84-95
    • /
    • 1991
  • Mostly, phase control method is used to control the single phase AC power. The phase control method has some advantages such as ease to control and simple configuration. But the retardation of firing angle causes a lagging current even if load is purely resistive. So phase control causes a lagging power factor and a low efficiency at the input side in comparing with the system without switching device. A new PWM control method which can improve these defects for single phase AC power control circuit is proposed in this paper. The performances of the single phase AC power control circuit using the proposed method was investigated theoretically. Both power factor and waveform of load current can be improved better than those of the conventional methods.

  • PDF

Improvement of Power Spectrum in Ultrashort Pulse Reflectometry Signals Using Three Chirp Configuration

  • Roh, Young-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.51-56
    • /
    • 2014
  • The flat power spectrum of the transmitter output signal for the desired frequency range is ideal to achieve the best performance of ultrashort pulse reflectometry. However, the power spectrum of a typical pulse generator decreases significantly as frequency increases. A configuration of three chirped waveforms was employed to improve the power spectrum of the transmitter signal at higher frequencies. To determine the amplification gain required for higher frequency components, three chirped waveforms were theoretically generated and their power spectra were measured using numerical band-pass filters. Based on the results of numerical computations, the three chirp configuration was successfully applied to the design of the transmitter for a broadband system.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

A Study on Generator Temperature and Power Converter Efficiency according to change of Wind Velocity (풍속 변화에 따른 발전기 온도 및 전력변환장치 효율에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.8-13
    • /
    • 2015
  • Recently, because a renewable power source must operate as a constant rate in accordance with RPS(Renewable Portfolio Standard), the study of the renewable power sources has been ongoing. Especially because of noise of wind turbine, troubleshooting, and urban greening business, research related with small wind turbine are underway. The economics and reliability are important parts for the activation of small wind turbine, such as solar energy. In this paper, by analyzing the temperature variations for each location and efficiency of power conversion devices in accordance with short period wind speed changes in simulation test, we reviewed the safety about temperature variations of wind generator and the method of selection of power converter.

Development of Countermeasure for Improving the Power Quality using Coordinated Control of BESS on Electric Vehicle connected System (전기 자동차 계통 연계 시 BESS의 협조제어를 이용한 전력품질 향상 대책 개발)

  • Lee, Soon-Jeong;Kim, Sang-Won;Kim, Jun-Hyeok;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.63-69
    • /
    • 2015
  • Energy Storage Systems (ESSs) are essential in the future power systems because they can improve power usage efficiency. In this paper, we propose the countermeasure for improving the power quality using coordinated control of BESS(Battery Energy Storage System) on EV connected system. To verify the performance of proposed scheme, we simulate on the actual power system of KEPCO and compare the results of voltage variation, frequency variation, and load factor with those of uncoordinated control. From the simulation results, we confirm that frequency and voltage deviation are significantly reduced with proposed coordinated control of BESS.

Elevator's Car Auxiliary Power System using the Contactless Power Transmission Method (비접촉 전력전송방식을 이용한 엘리베이터 카 보조 전원시스템)

  • Lim, Eung-Kyu;Rho, Sung-Chan;Kim, Soo-Hong;Kim, Ji-Min;Kim, Youn-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.80-84
    • /
    • 2008
  • In this paper, we have posed contactless power supply method using the contactless transformer with multiple primary winding. Also, the system uses resonant frequency tracking method for safe power supply at the elevator's car. The proposed system has been verified by the simulation using ICA4 and Maxwell. The contactless power transmission system is designed for 5[kW] rate.

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.