• Title/Summary/Keyword: ignition switch

Search Result 19, Processing Time 0.028 seconds

Studies on MEMS Inertial Switch Applicable to the Ignition SAU(Safe-Arm-Unit) of Propulsion System (추진기관 점화안전장치에 적용 가능한 MEMS 관성 스위치 연구)

  • Jang, Seung-Gyo;Jung, Hyung-Gyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.126-129
    • /
    • 2010
  • MEMS(micro electro-mechanical systems) inertial switch which is applicable to the ignition Safe-Arm- Unit of propulsion system is devised. The MEMS inertial switch is designed according to the general design procedure for conventional mechanical elements. Unlikely conventional MEMS accelerometer, threshold inertial switching mechanism is adopted which makes a MEMS element an abrupt switching in a certain acceleration level. By comparing the design data and test results of the specimen a small discrepancy in switching acceleration level is found which is presumably due to the nonlinear characteristics of the beam spring and the flexure hinge which are the main parts of the MEMS inertial switch.

  • PDF

Re-ignition System using Vacuum Triggered Gap-switch for Synthetic Breaking Test

  • Park Seung-Jae;Suh Yoon-Taek;Kim Dae-Won;Kim Maeng-Hyun;Song Won-Pyo;Koh Hee-Seog
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.145-151
    • /
    • 2005
  • The synthetic breaking test method was developed to evaluate the breaking performance of ultra high-voltage circuit breaker and made up of two independent circuits; current source circuit and voltage source circuit. In application of this test method, it is necessary to extend the arc of the test breaker. So, the new re-ignition system using VTGS (Vacuum Triggered Gap-Switch) was constructed to improve the efficiency and reliability of this test. In this re-ignition system, VTGS operates in high vacuum state of $5{\time}10^{17}$torr and control system consists of the triggering device and the air M-G (Motor-Generator). This re-ignition system showed the operating characteristics, such as delay time ($t_d$) and jitter time ($t_j$ not exceeding 5us and 1us respectively, and had the operating voltage of $25\~150kVdc$ at the gap distance of 24mm.

Switch Circuit Design in 0.18㎛ BCDMOS for Small Form Factor Automotive Smart Junction Box (자동차 스마트 정션 박스 소형화를 위한 0.18㎛ BCDMOS 기반 스위치 회로 설계)

  • Lee, Ukjun;Kwon, Geono;Lim, Hansang;Shin, Hyunchol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.82-88
    • /
    • 2015
  • This paper presents a design of the enable switch circuit, which is consist of discrete device at smart junction box(SJB) board. The Enable switch circuit, which receives ignition signal (IG) for input, sends a drive signal to linear regulator and other elements. The circuit design is carried out in a BCDMOS $0.18{\mu}m$ technology, and the performances are verified through simulations according to AEC-Q100 and ISO 7637-2. Die area of the designed Enable switch circuit is $1.67mm{\times}0.54mm$ in layout, and it is shown that the die can be housed in $3mm{\times}3mm$ HVSON8 package. The designed enable switch circuit is expected to be widely adopted in various automotive SJB's since it can significantly reduce the overall printed circuit board form factor.

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Ignition Safe-Arm-Unit Using Micro-Electromechanical Systems (MEMS를 이용한 추진기관 점화안전장치)

  • Jang, Seung-Gyo;Lee, Sang-Hun;Chang, Hyun-Kee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.282-285
    • /
    • 2009
  • Ignition Safe-Arm-Unit using micro-electromechanical systems(MEMS) for propulsion system was designed and manufactured. MEMS was designed according to the design schemes for conventional mechanical elements. By comparing the design results and the test data of the prototype, small discrepancy was found, which is due to the nonlinear characteristic of the structure and the machining accuracy. The applicability of MEMS for Safe-Arm-Unit was proved by testing MEMS which is assembled into SAU.

  • PDF

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

A Electronic Starter for Fluorescent Lamps for use as Neon Signs (네온사인 기능을 수행하는 형광램프용 전자식 스타터)

  • 송상빈;곽재영;여인선;임건호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.228-233
    • /
    • 1999
  • In this paper we develop an electronic starter circuit that is suitable for Neon sign operation of switch-start fluorescent lamps. The developed starter enable single pulse ignition of fluorescent lamp at the peak point of preheating current, irrespective of the position of the Tum-On signal. This is possible due to the sequential operation of two transistors different in their operation characteristics and a diode operation characteristic. The switching endurance test using this starter has been carried for more than 3000 hours for a single switch-start on a severe blinking condition of preheating of 0.1s and of successive lighting interval of 0.1s.

  • PDF

Fire Characteristics of Circuit Breakers for Low Voltage during Switching Arcs according to the Characteristics of Combustibles (가연물 특성에 따른 저압용 차단기의 스위치 아크에 의한 화재특성)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.37-38
    • /
    • 2006
  • In this paper, the fire characteristics of circuit breakers for low voltage during switching arcs were analyzed according to the characteristics of combustible materials. Arc dispersion and ignition process were taken by high speed imaging system and digital camera. In this experiment, four resistors were connected as loads. To discover the fire characteristics of circuit breakers by combustible materials, ethanol and cotton were installed as combustibles near contacts respectively. In case of ethanol, fire broke out near the contacts while switch was turned on and turned off. Whereas, in case of cotton, fire broke out near deteriorated contacts while switch was turned off.

  • PDF

A case study on usability analysis a car interior I (자동차 인테리어의 사용성 분석에 관한 사례연구I ­운전석을 중심으로­)

  • 양수선;김병길;김철수;박영목;박종서
    • Proceedings of the Korea Society of Design Studies Conference
    • /
    • 2000.11a
    • /
    • pp.8-9
    • /
    • 2000
  • 기존의 자동차 인테리어 디자인은 인간공학적이나 스타일링을 위주로 하는 경우가 많았다. 그러나 본 연구는 운전자의 '사용성' 이라는 측면에서 운전부를 중심으로 운행에 관계된 이그니션콘트롤(ignition control), 멀티펑션스위치(multi function switch)와 차량의 상태를 알려주는 클러스터게이지(cluster gauge)를 중심으로 조사해 보았다. (중략)

  • PDF

Study on Wear of Journal Bearings during Start-up and Coast-down Cycles of a Motoring Engine - II. Analysis Results (모터링 엔진의 시동 사이클 및 시동 정지 사이클에서 저어널베어링의 마모 연구 - II. 해석 결과)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.125-140
    • /
    • 2015
  • In this paper, we present the results of the wear analysis of journal bearings on a stripped-down single-cylinder engine during start-up and coast-down by motoring. We calculate journal bearing wear by using a modified specific wear rate considering the fractional film defect coefficient and load-sharing ratio for the asperity portion of a mixed elastohydrodynamic lubrication (EHL) regime coupled with previously presented graphical data of experimental lifetime linear wear in radial journal bearings. Based on the calculated wear depth, we obtain a new oil film thickness for every crank angle. By examination of the oil film thickness, we determine whether the oil film thickness at the wear scar region is in a mixed lubrication regime by comparing dimensionless oil film thickness, h/σ, to 3.0 at every crank angle. We present the lift-off speed and the crank angles involved with the wear calculation for bearings #1 and #2. The dimensionless oil film thickness, h/σ, illustrates whether the lubrication region between the two surfaces is still within the bounds of the mixed lubrication regime after scarring of the surface by wear. In addition, we present in tables the asperity contact pressure, the real minimum film thickness at the wear scar region, the modified specific wear rate, and the wear angle, α, for bearings #1 & #2. To show the real shape of the oil film at wear scar region, we depict the actual oil film thickness in graphs. We also tabulated the ranges of bearing angles related with wear scar. We present the wear volume for bearings #1 and #2 after one turn-on and turn-off of the engine ignition switch for five kinds of equivalent surface roughness. We show that the accumulated wear volume after a single turn-on and turn-off of an ignition switch normally increases with increasing surface roughness, with a few exceptions.